Apply to be a TradeMaster!
Filter menu expanded

Filters

463,427 items
Reset

SORT

Wilo Z-15 Pump Parts

Help Face
Need a little help?
463427 items
Grid
List
Compare
Product Image of DBC0484B000001SAA Parts - Daikin Light Commercial Packaged Air Conditioner, Single Stagenot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DBC2403SAA Parts - Daikin Light Commercial Packaged Air Conditioner, Single Stagenot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DAYZ-W048N110A Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
DAYZ-W048N110A Parts - Coleman Packaged Unit/Rooftop Unit
SKU: DAYZ-W048N110A
Coleman
SKU: DAYZ-W048N110A
Brand: Coleman
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of D1NQ060N09025NX Parts - Packaged Unit/RTUnot-to-sell-product
D1NQ060N09025NX Parts - Packaged Unit/RTU
SKU: D1NQ060N09025NX
York
SKU: D1NQ060N09025NX
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of D1NS036N08006B Parts - Packaged Unit/RTUnot-to-sell-product
D1NS036N08006B Parts - Packaged Unit/RTU
SKU: D1NS036N08006B
York
SKU: D1NS036N08006B
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of Impeller Locknut "l"
Impeller Locknut "l"
SKU: D251892-041
Armstrong Pumps
SKU: D251892-041
$618.50 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of Shaft 416 Stainless Steel
Shaft 416 Stainless Steel
SKU: D251904-071
Armstrong Pumps
SKU: D251904-071
$2,256.32 each
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of Stuffing Box Extension Gasket
Stuffing Box Extension Gasket
SKU: D251921-000
Armstrong Pumps
SKU: D251921-000
$8.30 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of Gasket, Parting Flange 5x4x10
Gasket, Parting Flange 5x4x10
SKU: D251922-001
Armstrong Pumps
SKU: D251922-001
$49.63 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of Gasket, Parting Flange 12x10x12.5
Gasket, Parting Flange 12x10x12.5
SKU: D251932-001
Armstrong Pumps
SKU: D251932-001
$51.44 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of Casing Gasket, D251939-001
Casing Gasket, D251939-001
SKU: D251939-001
Armstrong Pumps
SKU: D251939-001
$378.40 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of DBC2407S Parts - Daikin Light Commercial Packaged Air Conditionernot-to-sell-product
Out of Stock
Get it by Thu, Dec 10 - Thu, Dec 17
Out of Stock
Get it by Thu, Dec 10 - Thu, Dec 17
Compare
Product Image of 1/4" Aluminum Handle Bit Driver and Insert Bit Set with Case, 38-Piece
$40.00 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of 10" High Danger Pinch Points Plastic Sign, DBA9R
$15.46 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of DBC0367B000001SAA Parts - Daikin Light Commercial Packaged Air Conditioner, Single Stagenot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DBC1807VDDCAA Parts - Daikin Light Commercial Packaged Air Conditionernot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DBC2403VAA Parts - Daikin Light Commercial Packaged Air Conditioner, Single Stagenot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of D1SE018N04306 Parts - York Central Air Conditionernot-to-sell-product
D1SE018N04306 Parts - York Central Air Conditioner
SKU: D1SE018N04306
York
SKU: D1SE018N04306
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of D1SE060N08525 Parts - York Central Air Conditionernot-to-sell-product
D1SE060N08525 Parts - York Central Air Conditioner
SKU: D1SE060N08525
York
SKU: D1SE060N08525
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of Gp-1000 Main Valve Kit,1/2&3/4, D25366
$489.07 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of JK23 3-Phase ODP General Purpose Motor, 324T Frame (230V, 25 HP, 1185 RPM), D25V3B
$3,792.93 each
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DBG0363C800001FAA Parts - Daikin Light Commercial Packaged Gas/Electric, Single Stagenot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DBG0364CL00001F Parts - Daikin DBG Series Gas/Electric Packaged Rooftop Unit (RTU)not-to-sell-product
Out of Stock
Get it by Thu, Dec 10 - Thu, Dec 17
Out of Stock
Get it by Thu, Dec 10 - Thu, Dec 17
Compare
Product Image of DBG0483CM00001FAA Parts - Daikin Light Commercial Packaged Gas/Electric, Single Stagenot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of JA40 3-Phase ODP General Purpose Motor, 445T Frame (460V, 200 HP, 1785 RPM), D200V2C
$16,347.05 each
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of HE68 3-Phase ODP General Purpose Motor, 254T Frame (200V, 20 HP, 3540 RPM), D20P1H
$2,036.46 each
In Stock
Get 1 by Wed, Dec 2 - Mon, Dec 7
In Stock
Get 1 by Wed, Dec 2 - Mon, Dec 7
Compare
Product Image of D2CG072N09958A Parts - Packaged Unit/RTUnot-to-sell-product
D2CG072N09958A Parts - Packaged Unit/RTU
SKU: D2CG072N09958A
York
SKU: D2CG072N09958A
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of D2CG180N32058A Parts - Packaged Unit/RTUnot-to-sell-product
D2CG180N32058A Parts - Packaged Unit/RTU
SKU: D2CG180N32058A
York
SKU: D2CG180N32058A
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DBG0603BL00001SAA Parts - Daikin Light Commercial Packaged Gas/Electric, Single Stagenot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DBG0603DH00001SAA Parts - Daikin Light Commercial Packaged Gas/Electric 14 SEER, Single Stagenot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DBG0607BH00001SAA Parts - Daikin Light Commercial Packaged Gas/Electric, Single Stagenot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DBG0364BM00001SAA Parts - Daikin Light Commercial Packaged Gas/Electric 14 SEER, Single Stagenot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DBG0483CL00001F Parts - Daikin DBG Series Gas/Electric Packaged Rooftop Unit (RTU)not-to-sell-product
Out of Stock
Get it by Thu, Dec 10 - Thu, Dec 17
Out of Stock
Get it by Thu, Dec 10 - Thu, Dec 17
Compare
Product Image of Diagonal Cutting Pliers, Insulated, High Leverage, 8", D228-8-INS
$63.00 each
In Stock
Get 7 by Mon, Nov 30 - Tue, Dec 1
In Stock
Get 7 by Mon, Nov 30 - Tue, Dec 1
Compare
Product Image of D2EE150A46 Parts - Packaged Unit/RTUnot-to-sell-product
D2EE150A46 Parts - Packaged Unit/RTU
SKU: D2EE150A46
York
SKU: D2EE150A46
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of D2EG150N16558 Parts - Packaged Unit/RTUnot-to-sell-product
D2EG150N16558 Parts - Packaged Unit/RTU
SKU: D2EG150N16558
York
SKU: D2EG150N16558
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DC11 3-Phase ODP General Purpose Motor, 286TS Frame (200V, 30 HP, 1780 RPM), D30P2HS
$2,938.81 each
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DD90 3-Phase ODP General Purpose Motor, 326T Frame (575V, 30 HP, 1185 RPM), D30P3G
$4,003.52 each
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of JK24 3-Phase ODP General Purpose Motor, 326T Frame (230V, 30 HP, 1185 RPM), D30V3B
$4,656.46 each
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DBG0484CL00001FAA Parts - Daikin Light Commercial Packaged Gas/Electric, Single Stagenot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of DBG0603B100001FAA Parts - Daikin Light Commercial Packaged Gas/Electric, Single Stagenot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of D2491100S Parts - Boilernot-to-sell-product
D2491100S Parts - Boiler
SKU: D2491100S
Utica-Dunkirk
SKU: D2491100S
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of D2491500S Parts - Boilernot-to-sell-product
D2491500S Parts - Boiler
SKU: D2491500S
Utica-Dunkirk
SKU: D2491500S
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of Casing Ci 2x1.5 La-f 125#
Casing Ci 2x1.5 La-f 125#
SKU: D250924-011
Armstrong Pumps
SKU: D250924-011
$2,254.03 each
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of Stfg Box Extention Bronze M
Stfg Box Extention Bronze M
SKU: D251813-041
Armstrong Pumps
SKU: D251813-041
$376.83 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of Brg Cover - I/b
Brg Cover - I/b
SKU: D251818-011
Armstrong Pumps
SKU: D251818-011
$269.88 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of HZ74 3-Phase ODP General Purpose Motor, 405T Frame (575V, 125 HP, 1785 RPM), D125P2G
$10,229.40 each
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of D1EB036A46A Parts - Packaged Unit/RTUnot-to-sell-product
D1EB036A46A Parts - Packaged Unit/RTU
SKU: D1EB036A46A
York
SKU: D1EB036A46A
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Resources
FAQs, Manuals & Videos
Articles
More About Wilo Z-15 Pump Parts

Wilo Z-15 pump parts are the replacement components contractors use to service and rebuild Z-15 wet-rotor circulator pumps found in residential and light commercial hydronic heating and hot water recirculation systems. The Z-15 is a single-speed, in-line circulator, and its most commonly replaced parts are the pump head, rotor and impeller assembly, and the mounting gaskets that seal the pump body to the piping flanges. Over years of continuous operation, mineral buildup and worn bearings inside the wet-rotor cartridge are the usual reasons a Z-15 needs a rebuild rather than a full replacement. Keeping gaskets, cartridges, and mounting hardware on hand lets a contractor return a system to service the same day instead of waiting on a full pump swap, which matters most on boiler systems where extended downtime affects a building's heat.

Subcategories

  • Pump Heads: Pump heads house the motor and electrical connections for the Z-15 circulator and bolt directly onto the wet-rotor cartridge below. Contractors replace a pump head when the motor windings fail or a bad capacitor stops the rotor from starting, rather than swapping the entire unit. Because the head separates from the wet end without draining the whole system in most installations, it's often the fastest single-part repair on a Z-15. Matching the voltage and speed rating to the original nameplate keeps the replacement head compatible with the existing wiring.
  • Rotor & Impeller Assemblies: The rotor and impeller assembly is the wet-rotor cartridge that spins inside the pump body to move water through the system. Mineral scale and sediment are the most common causes of a sluggish or seized rotor, especially in older cast iron hydronic loops. Replacing the assembly restores full flow without needing to replace the pump housing or motor head. A worn sleeve bearing inside the assembly is usually what causes the humming or grinding noise contractors hear before a Z-15 fails outright.
  • Mounting Gaskets & Flanges: Mounting gaskets seal the pump body against the flanges that connect it to the supply and return piping. A worn or improperly seated gasket is one of the most common sources of a slow weep leak at the pump union. Flanges themselves rarely need replacement unless they've been damaged during a prior installation or corroded from years of exposure to boiler water. Keeping the correct gasket size on hand avoids a return trip when a routine pump service uncovers a leak at the union.
  • Cartridge Seal Kits: Cartridge seal kits bundle the O-rings and shaft seals needed to reseal the wet-rotor cartridge after it's opened for cleaning or bearing replacement. Using a complete kit instead of individual seals reduces the chance of missing a small O-ring that causes a repeat callback. Seal kits are typically sized to the specific cartridge generation, so matching the kit to the pump's production era matters more than matching it to the overall Z-15 model name alone. A fresh seal kit is standard practice any time the cartridge is removed for service, even if the old seals look intact.
  • Buying Guide

    When sourcing Wilo Z-15 pump parts, start with the failure symptom rather than guessing at a full parts list. A pump that hums but doesn't spin usually points to a seized rotor or worn bearing, calling for a rotor and impeller assembly rather than a new pump head. A pump that won't start electrically, or trips a breaker, more often points to the motor windings or capacitor inside the pump head itself. Confirm the exact age and cartridge generation of the installed unit before ordering, since Wilo has updated the internal cartridge design over the years and parts from a newer cartridge don't always fit an older pump body. For jobs where the pump has been in continuous service for many years, rebuilding with a full cartridge seal kit alongside the rotor assembly is often more efficient than replacing components piecemeal, since it addresses wear across the whole wet end in one visit. Keep a small stock of the most commonly needed Wilo Z-15 pump parts, gaskets, seal kits, and a spare pump head, on hand for routine hydronic service calls, since these are the components most likely to fail from years of continuous operation. For a pump that's failed catastrophically or is several rebuilds in already, replacing the entire unit is often the more practical long-term choice over continuing to source individual parts.

    Frequently Asked Questions

    How do I know if my Wilo Z-15 needs a new pump head or a full rotor assembly?

    If the pump is silent and doesn't spin at all, check the motor head first, since that usually points to a failed capacitor or burned winding. If the pump hums or vibrates but the rotor won't turn, the wet-rotor cartridge itself is more likely the problem. Testing continuity at the motor terminals before ordering parts helps confirm which component actually failed.

    Can I rebuild a Z-15 without draining the whole heating system?

    In most installations, the pump head separates from the wet-rotor cartridge without opening the main piping, so a motor swap doesn't require draining the loop. Replacing the cartridge, gaskets, or flanges does require isolating and draining the pump section, though the rest of the system can often stay filled if isolation valves are present. Always confirm the specific installation has isolation valves before promising a no-drain repair.

    Why does my Z-15 keep leaking at the union even after a new gasket?

    A repeat leak after a gasket replacement is usually a sign the flange itself is corroded, warped, or wasn't torqued evenly during installation. Overtightening a new gasket can also distort it and cause the same leak to return. Checking the flange surface for pitting and torquing bolts in a cross pattern typically resolves a recurring union leak.

    How long does a Z-15 cartridge seal kit typically last?

    Seal life depends heavily on water quality and how often the system cycles, so there's no single fixed interval for every installation. Systems with harder water or more mineral content tend to wear seals faster than closed loops with treated water. Replacing the seal kit any time the cartridge is opened for service, rather than waiting for a visible leak, helps avoid a repeat callback.

    Is it worth rebuilding an older Z-15 or should I replace the whole pump?

    A rebuild makes sense when the pump body and flanges are still in good condition and only the wet-rotor cartridge or motor head has failed. Once a pump has needed several rebuilds over a short period, or the housing itself shows corrosion, replacing the entire unit is usually the more practical option. Weighing the age of the installation against the parts already on hand helps make that call quickly during a service visit.