Apply to be a TradeMaster!
Filter menu expanded

Filters

462,995 items
Reset

SORT

Wilo Z-15 Pump Parts

Help Face
Need a little help?
462995 items
Grid
List
Compare
Product Image of CH3024QKB1 Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CH3030QKB1 Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CH3060VHA2 Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CH3060VKA2 Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CGAA2506MB Parts - Trane Central Air Conditionernot-to-sell-product
CGAA2506MB Parts - Trane Central Air Conditioner
SKU: CGAA2506MB
Trane
SKU: CGAA2506MB
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CGAA4003RA Parts - Trane Central Air Conditionernot-to-sell-product
CGAA4003RA Parts - Trane Central Air Conditioner
SKU: CGAA4003RA
Trane
SKU: CGAA4003RA
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CGAA6001MB Parts - Trane Central Air Conditionernot-to-sell-product
CGAA6001MB Parts - Trane Central Air Conditioner
SKU: CGAA6001MB
Trane
SKU: CGAA6001MB
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CGH12520D Parts - Coleman Furnacenot-to-sell-product
CGH12520D Parts - Coleman Furnace
SKU: CGH12520D
Coleman
SKU: CGH12520D
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CGHBC752EB Parts - Trane Central Air Conditionernot-to-sell-product
CGHBC752EB Parts - Trane Central Air Conditioner
SKU: CGHBC752EB
Trane
SKU: CGHBC752EB
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CKLB36-1 Parts - Janitrol Air Conditionernot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CKQ30-1 Parts - Janitrol Air Conditionernot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CKTS48-1 Parts - Janitrol Air Conditionernot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CGRBC151MC Parts - Trane Central Air Conditionernot-to-sell-product
CGRBC151MC Parts - Trane Central Air Conditioner
SKU: CGRBC151MC
Trane
SKU: CGRBC151MC
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CGRBC203MA Parts - Trane Central Air Conditionernot-to-sell-product
CGRBC203MA Parts - Trane Central Air Conditioner
SKU: CGRBC203MA
Trane
SKU: CGRBC203MA
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CGS40C-P Parts - Boilernot-to-sell-product
CGS40C-P Parts - Boiler
SKU: CGS40C-P
New Yorker
SKU: CGS40C-P
Brand: New Yorker
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CL2MLP Luminator High Visibility Breathable Mesh Safety Vest w/ Silver Reflective Stripes, Lime (Large)
$22.08 each
In Stock
Get 5 by Fri, Nov 27 - Mon, Nov 30
In Stock
Get 5 by Fri, Nov 27 - Mon, Nov 30
Compare
Product Image of CL3-091-WT Parts - Boilernot-to-sell-product
CL3-091-WT Parts - Boiler
SKU: CL3-091-WT
New Yorker
SKU: CL3-091-WT
Brand: New Yorker
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CL3-105-ST Parts - Boilernot-to-sell-product
CL3-105-ST Parts - Boiler
SKU: CL3-105-ST
New Yorker
SKU: CL3-105-ST
Brand: New Yorker
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CH5036VHA2 Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CH5042VKA2 Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CH5042VKB2 Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CH5042VKB5 Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CH5048QKA4 Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of 1/2" x 12" ChamFlex Hose Push-Fit x Push-Fit
1/2" x 12" ChamFlex Hose Push-Fit x Push-Fit
SKU: CH050012PP0000
Chamflex
SKU: CH050012PP0000
Brand: Chamflex
$30.17 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 1/2" x 36" ChamFlex Hose Push-Fit x Push-Fit
1/2" x 36" ChamFlex Hose Push-Fit x Push-Fit
SKU: CH050036PP0000
Chamflex
SKU: CH050036PP0000
Brand: Chamflex
$39.61 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 3/4" x 18" ChamFlex Hose Push-Fit x Push-Fit
3/4" x 18" ChamFlex Hose Push-Fit x Push-Fit
SKU: CH075018PP0000
Chamflex
SKU: CH075018PP0000
Brand: Chamflex
$44.13 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of CL4-210-ST Parts - Boilernot-to-sell-product
CL4-210-ST Parts - Boiler
SKU: CL4-210-ST
New Yorker
SKU: CL4-210-ST
Brand: New Yorker
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Replacement Boiler Non-Heater, 4 Section Cl Series Oil Boiler, CL4-WN
$2,266.96 each
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CL5-280-ST Parts - Boilernot-to-sell-product
CL5-280-ST Parts - Boiler
SKU: CL5-280-ST
New Yorker
SKU: CL5-280-ST
Brand: New Yorker
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CL60-3C Parts - Janitrol Air Conditionernot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CH5536VKC1 Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CH5536VKD1 Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CH5560VHC1 Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CH16NA018P0GAAAA Parts -Carrier 1.5 Ton 16 SEER Residential Heat Pump Condensing Unitnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CH30-1B Parts - Janitrol Air Conditionernot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CNPHP6124ALAEAAA Parts - Carrier Cased N-Coil Evaporator Coilnot-to-sell-product
CNPHP6124ALAEAAA Parts - Carrier Cased N-Coil Evaporator Coil
SKU: CNPHP6124ALAEAAA
Carrier
SKU: CNPHP6124ALAEAAA
Brand: Carrier
Backorder
Get it by Tue, Feb 23 - Tue, May 18
Backorder
Get it by Tue, Feb 23 - Tue, May 18
Compare
Product Image of CLJ18-1A Parts - Janitrol Air Conditionernot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CLJ36-1C Parts - Janitrol Air Conditionernot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CTA090A10AAA Parts - Trane Central Air Conditionernot-to-sell-product
CTA090A10AAA Parts - Trane Central Air Conditioner
SKU: CTA090A10AAA
Trane
SKU: CTA090A10AAA
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of CTA120A800AA Parts - Trane Central Air Conditionernot-to-sell-product
CTA120A800AA Parts - Trane Central Air Conditioner
SKU: CTA120A800AA
Trane
SKU: CTA120A800AA
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Skylark Contour LED+ Dimmer Switch, No 150W LED or 600W Inc/Hal, 120V, Single Pole/3-Way, Ivory
$24.49 each
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of Hvac Current Probe
Hvac Current Probe
SKU: CPH100
Supco
SKU: CPH100
Brand: Supco
$187.30 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of CPH120XXX4BXJXAA Parts - Goodman Commercial Packaged Heat Pumpnot-to-sell-product
CPH120XXX4BXJXAA Parts - Goodman Commercial Packaged Heat Pump
SKU: CPH120XXX4BXJXAA
Goodman
SKU: CPH120XXX4BXJXAA
Brand: Goodman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Skylark Contour LED+ Dimmer, 300W 1 Pole 3-way Dimmer Switch (Almond)
$71.24 each
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of Skylark Contour Quiet 3-Speed Fan Control, No 1.5A 3-Speed Ceiling Fan, 120V, 1 Pole/3-Way, Brown
$22.29 each
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of Heater 1000w 240v
Heater 1000w 240v
SKU: CPH804-240
Supco
SKU: CPH804-240
Brand: Supco
$63.22 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Comm Pan Heater 120v 1500w
Comm Pan Heater 120v 1500w
SKU: CPH819
Supco
SKU: CPH819
Brand: Supco
$99.85 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Terminal Board, CPHK50AA051
Terminal Board, CPHK50AA051
SKU: CPHK50AA051
Carrier
SKU: CPHK50AA051
Brand: Carrier
$190.55 each
In Stock
Get 1 by Wed, Nov 25
In Stock
Get 1 by Wed, Nov 25
Resources
FAQs, Manuals & Videos
Articles
More About Wilo Z-15 Pump Parts

Wilo Z-15 pump parts are the replacement components contractors use to service and rebuild Z-15 wet-rotor circulator pumps found in residential and light commercial hydronic heating and hot water recirculation systems. The Z-15 is a single-speed, in-line circulator, and its most commonly replaced parts are the pump head, rotor and impeller assembly, and the mounting gaskets that seal the pump body to the piping flanges. Over years of continuous operation, mineral buildup and worn bearings inside the wet-rotor cartridge are the usual reasons a Z-15 needs a rebuild rather than a full replacement. Keeping gaskets, cartridges, and mounting hardware on hand lets a contractor return a system to service the same day instead of waiting on a full pump swap, which matters most on boiler systems where extended downtime affects a building's heat.

Subcategories

  • Pump Heads: Pump heads house the motor and electrical connections for the Z-15 circulator and bolt directly onto the wet-rotor cartridge below. Contractors replace a pump head when the motor windings fail or a bad capacitor stops the rotor from starting, rather than swapping the entire unit. Because the head separates from the wet end without draining the whole system in most installations, it's often the fastest single-part repair on a Z-15. Matching the voltage and speed rating to the original nameplate keeps the replacement head compatible with the existing wiring.
  • Rotor & Impeller Assemblies: The rotor and impeller assembly is the wet-rotor cartridge that spins inside the pump body to move water through the system. Mineral scale and sediment are the most common causes of a sluggish or seized rotor, especially in older cast iron hydronic loops. Replacing the assembly restores full flow without needing to replace the pump housing or motor head. A worn sleeve bearing inside the assembly is usually what causes the humming or grinding noise contractors hear before a Z-15 fails outright.
  • Mounting Gaskets & Flanges: Mounting gaskets seal the pump body against the flanges that connect it to the supply and return piping. A worn or improperly seated gasket is one of the most common sources of a slow weep leak at the pump union. Flanges themselves rarely need replacement unless they've been damaged during a prior installation or corroded from years of exposure to boiler water. Keeping the correct gasket size on hand avoids a return trip when a routine pump service uncovers a leak at the union.
  • Cartridge Seal Kits: Cartridge seal kits bundle the O-rings and shaft seals needed to reseal the wet-rotor cartridge after it's opened for cleaning or bearing replacement. Using a complete kit instead of individual seals reduces the chance of missing a small O-ring that causes a repeat callback. Seal kits are typically sized to the specific cartridge generation, so matching the kit to the pump's production era matters more than matching it to the overall Z-15 model name alone. A fresh seal kit is standard practice any time the cartridge is removed for service, even if the old seals look intact.
  • Buying Guide

    When sourcing Wilo Z-15 pump parts, start with the failure symptom rather than guessing at a full parts list. A pump that hums but doesn't spin usually points to a seized rotor or worn bearing, calling for a rotor and impeller assembly rather than a new pump head. A pump that won't start electrically, or trips a breaker, more often points to the motor windings or capacitor inside the pump head itself. Confirm the exact age and cartridge generation of the installed unit before ordering, since Wilo has updated the internal cartridge design over the years and parts from a newer cartridge don't always fit an older pump body. For jobs where the pump has been in continuous service for many years, rebuilding with a full cartridge seal kit alongside the rotor assembly is often more efficient than replacing components piecemeal, since it addresses wear across the whole wet end in one visit. Keep a small stock of the most commonly needed Wilo Z-15 pump parts, gaskets, seal kits, and a spare pump head, on hand for routine hydronic service calls, since these are the components most likely to fail from years of continuous operation. For a pump that's failed catastrophically or is several rebuilds in already, replacing the entire unit is often the more practical long-term choice over continuing to source individual parts.

    Frequently Asked Questions

    How do I know if my Wilo Z-15 needs a new pump head or a full rotor assembly?

    If the pump is silent and doesn't spin at all, check the motor head first, since that usually points to a failed capacitor or burned winding. If the pump hums or vibrates but the rotor won't turn, the wet-rotor cartridge itself is more likely the problem. Testing continuity at the motor terminals before ordering parts helps confirm which component actually failed.

    Can I rebuild a Z-15 without draining the whole heating system?

    In most installations, the pump head separates from the wet-rotor cartridge without opening the main piping, so a motor swap doesn't require draining the loop. Replacing the cartridge, gaskets, or flanges does require isolating and draining the pump section, though the rest of the system can often stay filled if isolation valves are present. Always confirm the specific installation has isolation valves before promising a no-drain repair.

    Why does my Z-15 keep leaking at the union even after a new gasket?

    A repeat leak after a gasket replacement is usually a sign the flange itself is corroded, warped, or wasn't torqued evenly during installation. Overtightening a new gasket can also distort it and cause the same leak to return. Checking the flange surface for pitting and torquing bolts in a cross pattern typically resolves a recurring union leak.

    How long does a Z-15 cartridge seal kit typically last?

    Seal life depends heavily on water quality and how often the system cycles, so there's no single fixed interval for every installation. Systems with harder water or more mineral content tend to wear seals faster than closed loops with treated water. Replacing the seal kit any time the cartridge is opened for service, rather than waiting for a visible leak, helps avoid a repeat callback.

    Is it worth rebuilding an older Z-15 or should I replace the whole pump?

    A rebuild makes sense when the pump body and flanges are still in good condition and only the wet-rotor cartridge or motor head has failed. Once a pump has needed several rebuilds over a short period, or the housing itself shows corrosion, replacing the entire unit is usually the more practical option. Weighing the age of the installation against the parts already on hand helps make that call quickly during a service visit.