Apply to be a TradeMaster!
Filter menu expanded

Filters

462,995 items
Reset

SORT

Wilo Z-15 Pump Parts

Help Face
Need a little help?
462995 items
Grid
List
Compare
Product Image of E12Q3-20-1 Parts - Lennox Furnacenot-to-sell-product
E12Q3-20-1 Parts - Lennox Furnace
SKU: E12Q3-20-1
Lennox
SKU: E12Q3-20-1
Brand: Lennox
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Transformer Reactor, EBJ36274402
Transformer Reactor, EBJ36274402
SKU: EBJ36274402
LG
SKU: EBJ36274402
Brand: LG
$82.39 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Transformer, Reactor, EBJ62950506
Transformer, Reactor, EBJ62950506
SKU: EBJ62950506
LG
SKU: EBJ62950506
Brand: LG
$177.99 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 3/4" LL Body, EMT Aluminum Conduit Body, EBLL-2
$20.90 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of ebm-papst 12" ECM Unit Cooler Fan Assembly w/ Fixed RPM
$239.57 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of PCB Assembly, EBR36932815
PCB Assembly, EBR36932815
SKU: EBR36932815
LG
SKU: EBR36932815
Brand: LG
$1,747.41 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Sub PCB Assembly, EBR36985215
Sub PCB Assembly, EBR36985215
SKU: EBR36985215
LG
SKU: EBR36985215
Brand: LG
$6.49 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of PCB Assembly, Sub, EBR80149104
PCB Assembly, Sub, EBR80149104
SKU: EBR80149104
LG
SKU: EBR80149104
Brand: LG
$6.99 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of PCB Assembly, Sub, EBR80149106
PCB Assembly, Sub, EBR80149106
SKU: EBR80149106
LG
SKU: EBR80149106
Brand: LG
$8.22 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of PCB Assembly, Sub, EBR80153103
PCB Assembly, Sub, EBR80153103
SKU: EBR80153103
LG
SKU: EBR80153103
Brand: LG
$8.99 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of PCB Assembly, Sub, EBR80362403
PCB Assembly, Sub, EBR80362403
SKU: EBR80362403
LG
SKU: EBR80362403
Brand: LG
$4.99 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of E15 Series Time-Initiated Heat Pump De-Ice Control w/ 60" Capillary
$208.92 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 2.30" wc SPDT Air Pressure Switch, E2312400
2.30" wc SPDT Air Pressure Switch, E2312400
SKU: E2312400
Laars
SKU: E2312400
Brand: Laars
$42.13 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Box, Electrical, Squareuare, 4 X 1.5 In, E2341200
$7.82 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of PCB Assembly, Main, EBR39904823
PCB Assembly, Main, EBR39904823
SKU: EBR39904823
LG
SKU: EBR39904823
Brand: LG
$107.99 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Option PCB Assembly, EBR57215502
Option PCB Assembly, EBR57215502
SKU: EBR57215502
LG
SKU: EBR57215502
Brand: LG
$7.50 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of PCB Assembly, Sub, EBR58014117
PCB Assembly, Sub, EBR58014117
SKU: EBR58014117
LG
SKU: EBR58014117
Brand: LG
$8.99 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of PCB Assembly, Sub, EBR61161614
PCB Assembly, Sub, EBR61161614
SKU: EBR61161614
LG
SKU: EBR61161614
Brand: LG
$8.99 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of PCB Assembly, Fan, EBR74364901
PCB Assembly, Fan, EBR74364901
SKU: EBR74364901
LG
SKU: EBR74364901
Brand: LG
$649.66 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of PCB Assembly, EBR83796824
PCB Assembly, EBR83796824
SKU: EBR83796824
LG
SKU: EBR83796824
Brand: LG
$493.80 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of E1FB090A50B Parts - York Heat Pumpnot-to-sell-product
E1FB090A50B Parts - York Heat Pump
SKU: E1FB090A50B
York
SKU: E1FB090A50B
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of E1FB120A25 Parts - York Heat Pumpnot-to-sell-product
E1FB120A25 Parts - York Heat Pump
SKU: E1FB120A25
York
SKU: E1FB120A25
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Relay, Pump (spst), E2367900
Relay, Pump (spst), E2367900
SKU: E2367900
Laars
SKU: E2367900
Brand: Laars
$62.55 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of SolaHD 1 Phase, 1/4 kVA, Control Transformer, E250
SolaHD 1 Phase, 1/4 kVA, Control Transformer, E250
SKU: E250-EMERSON
Emerson
SKU: E250-EMERSON
Brand: Emerson
$320.55 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of PCB Assembly, Option, EBR76398720
PCB Assembly, Option, EBR76398720
SKU: EBR76398720
LG
SKU: EBR76398720
Brand: LG
$5.49 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of EC-03 Parts - Boilernot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of GPG1430040M41BB Parts - Goodman GPG14M Downflow/Horizontal Packaged Gas/Electric/Dual 14 SEER, 1 Stage Cooling, 1 Speed EEM, 2.5 Tonnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of GPG1430060M41BA Parts - Goodman GPG Series Gas Pack - 2-1/2 Ton - 14 SEER - 60K BTUnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of GPG1436040M41AB Parts - Goodman GPG Series Gas Pack - 3 Ton - 14 SEER - 40K BTUnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of GPG1436060M41AB Parts - Goodman GPG14M Downflow/Horizontal Packaged Gas/Electric/Dual 14 SEER, 1 Stage Cooling, 1 Speed EEM, 3 Tonnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of GPG1436080M41CA Parts - Goodman GPG14M Downflow/Horizontal Packaged Gas/Electric/Dual 14 SEER, 1 Stage Cooling, 1 Speed EEM, 3 Tonnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of GPG1442080M41CA Parts - Goodman GPG14M Downflow/Horizontal Packaged Gas/Electric/Dual 14 SEER, 1 Stage Cooling, 1 Speed EEM, 3.5 Tonnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of GPG1448060M41AB Parts - Goodman GPG Series Gas Pack - 4 Ton - 14 SEER - 60K BTUnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of GSZ130181AC Parts - Goodman GSZ Series Heat Pump - 1-1/2 Ton - 13 SEER - 1 Phasenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of GSZ130241BB Parts - Goodman GSZ Series Heat Pump - 2 Ton - 13 SEER - 1 Phasenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of GSZ130251BA Parts - Goodman Split System Heat Pump - 2 Ton - 13 SEERnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of GSZH504810AA Parts - Goodman GSZH5 Split Heat Pump 15.2 SEER2 & HSPF, 1 Stage, 4 Tonnot-to-sell-product
GSZH504810AA Parts - Goodman GSZH5 Split Heat Pump 15.2 SEER2 & HSPF, 1 Stage, 4 Ton
SKU: GSZH504810AA
Goodman
SKU: GSZH504810AA
Brand: Goodman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of GSZS604810AB Parts - Goodman Heat Pumpnot-to-sell-product
GSZS604810AB Parts - Goodman Heat Pump
SKU: GSZS604810AB
Goodman
SKU: GSZS604810AB
Brand: Goodman
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of GPG1460120M4EAA Parts - Goodman GPG Series Gas Packnot-to-sell-product
GPG1460120M4EAA Parts - Goodman GPG Series Gas Pack
SKU: GPG1460120M4EAA
Goodman
SKU: GPG1460120M4EAA
Brand: Goodman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of GPG153709041AC Parts - Goodman GPG Series Gas Pack - 3 Ton - 14-1/2 SEER - 80% AFUE - Multi Positionnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of GR4GC-024K072C Parts - Nordyne Packaged Unit/RTUnot-to-sell-product
GR4GC-024K072C Parts - Nordyne Packaged Unit/RTU
SKU: GR4GC-024K072C
Nordyne
SKU: GR4GC-024K072C
Brand: Nordyne
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of GSZ130371AD Parts - Goodman GSZ Series Heat Pump - 3 Ton - 13 SEER - Single Phasenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of GSZ130484AC Parts - Goodman Split System Heat Pump - 4 Ton - 13 SEERnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of GSZ140181KC Parts - Goodman GSZ Series Heat Pump - 1-1/2 Ton - 14 SEER - 208/230Vnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of GSZ140181KE Parts - Goodman GSZ Series Heat Pump - 1-1/2 Ton - 14 SEER - 208/230Vnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of GSZ140191AC Parts - Goodman GSZ Series Heat Pump - 1-1/2 Ton - 14 SEER - 17K BTU -208/230Vnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Drawer Rail, GT011135-R
Drawer Rail, GT011135-R
SKU: GT011135-R
Turbo Air
SKU: GT011135-R
Brand: Turbo Air
$144.20 each
In Stock
Get 10 by Wed, Nov 25
In Stock
Get 10 by Wed, Nov 25
Compare
Product Image of GT072VTLNDET1XX1 Parts -6 Ton Geothermal Heat Pump Packaged Unit Vertical Top Left Cupronickel w/Desuperheater (208/230-1-60)not-to-sell-product
GT072VTLNDET1XX1 Parts -6 Ton Geothermal Heat Pump Packaged Unit Vertical Top Left Cupronickel w/Desuperheater (208/230-1-60)
SKU: GT072VTLNDET1XX1
Carrier
SKU: GT072VTLNDET1XX1
Brand: Carrier
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Resources
FAQs, Manuals & Videos
Articles
More About Wilo Z-15 Pump Parts

Wilo Z-15 pump parts are the replacement components contractors use to service and rebuild Z-15 wet-rotor circulator pumps found in residential and light commercial hydronic heating and hot water recirculation systems. The Z-15 is a single-speed, in-line circulator, and its most commonly replaced parts are the pump head, rotor and impeller assembly, and the mounting gaskets that seal the pump body to the piping flanges. Over years of continuous operation, mineral buildup and worn bearings inside the wet-rotor cartridge are the usual reasons a Z-15 needs a rebuild rather than a full replacement. Keeping gaskets, cartridges, and mounting hardware on hand lets a contractor return a system to service the same day instead of waiting on a full pump swap, which matters most on boiler systems where extended downtime affects a building's heat.

Subcategories

  • Pump Heads: Pump heads house the motor and electrical connections for the Z-15 circulator and bolt directly onto the wet-rotor cartridge below. Contractors replace a pump head when the motor windings fail or a bad capacitor stops the rotor from starting, rather than swapping the entire unit. Because the head separates from the wet end without draining the whole system in most installations, it's often the fastest single-part repair on a Z-15. Matching the voltage and speed rating to the original nameplate keeps the replacement head compatible with the existing wiring.
  • Rotor & Impeller Assemblies: The rotor and impeller assembly is the wet-rotor cartridge that spins inside the pump body to move water through the system. Mineral scale and sediment are the most common causes of a sluggish or seized rotor, especially in older cast iron hydronic loops. Replacing the assembly restores full flow without needing to replace the pump housing or motor head. A worn sleeve bearing inside the assembly is usually what causes the humming or grinding noise contractors hear before a Z-15 fails outright.
  • Mounting Gaskets & Flanges: Mounting gaskets seal the pump body against the flanges that connect it to the supply and return piping. A worn or improperly seated gasket is one of the most common sources of a slow weep leak at the pump union. Flanges themselves rarely need replacement unless they've been damaged during a prior installation or corroded from years of exposure to boiler water. Keeping the correct gasket size on hand avoids a return trip when a routine pump service uncovers a leak at the union.
  • Cartridge Seal Kits: Cartridge seal kits bundle the O-rings and shaft seals needed to reseal the wet-rotor cartridge after it's opened for cleaning or bearing replacement. Using a complete kit instead of individual seals reduces the chance of missing a small O-ring that causes a repeat callback. Seal kits are typically sized to the specific cartridge generation, so matching the kit to the pump's production era matters more than matching it to the overall Z-15 model name alone. A fresh seal kit is standard practice any time the cartridge is removed for service, even if the old seals look intact.
  • Buying Guide

    When sourcing Wilo Z-15 pump parts, start with the failure symptom rather than guessing at a full parts list. A pump that hums but doesn't spin usually points to a seized rotor or worn bearing, calling for a rotor and impeller assembly rather than a new pump head. A pump that won't start electrically, or trips a breaker, more often points to the motor windings or capacitor inside the pump head itself. Confirm the exact age and cartridge generation of the installed unit before ordering, since Wilo has updated the internal cartridge design over the years and parts from a newer cartridge don't always fit an older pump body. For jobs where the pump has been in continuous service for many years, rebuilding with a full cartridge seal kit alongside the rotor assembly is often more efficient than replacing components piecemeal, since it addresses wear across the whole wet end in one visit. Keep a small stock of the most commonly needed Wilo Z-15 pump parts, gaskets, seal kits, and a spare pump head, on hand for routine hydronic service calls, since these are the components most likely to fail from years of continuous operation. For a pump that's failed catastrophically or is several rebuilds in already, replacing the entire unit is often the more practical long-term choice over continuing to source individual parts.

    Frequently Asked Questions

    How do I know if my Wilo Z-15 needs a new pump head or a full rotor assembly?

    If the pump is silent and doesn't spin at all, check the motor head first, since that usually points to a failed capacitor or burned winding. If the pump hums or vibrates but the rotor won't turn, the wet-rotor cartridge itself is more likely the problem. Testing continuity at the motor terminals before ordering parts helps confirm which component actually failed.

    Can I rebuild a Z-15 without draining the whole heating system?

    In most installations, the pump head separates from the wet-rotor cartridge without opening the main piping, so a motor swap doesn't require draining the loop. Replacing the cartridge, gaskets, or flanges does require isolating and draining the pump section, though the rest of the system can often stay filled if isolation valves are present. Always confirm the specific installation has isolation valves before promising a no-drain repair.

    Why does my Z-15 keep leaking at the union even after a new gasket?

    A repeat leak after a gasket replacement is usually a sign the flange itself is corroded, warped, or wasn't torqued evenly during installation. Overtightening a new gasket can also distort it and cause the same leak to return. Checking the flange surface for pitting and torquing bolts in a cross pattern typically resolves a recurring union leak.

    How long does a Z-15 cartridge seal kit typically last?

    Seal life depends heavily on water quality and how often the system cycles, so there's no single fixed interval for every installation. Systems with harder water or more mineral content tend to wear seals faster than closed loops with treated water. Replacing the seal kit any time the cartridge is opened for service, rather than waiting for a visible leak, helps avoid a repeat callback.

    Is it worth rebuilding an older Z-15 or should I replace the whole pump?

    A rebuild makes sense when the pump body and flanges are still in good condition and only the wet-rotor cartridge or motor head has failed. Once a pump has needed several rebuilds over a short period, or the housing itself shows corrosion, replacing the entire unit is usually the more practical option. Weighing the age of the installation against the parts already on hand helps make that call quickly during a service visit.