Apply to be a TradeMaster!
Filter menu expanded

Filters

463,427 items
Reset

SORT

Wilo Z-15 Pump Parts

Help Face
Need a little help?
463427 items
Grid
List
Compare
Product Image of 1/2" Npt Bronze Strnr .045perf, D515092
$289.05 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of Repair Cap 213 1/2 Npt, D569243
$269.13 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of Repair Body 880 1/2 Npt, D584267
$185.31 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of Thermostatic Wafer Trap 3/8", D541398
$415.56 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of Valve Seat And Stem, D563886
$699.25 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of 1/2" Thermostatic Limiter, D56577
$728.09 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of 3/4" Trap Valve Station 30#, D588550
$675.08 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of 5" Round Chrome Plated Strainer w/ 3-1/2" Metal Spud
$112.42 each
In Stock
Get 1 by Tomorrow, Nov 25
In Stock
Get 1 by Tomorrow, Nov 25
Compare
Product Image of 32 RMX Service Pack, D11581
$128.36 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of Lantern Rg Coil Ptfe 3/8x1/2
Lantern Rg Coil Ptfe 3/8x1/2
SKU: D118030-300
Armstrong Pumps
SKU: D118030-300
$47.86 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of Lantern Ring (each)
Lantern Ring (each)
SKU: D118035-000
Armstrong Pumps
SKU: D118035-000
$139.58 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of D1CS090E04046A Parts - Packaged Unit/RTUnot-to-sell-product
D1CS090E04046A Parts - Packaged Unit/RTU
SKU: D1CS090E04046A
York
SKU: D1CS090E04046A
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of D1CS120E01046A Parts - Packaged Unit/RTUnot-to-sell-product
D1CS120E01046A Parts - Packaged Unit/RTU
SKU: D1CS120E01046A
York
SKU: D1CS120E01046A
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of D1CS120E02025A Parts - Packaged Unit/RTUnot-to-sell-product
D1CS120E02025A Parts - Packaged Unit/RTU
SKU: D1CS120E02025A
York
SKU: D1CS120E02025A
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of Dual-Gang Stainless Steel Duraport, Industrial Wallplate, 2-port
$31.32 each
Out of Stock
Get it by Thu, Dec 10 - Thu, Dec 17
Out of Stock
Get it by Thu, Dec 10 - Thu, Dec 17
Compare
Product Image of Dual-Gang Stainless Steel Duraport, Industrial Wallplate, 4-port
$31.32 each
Out of Stock
Get it by Thu, Dec 10 - Thu, Dec 17
Out of Stock
Get it by Thu, Dec 10 - Thu, Dec 17
Compare
Product Image of DAYP-F036N070A/05-2002 Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
DAYP-F036N070A/05-2002 Parts - Coleman Packaged Unit/Rooftop Unit
SKU: DAYP-F036N070A/05-2002
Coleman
SKU: DAYP-F036N070A/05-2002
Brand: Coleman
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DAYP-F048N135A Parts - York Central Air Conditionernot-to-sell-product
DAYP-F048N135A Parts - York Central Air Conditioner
SKU: DAYP-F048N135A
York
SKU: DAYP-F048N135A
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DAYP-T036N090A Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
DAYP-T036N090A Parts - Coleman Packaged Unit/Rooftop Unit
SKU: DAYP-T036N090A
Coleman
SKU: DAYP-T036N090A
Brand: Coleman
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DAYP-T042N080A Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
DAYP-T042N080A Parts - Coleman Packaged Unit/Rooftop Unit
SKU: DAYP-T042N080A
Coleman
SKU: DAYP-T042N080A
Brand: Coleman
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of 5 Gallon Tankless Coil for Trianco Boilers
$705.36 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of DAYH-X042N110C Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
DAYH-X042N110C Parts - Coleman Packaged Unit/Rooftop Unit
SKU: DAYH-X042N110C
Coleman
SKU: DAYH-X042N110C
Brand: Coleman
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DAYH-X060N110C Parts - Packaged Unit/RTUnot-to-sell-product
DAYH-X060N110C Parts - Packaged Unit/RTU
SKU: DAYH-X060N110C
York
SKU: DAYH-X060N110C
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of D1NP030N03606NX Parts - York Central Air Conditionernot-to-sell-product
D1NP030N03606NX Parts - York Central Air Conditioner
SKU: D1NP030N03606NX
York
SKU: D1NP030N03606NX
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of D1NP042N06546 Parts - Packaged Unit/RTUnot-to-sell-product
D1NP042N06546 Parts - Packaged Unit/RTU
SKU: D1NP042N06546
York
SKU: D1NP042N06546
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of D1NP048N06506A Parts - Packaged Unit/RTUnot-to-sell-product
D1NP048N06506A Parts - Packaged Unit/RTU
SKU: D1NP048N06506A
York
SKU: D1NP048N06506A
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of D1NP048N06558 Parts - Packaged Unit/RTUnot-to-sell-product
D1NP048N06558 Parts - Packaged Unit/RTU
SKU: D1NP048N06558
York
SKU: D1NP048N06558
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of D1NP048N09025A Parts - Packaged Unit/RTUnot-to-sell-product
D1NP048N09025A Parts - Packaged Unit/RTU
SKU: D1NP048N09025A
York
SKU: D1NP048N09025A
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of Lv-4w Thermostatopw/16.5'sens, D24665
$523.63 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of DB6 Series Dura-Blok Rooftop Support (6-7/16" x 6" x 9.6")
$63.77 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of 14" DBA Duct Board Adapter (2 PK)
$36.57 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of 22" DBA Duct Board Adapter (2 PK)
$41.34 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of 10" x 18" Danger Hard Hats Required in This Area Bilingual, DBA4R
$15.46 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of 10" High Danger No Smoking Plastic Sign, DBA6R
$15.46 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of 10" High Danger Pinch Points Vinyl Sign, DBA9P
$15.37 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of DBC0363D000001S Parts - Daikin Light Commercial Packaged Air Conditionernot-to-sell-product
Out of Stock
Get it by Thu, Dec 10 - Thu, Dec 17
Out of Stock
Get it by Thu, Dec 10 - Thu, Dec 17
Compare
Product Image of DAYP-T036N045A/05-2002 Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
DAYP-T036N045A/05-2002 Parts - Coleman Packaged Unit/Rooftop Unit
SKU: DAYP-T036N045A/05-2002
Coleman
SKU: DAYP-T036N045A/05-2002
Brand: Coleman
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DAYP-T036N070 Parts - Packaged Unit/RTUnot-to-sell-product
DAYP-T036N070 Parts - Packaged Unit/RTU
SKU: DAYP-T036N070
York
SKU: DAYP-T036N070
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DAYP-W036N090A/05-2002 Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
DAYP-W036N090A/05-2002 Parts - Coleman Packaged Unit/Rooftop Unit
SKU: DAYP-W036N090A/05-2002
Coleman
SKU: DAYP-W036N090A/05-2002
Brand: Coleman
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DAYZ-F030N070A Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
DAYZ-F030N070A Parts - Coleman Packaged Unit/Rooftop Unit
SKU: DAYZ-F030N070A
Coleman
SKU: DAYZ-F030N070A
Brand: Coleman
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of D1NQ036N05646NX Parts - Packaged Unit/RTUnot-to-sell-product
D1NQ036N05646NX Parts - Packaged Unit/RTU
SKU: D1NQ036N05646NX
York
SKU: D1NQ036N05646NX
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of D1NQ042N06525NX Parts - Packaged Unit/RTUnot-to-sell-product
D1NQ042N06525NX Parts - Packaged Unit/RTU
SKU: D1NQ042N06525NX
York
SKU: D1NQ042N06525NX
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of D1NQ042N06546 Parts - Packaged Unit/RTUnot-to-sell-product
D1NQ042N06546 Parts - Packaged Unit/RTU
SKU: D1NQ042N06546
York
SKU: D1NQ042N06546
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of 14" High Danger Construction Site No Trespassing Plastic Sign, D248RC
$21.88 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of DBC0484B000001SAA Parts - Daikin Light Commercial Packaged Air Conditioner, Single Stagenot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DBC2403SAA Parts - Daikin Light Commercial Packaged Air Conditioner, Single Stagenot-to-sell-product
DBC2403SAA Parts - Daikin Light Commercial Packaged Air Conditioner, Single Stage
SKU: DBC2403SAA
Daikin
SKU: DBC2403SAA
Brand: Daikin
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DAYZ-W048N110A Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
DAYZ-W048N110A Parts - Coleman Packaged Unit/Rooftop Unit
SKU: DAYZ-W048N110A
Coleman
SKU: DAYZ-W048N110A
Brand: Coleman
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of D1NQ060N09025NX Parts - Packaged Unit/RTUnot-to-sell-product
D1NQ060N09025NX Parts - Packaged Unit/RTU
SKU: D1NQ060N09025NX
York
SKU: D1NQ060N09025NX
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Resources
FAQs, Manuals & Videos
Articles
More About Wilo Z-15 Pump Parts

Wilo Z-15 pump parts are the replacement components contractors use to service and rebuild Z-15 wet-rotor circulator pumps found in residential and light commercial hydronic heating and hot water recirculation systems. The Z-15 is a single-speed, in-line circulator, and its most commonly replaced parts are the pump head, rotor and impeller assembly, and the mounting gaskets that seal the pump body to the piping flanges. Over years of continuous operation, mineral buildup and worn bearings inside the wet-rotor cartridge are the usual reasons a Z-15 needs a rebuild rather than a full replacement. Keeping gaskets, cartridges, and mounting hardware on hand lets a contractor return a system to service the same day instead of waiting on a full pump swap, which matters most on boiler systems where extended downtime affects a building's heat.

Subcategories

  • Pump Heads: Pump heads house the motor and electrical connections for the Z-15 circulator and bolt directly onto the wet-rotor cartridge below. Contractors replace a pump head when the motor windings fail or a bad capacitor stops the rotor from starting, rather than swapping the entire unit. Because the head separates from the wet end without draining the whole system in most installations, it's often the fastest single-part repair on a Z-15. Matching the voltage and speed rating to the original nameplate keeps the replacement head compatible with the existing wiring.
  • Rotor & Impeller Assemblies: The rotor and impeller assembly is the wet-rotor cartridge that spins inside the pump body to move water through the system. Mineral scale and sediment are the most common causes of a sluggish or seized rotor, especially in older cast iron hydronic loops. Replacing the assembly restores full flow without needing to replace the pump housing or motor head. A worn sleeve bearing inside the assembly is usually what causes the humming or grinding noise contractors hear before a Z-15 fails outright.
  • Mounting Gaskets & Flanges: Mounting gaskets seal the pump body against the flanges that connect it to the supply and return piping. A worn or improperly seated gasket is one of the most common sources of a slow weep leak at the pump union. Flanges themselves rarely need replacement unless they've been damaged during a prior installation or corroded from years of exposure to boiler water. Keeping the correct gasket size on hand avoids a return trip when a routine pump service uncovers a leak at the union.
  • Cartridge Seal Kits: Cartridge seal kits bundle the O-rings and shaft seals needed to reseal the wet-rotor cartridge after it's opened for cleaning or bearing replacement. Using a complete kit instead of individual seals reduces the chance of missing a small O-ring that causes a repeat callback. Seal kits are typically sized to the specific cartridge generation, so matching the kit to the pump's production era matters more than matching it to the overall Z-15 model name alone. A fresh seal kit is standard practice any time the cartridge is removed for service, even if the old seals look intact.
  • Buying Guide

    When sourcing Wilo Z-15 pump parts, start with the failure symptom rather than guessing at a full parts list. A pump that hums but doesn't spin usually points to a seized rotor or worn bearing, calling for a rotor and impeller assembly rather than a new pump head. A pump that won't start electrically, or trips a breaker, more often points to the motor windings or capacitor inside the pump head itself. Confirm the exact age and cartridge generation of the installed unit before ordering, since Wilo has updated the internal cartridge design over the years and parts from a newer cartridge don't always fit an older pump body. For jobs where the pump has been in continuous service for many years, rebuilding with a full cartridge seal kit alongside the rotor assembly is often more efficient than replacing components piecemeal, since it addresses wear across the whole wet end in one visit. Keep a small stock of the most commonly needed Wilo Z-15 pump parts, gaskets, seal kits, and a spare pump head, on hand for routine hydronic service calls, since these are the components most likely to fail from years of continuous operation. For a pump that's failed catastrophically or is several rebuilds in already, replacing the entire unit is often the more practical long-term choice over continuing to source individual parts.

    Frequently Asked Questions

    How do I know if my Wilo Z-15 needs a new pump head or a full rotor assembly?

    If the pump is silent and doesn't spin at all, check the motor head first, since that usually points to a failed capacitor or burned winding. If the pump hums or vibrates but the rotor won't turn, the wet-rotor cartridge itself is more likely the problem. Testing continuity at the motor terminals before ordering parts helps confirm which component actually failed.

    Can I rebuild a Z-15 without draining the whole heating system?

    In most installations, the pump head separates from the wet-rotor cartridge without opening the main piping, so a motor swap doesn't require draining the loop. Replacing the cartridge, gaskets, or flanges does require isolating and draining the pump section, though the rest of the system can often stay filled if isolation valves are present. Always confirm the specific installation has isolation valves before promising a no-drain repair.

    Why does my Z-15 keep leaking at the union even after a new gasket?

    A repeat leak after a gasket replacement is usually a sign the flange itself is corroded, warped, or wasn't torqued evenly during installation. Overtightening a new gasket can also distort it and cause the same leak to return. Checking the flange surface for pitting and torquing bolts in a cross pattern typically resolves a recurring union leak.

    How long does a Z-15 cartridge seal kit typically last?

    Seal life depends heavily on water quality and how often the system cycles, so there's no single fixed interval for every installation. Systems with harder water or more mineral content tend to wear seals faster than closed loops with treated water. Replacing the seal kit any time the cartridge is opened for service, rather than waiting for a visible leak, helps avoid a repeat callback.

    Is it worth rebuilding an older Z-15 or should I replace the whole pump?

    A rebuild makes sense when the pump body and flanges are still in good condition and only the wet-rotor cartridge or motor head has failed. Once a pump has needed several rebuilds over a short period, or the housing itself shows corrosion, replacing the entire unit is usually the more practical option. Weighing the age of the installation against the parts already on hand helps make that call quickly during a service visit.