Apply to be a TradeMaster!
Filter menu expanded

Filters

462,995 items
Reset

SORT

Wilo Z-15 Pump Parts

Help Face
Need a little help?
462995 items
Grid
List
Compare
Product Image of DSZC160241AA Parts - Goodman DSZC Series Heat Pump - 2 Ton - 16 SEER - Single Phasenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DSZC160241AD Parts - Goodman DSZC Series Heat Pump - 2 Ton - 16 SEER - Single Phasenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DSZC160241AE Parts - Goodman DSZC Series Heat Pump - 2 Ton - 16 SEER - Single Phasenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DRC1207WHGRAA Parts - Daikin Light Commercial Packaged Air Conditioner, Single Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DRC1504DHGRAA Parts - Daikin Light Commercial Packaged Air Conditioner, Single Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DRC1507LHGR Parts - Daikin Light Commercial Packaged Air Conditionernot-to-sell-product
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of DRC1507WHGR Parts - Daikin Light Commercial Packaged Air Conditionernot-to-sell-product
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of Colortouch Res Dehum Wifi4h/2c, DT4273
$386.66 each
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of DT4BD-042K Parts - Nordyne Heat Pumpnot-to-sell-product
DT4BD-042K Parts - Nordyne Heat Pump
SKU: DT4BD-042K
Nordyne
SKU: DT4BD-042K
Brand: Nordyne
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DT4BE-042K Parts - Nordyne Heat Pumpnot-to-sell-product
DT4BE-042K Parts - Nordyne Heat Pump
SKU: DT4BE-042K
Nordyne
SKU: DT4BE-042K
Brand: Nordyne
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DT4BX-036E Parts - Nordyne Heat Pumpnot-to-sell-product
DT4BX-036E Parts - Nordyne Heat Pump
SKU: DT4BX-036E
Nordyne
SKU: DT4BX-036E
Brand: Nordyne
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DP3GM4808041AA Parts - Daikin Packaged Gas/Electric/Dual 13.4 SEER2, Single Stage, Downflow/Horizontalnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DP3GM6108041AA Parts - Daikin Packaged Gas/Electric/Dual 13.4 SEER2, Single Stage, Downflow/Horizontalnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DRCS036B Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DRCS048B/A Parts - Central Air Conditionernot-to-sell-product
DRCS048B/A Parts - Central Air Conditioner
SKU: DRCS048B/A
Coleman
SKU: DRCS048B/A
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DRCS0601BE Parts - Coleman Air Conditionernot-to-sell-product
DRCS0601BE Parts - Coleman Air Conditioner
SKU: DRCS0601BE
Coleman
SKU: DRCS0601BE
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DRCS060B Parts - Coleman Air Conditionernot-to-sell-product
DRCS060B Parts - Coleman Air Conditioner
SKU: DRCS060B
Coleman
SKU: DRCS060B
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DT4BX-060G Parts - Nordyne Heat Pumpnot-to-sell-product
DT4BX-060G Parts - Nordyne Heat Pump
SKU: DT4BX-060G
Nordyne
SKU: DT4BX-060G
Brand: Nordyne
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DT5BD-030K Parts - Nordyne Heat Pumpnot-to-sell-product
DT5BD-030K Parts - Nordyne Heat Pump
SKU: DT5BD-030K
Nordyne
SKU: DT5BD-030K
Brand: Nordyne
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DT5QD-030KA Parts - Nordyne Heat Pumpnot-to-sell-product
DT5QD-030KA Parts - Nordyne Heat Pump
SKU: DT5QD-030KA
Nordyne
SKU: DT5QD-030KA
Brand: Nordyne
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DT5QD-042K Parts - Nordyne Heat Pumpnot-to-sell-product
DT5QD-042K Parts - Nordyne Heat Pump
SKU: DT5QD-042K
Nordyne
SKU: DT5QD-042K
Brand: Nordyne
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DT3BD-030K Parts - Nordyne Heat Pumpnot-to-sell-product
DT3BD-030K Parts - Nordyne Heat Pump
SKU: DT3BD-030K
Nordyne
SKU: DT3BD-030K
Brand: Nordyne
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DT5BD-024KT Parts - Nordyne Heat Pumpnot-to-sell-product
DT5BD-024KT Parts - Nordyne Heat Pump
SKU: DT5BD-024KT
Nordyne
SKU: DT5BD-024KT
Brand: Nordyne
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DP3HH2441AA Parts - Daikin Packaged Heat Pump, Horizontalnot-to-sell-product
VIEW REPLACEMENT PARTS
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DRE-120, 120 Gallon 45 KW Lime Tamer Commercial Electric Water Heater
Phone Icon
CALL TO ORDER
1-888-757-4774
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DRG0361D100001FBA Parts - Daikin Light Commercial Packaged Gas/Electric, Two Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DTC060XXX1DXDX Parts - Daikin Light Commercial Packaged Air Conditionernot-to-sell-product
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of DTCQ0241BAG Parts - Central Air Conditionernot-to-sell-product
DTCQ0241BAG Parts - Central Air Conditioner
SKU: DTCQ0241BAG
Coleman
SKU: DTCQ0241BAG
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DTCQ0361BA Parts - York Central Air Conditionernot-to-sell-product
DTCQ0361BA Parts - York Central Air Conditioner
SKU: DTCQ0361BA
York
SKU: DTCQ0361BA
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of 6" x 1,000' Caution Buried Electric Line Below Detectable Underground Tape, DT6 RE
$234.11 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of DTCQ0481BA Parts - York Central Air Conditionernot-to-sell-product
DTCQ0481BA Parts - York Central Air Conditioner
SKU: DTCQ0481BA
York
SKU: DTCQ0481BA
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of 3 Pole Easy TeSys DPE IEC Non-Reversing Contactor (15HP, 32A, 480 VAC, 24V)
$50.58 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 3 Pole Easy TeSys DPE IEC No-Reversing Contactor (20HP, 38A, 480 VAC, 24V)
$50.58 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of DRG0361DL00001SBA Parts - Daikin Light Commercial Packaged Gas/Electric, Two Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DRG0363DHGRAA Parts - Daikin Light Commercial Packaged Gas/Electric, Two Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DRG0364D800001F Parts - Daikin Light Commercial Packaged Gas/Electricnot-to-sell-product
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of DRG0364D800001FAA Parts - Daikin Light Commercial Packaged Gas/Electric, Two Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DRG0364WHGR Parts - Daikin Light Commercial Packaged Gas/Electricnot-to-sell-product
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of DRG0367DM00001SAA Parts - Daikin Light Commercial Packaged Gas/Electric, Two Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DTG0480903DVXM Parts - Daikin Light Commercial Packaged Gas/Electricnot-to-sell-product
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of Gasket - Intake Air Filter Sides, DTGL012
$1.84 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of DTH048XXX3DXXXAA Parts - Daikin Light Commercial Packaged Heat Pump 15 SEER, Single Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Gas fitting 3/4NPT SET DTJ, DTJE725
Gas fitting 3/4NPT SET DTJ, DTJE725
SKU: DTJE725
Noritz
SKU: DTJE725
Brand: Noritz
$46.16 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of DTG0360453DXXXAA Parts - Daikin Light Commercial Packaged Gas/Electric 15 SEER, Single Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DTG0360901DVDX Parts - Daikin Light Commercial Packaged Gas/Electricnot-to-sell-product
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of DTG0481151DXXX Parts - DTG Series Commercial Gas Pack - 4 Ton - 1150K BTU - Direct Drivenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DTG0600903DHKC Parts - Daikin Light Commercial Packaged Gas/Electricnot-to-sell-product
DTG0600903DHKC Parts - Daikin Light Commercial Packaged Gas/Electric
SKU: DTG0600903DHKC
Daikin
SKU: DTG0600903DHKC
Brand: Daikin
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of Easy TeSys DPER Thermal Overload Relay (0.40 - 0.63A, Class 10)
$26.06 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Resources
FAQs, Manuals & Videos
Articles
More About Wilo Z-15 Pump Parts

Wilo Z-15 pump parts are the replacement components contractors use to service and rebuild Z-15 wet-rotor circulator pumps found in residential and light commercial hydronic heating and hot water recirculation systems. The Z-15 is a single-speed, in-line circulator, and its most commonly replaced parts are the pump head, rotor and impeller assembly, and the mounting gaskets that seal the pump body to the piping flanges. Over years of continuous operation, mineral buildup and worn bearings inside the wet-rotor cartridge are the usual reasons a Z-15 needs a rebuild rather than a full replacement. Keeping gaskets, cartridges, and mounting hardware on hand lets a contractor return a system to service the same day instead of waiting on a full pump swap, which matters most on boiler systems where extended downtime affects a building's heat.

Subcategories

  • Pump Heads: Pump heads house the motor and electrical connections for the Z-15 circulator and bolt directly onto the wet-rotor cartridge below. Contractors replace a pump head when the motor windings fail or a bad capacitor stops the rotor from starting, rather than swapping the entire unit. Because the head separates from the wet end without draining the whole system in most installations, it's often the fastest single-part repair on a Z-15. Matching the voltage and speed rating to the original nameplate keeps the replacement head compatible with the existing wiring.
  • Rotor & Impeller Assemblies: The rotor and impeller assembly is the wet-rotor cartridge that spins inside the pump body to move water through the system. Mineral scale and sediment are the most common causes of a sluggish or seized rotor, especially in older cast iron hydronic loops. Replacing the assembly restores full flow without needing to replace the pump housing or motor head. A worn sleeve bearing inside the assembly is usually what causes the humming or grinding noise contractors hear before a Z-15 fails outright.
  • Mounting Gaskets & Flanges: Mounting gaskets seal the pump body against the flanges that connect it to the supply and return piping. A worn or improperly seated gasket is one of the most common sources of a slow weep leak at the pump union. Flanges themselves rarely need replacement unless they've been damaged during a prior installation or corroded from years of exposure to boiler water. Keeping the correct gasket size on hand avoids a return trip when a routine pump service uncovers a leak at the union.
  • Cartridge Seal Kits: Cartridge seal kits bundle the O-rings and shaft seals needed to reseal the wet-rotor cartridge after it's opened for cleaning or bearing replacement. Using a complete kit instead of individual seals reduces the chance of missing a small O-ring that causes a repeat callback. Seal kits are typically sized to the specific cartridge generation, so matching the kit to the pump's production era matters more than matching it to the overall Z-15 model name alone. A fresh seal kit is standard practice any time the cartridge is removed for service, even if the old seals look intact.
  • Buying Guide

    When sourcing Wilo Z-15 pump parts, start with the failure symptom rather than guessing at a full parts list. A pump that hums but doesn't spin usually points to a seized rotor or worn bearing, calling for a rotor and impeller assembly rather than a new pump head. A pump that won't start electrically, or trips a breaker, more often points to the motor windings or capacitor inside the pump head itself. Confirm the exact age and cartridge generation of the installed unit before ordering, since Wilo has updated the internal cartridge design over the years and parts from a newer cartridge don't always fit an older pump body. For jobs where the pump has been in continuous service for many years, rebuilding with a full cartridge seal kit alongside the rotor assembly is often more efficient than replacing components piecemeal, since it addresses wear across the whole wet end in one visit. Keep a small stock of the most commonly needed Wilo Z-15 pump parts, gaskets, seal kits, and a spare pump head, on hand for routine hydronic service calls, since these are the components most likely to fail from years of continuous operation. For a pump that's failed catastrophically or is several rebuilds in already, replacing the entire unit is often the more practical long-term choice over continuing to source individual parts.

    Frequently Asked Questions

    How do I know if my Wilo Z-15 needs a new pump head or a full rotor assembly?

    If the pump is silent and doesn't spin at all, check the motor head first, since that usually points to a failed capacitor or burned winding. If the pump hums or vibrates but the rotor won't turn, the wet-rotor cartridge itself is more likely the problem. Testing continuity at the motor terminals before ordering parts helps confirm which component actually failed.

    Can I rebuild a Z-15 without draining the whole heating system?

    In most installations, the pump head separates from the wet-rotor cartridge without opening the main piping, so a motor swap doesn't require draining the loop. Replacing the cartridge, gaskets, or flanges does require isolating and draining the pump section, though the rest of the system can often stay filled if isolation valves are present. Always confirm the specific installation has isolation valves before promising a no-drain repair.

    Why does my Z-15 keep leaking at the union even after a new gasket?

    A repeat leak after a gasket replacement is usually a sign the flange itself is corroded, warped, or wasn't torqued evenly during installation. Overtightening a new gasket can also distort it and cause the same leak to return. Checking the flange surface for pitting and torquing bolts in a cross pattern typically resolves a recurring union leak.

    How long does a Z-15 cartridge seal kit typically last?

    Seal life depends heavily on water quality and how often the system cycles, so there's no single fixed interval for every installation. Systems with harder water or more mineral content tend to wear seals faster than closed loops with treated water. Replacing the seal kit any time the cartridge is opened for service, rather than waiting for a visible leak, helps avoid a repeat callback.

    Is it worth rebuilding an older Z-15 or should I replace the whole pump?

    A rebuild makes sense when the pump body and flanges are still in good condition and only the wet-rotor cartridge or motor head has failed. Once a pump has needed several rebuilds over a short period, or the housing itself shows corrosion, replacing the entire unit is usually the more practical option. Weighing the age of the installation against the parts already on hand helps make that call quickly during a service visit.