Apply to be a TradeMaster!
Filter menu expanded

Filters

460,971 items
Reset

SORT

Wilo Z-15 Pump Parts

Help Face
Need a little help?
460971 items
Grid
List
Compare
Product Image of 2" Sweat SV Combination Ball Valve, Wye Strainer and Union w/ 1-1/4" Bypass Port
$369.14 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of M-I-5036BN-11-PRE-FVIR Parts - 50 Gallon - 40,000 BTU Residential Energy Saver Gas-Upright Water Heater, Nat Gas (Pre FVIR, Series 11)not-to-sell-product
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of M12 Heated TOUGHSHELL Work Jacket (Medium) M100R-21M
$274.90 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of M12 Heated TOUGHSHELL Work Jacket (Small) M100R-21S
$274.90 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of M12 Heated Shirt Jacket, Green (XL), M103E-21XL
$219.99 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Packing (131) 506A/329A/606A/431Wta, M10B-13-14
Packing (131) 506A/329A/606A/431Wta, M10B-13-14
SKU: M10B-13-14
Rinnai
SKU: M10B-13-14
Brand: Rinnai
$1.13 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 1-1/4" NPT x 1-1/4" Male Union Horizontal Angle Valve with Straight Nipple (9000182)
$202.31 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Valve Insert for OPSK One Pipe Steam Valve
Valve Insert for OPSK One Pipe Steam Valve
SKU: MAC-OPSK-INSERT
Macon Controls
SKU: MAC-OPSK-INSERT
$49.15 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 1-1/2" Sweat URP PTV Combination Balancing Union
1-1/2" Sweat URP PTV Combination Balancing Union
SKU: MBP-URP-150S150S
Macon Balancing
SKU: MBP-URP-150S150S
$87.72 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 1" Sweat US Pressure & Temperature Measuring Balancing Union with Drain
$78.45 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of MBR1200AA-1AB Parts - MBR Ducted Multi-position Modular Blower, PSC Motor, 1200 CFM, 17-1/2" Cabinetnot-to-sell-product
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of Replacement Screw, MBRS
Replacement Screw, MBRS
SKU: MBRS
Malco
SKU: MBRS
Brand: Malco
$23.15 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of M-I-504S6BN-11-PRE-FVIR Parts - 50 Gallon - 50,000 BTU Residential Energy Saver Gas-Upright Water Heater, Nat Gas (Pre FVIR, Series 11)not-to-sell-product
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of M-I-50L10LN-11-PRE-FVIR Parts - 48 Gallon - 40,000 BTU Residential Energy Saver Gas-Upright Water Heater, Nat Gas (Pre FVIR, Series 11)not-to-sell-product
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of Maestro Fan Control & Light Dimmer for Dimmable LEDs, Incandescent, and Halogen Bulbs (Snow)
$73.16 each
In Stock
Get 62 by Fri, Nov 27 - Mon, Nov 30
In Stock
Get 62 by Fri, Nov 27 - Mon, Nov 30
Compare
Product Image of MBVC1200AA-1AA Parts - Goodman MBVC Series Multi-Position, Modular Blower Air Handler, 1200 CFMnot-to-sell-product
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of MBVC1600AA-1AF Parts - MBVC Ducted Multi-position Modular Blower, Variable Speed ECM Motor, 1600 CFM, 21" Cabinetnot-to-sell-product
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of M-I-75S10BN-PRE-FVIR Parts - 75 Gallon - 76,000 BTU High Input Atmospheric Vent Energy Saver Residential Water Heater, Nat Gas (Pre FVIR)not-to-sell-product
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of M-I-75S10CX-PRE-ICON Parts - 75 Gallon - 76,000 BTU High Input Atmospheric Vent Energy Saver Residential Water Heater -Propane (Pre ICON)not-to-sell-product
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of M-I-75S6CN-PRE-ICON Parts - 75 Gallon - 76,000 BTU High Input Atmospheric Vent Energy Saver Residential Water Heater, Nat Gas (Pre ICON)not-to-sell-product
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of Maestro 600W Electronic Low Voltage Dimmer (Light Almond)
$151.03 each
In Stock
Get 26 by Fri, Nov 27 - Mon, Nov 30
In Stock
Get 26 by Fri, Nov 27 - Mon, Nov 30
Compare
Product Image of Maestro 1000W Magnetic Low Voltage Dimmer (Black)
Maestro 1000W Magnetic Low Voltage Dimmer (Black)
SKU: MALV-1000-BL
Lutron
SKU: MALV-1000-BL
Brand: Lutron
$115.61 each
In Stock
Get 10 by Fri, Nov 27 - Mon, Nov 30
In Stock
Get 10 by Fri, Nov 27 - Mon, Nov 30
Compare
Product Image of MC24B2AH1 Parts - York Central Air Conditionernot-to-sell-product
MC24B2AH1 Parts - York Central Air Conditioner
SKU: MC24B2AH1
York
SKU: MC24B2AH1
Brand: York
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of M-I-MH40T10FLX-PRE-NAECA Parts - 40 Gallon - 34,000 BTU Manufactured Home Defender Safety System Atmospheric Vent Energy Saver Water Heater, LP Gas (Pre NAECA)not-to-sell-product
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of M-I-MH40T6FLX-PRE-NAECA Parts - 40 Gallon - 34,000 BTU Manufactured Home Defender Safety System Atmospheric Vent Energy Saver Water Heater, LP Gas (Pre NAECA)not-to-sell-product
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of M-I-TW-40L10CX-13-PRE-FVIR Parts - 40 Gallon - 40,000 BTU Defender Safety System TTW1 Residential Through-The-Wall Gas Water Heater, LP Gas (Pre FVIR, Series 13)not-to-sell-product
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of M-Switch Series Remote Switch For M-Controller Or Q4C Controller
$340.99 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of M1GH-090A-BW Parts - Nordyne Furnacenot-to-sell-product
M1GH-090A-BW Parts - Nordyne Furnace
SKU: M1GH-090A-BW
Nordyne
SKU: M1GH-090A-BW
Brand: Nordyne
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of M1MB-077A-AW Parts - Nordyne Furnacenot-to-sell-product
M1MB-077A-AW Parts - Nordyne Furnace
SKU: M1MB-077A-AW
Nordyne
SKU: M1MB-077A-AW
Brand: Nordyne
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of M1MC-090A-AW Parts - Nordyne Furnacenot-to-sell-product
M1MC-090A-AW Parts - Nordyne Furnace
SKU: M1MC-090A-AW
Nordyne
SKU: M1MC-090A-AW
Brand: Nordyne
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of M12 Heated Full-Zip Hoodie (Medium) M200G-20M
$154.99 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of M12 Heated Full-Zip Hoodie (2XL) M200G-212X
$179.99 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of M12 Heated Full-Zip Hoodie (3XL) M200G-213X
$189.99 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 5" Flanged STVA Balancing Valve
$2,343.07 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Flare Socket, MHT40969701
Flare Socket, MHT40969701
SKU: MHT40969701
LG
SKU: MHT40969701
Brand: LG
$17.99 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Lift Cover Spring, M48R925190
Lift Cover Spring, M48R925190
SKU: M48R925190
Turbo Air
SKU: M48R925190
Brand: Turbo Air
$524.44 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of Maestro Companion Dimmer Switch, Multi-Location Dimmer for Maestro Dimmers/Timers/Sensors, Not For Stand-Alone Use, Ivory
$24.07 each
Out of Stock
Get it by Tue, Dec 8 - Tue, Dec 15
Out of Stock
Get it by Tue, Dec 8 - Tue, Dec 15
Compare
Product Image of Maestro Companion Dimmer Switch, Multi-Location Dimmer for Maestro Dimmers/Timers/Sensors, Not For Stand-Alone Use, Light Almond
$24.07 each
Out of Stock
Get it by Tue, Dec 8 - Tue, Dec 15
Out of Stock
Get it by Tue, Dec 8 - Tue, Dec 15
Compare
Product Image of MA16CN31 Parts - York Air Handlernot-to-sell-product
MA16CN31 Parts - York Air Handler
SKU: MA16CN31
York
SKU: MA16CN31
Brand: York
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of Direct Mount DuraDrive Actuator (120V)
$553.03 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Power Energy Meter Bidirectional, METSEEM4236
$764.01 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of MIGHTYTHERM-1670L Parts - Boilernot-to-sell-product
MIGHTYTHERM-1670L Parts - Boiler
SKU: MIGHTYTHERM-1670L
Laars
SKU: MIGHTYTHERM-1670L
Brand: Laars
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of MIGHTYTHERM-300L Parts - Boilernot-to-sell-product
MIGHTYTHERM-300L Parts - Boiler
SKU: MIGHTYTHERM-300L
Laars
SKU: MIGHTYTHERM-300L
Brand: Laars
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of MIGHTYTHERM3600E-LP Parts - Boilernot-to-sell-product
MIGHTYTHERM3600E-LP Parts - Boiler
SKU: MIGHTYTHERM3600E-LP
Laars
SKU: MIGHTYTHERM3600E-LP
Brand: Laars
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of MIH-05NG Parts - Boilernot-to-sell-product
MIH-05NG Parts - Boiler
SKU: MIH-05NG
Peerless Boilers
SKU: MIH-05NG
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of M4AC4018R1000AA Parts - Trane M4acup5not-to-sell-product
M4AC4018R1000AA Parts - Trane M4acup5
SKU: M4AC4018R1000AA
Trane
SKU: M4AC4018R1000AA
Brand: Trane
Backorder
Get it by Mon, Feb 22 - Mon, May 17
Backorder
Get it by Mon, Feb 22 - Mon, May 17
Compare
Product Image of M4AC4060C1000AA Parts - Trane M4acup3not-to-sell-product
M4AC4060C1000AA Parts - Trane M4acup3
SKU: M4AC4060C1000AA
Trane
SKU: M4AC4060C1000AA
Brand: Trane
Backorder
Get it by Mon, Feb 22 - Mon, May 17
Backorder
Get it by Mon, Feb 22 - Mon, May 17
Compare
Product Image of M4AC6060A1000AA Parts - Trane M4ah6up2not-to-sell-product
M4AC6060A1000AA Parts - Trane M4ah6up2
SKU: M4AC6060A1000AA
Trane
SKU: M4AC6060A1000AA
Brand: Trane
Backorder
Get it by Mon, Feb 22 - Mon, May 17
Backorder
Get it by Mon, Feb 22 - Mon, May 17
Resources
FAQs, Manuals & Videos
Articles
More About Wilo Z-15 Pump Parts

Wilo Z-15 pump parts are the replacement components contractors use to service and rebuild Z-15 wet-rotor circulator pumps found in residential and light commercial hydronic heating and hot water recirculation systems. The Z-15 is a single-speed, in-line circulator, and its most commonly replaced parts are the pump head, rotor and impeller assembly, and the mounting gaskets that seal the pump body to the piping flanges. Over years of continuous operation, mineral buildup and worn bearings inside the wet-rotor cartridge are the usual reasons a Z-15 needs a rebuild rather than a full replacement. Keeping gaskets, cartridges, and mounting hardware on hand lets a contractor return a system to service the same day instead of waiting on a full pump swap, which matters most on boiler systems where extended downtime affects a building's heat.

Subcategories

  • Pump Heads: Pump heads house the motor and electrical connections for the Z-15 circulator and bolt directly onto the wet-rotor cartridge below. Contractors replace a pump head when the motor windings fail or a bad capacitor stops the rotor from starting, rather than swapping the entire unit. Because the head separates from the wet end without draining the whole system in most installations, it's often the fastest single-part repair on a Z-15. Matching the voltage and speed rating to the original nameplate keeps the replacement head compatible with the existing wiring.
  • Rotor & Impeller Assemblies: The rotor and impeller assembly is the wet-rotor cartridge that spins inside the pump body to move water through the system. Mineral scale and sediment are the most common causes of a sluggish or seized rotor, especially in older cast iron hydronic loops. Replacing the assembly restores full flow without needing to replace the pump housing or motor head. A worn sleeve bearing inside the assembly is usually what causes the humming or grinding noise contractors hear before a Z-15 fails outright.
  • Mounting Gaskets & Flanges: Mounting gaskets seal the pump body against the flanges that connect it to the supply and return piping. A worn or improperly seated gasket is one of the most common sources of a slow weep leak at the pump union. Flanges themselves rarely need replacement unless they've been damaged during a prior installation or corroded from years of exposure to boiler water. Keeping the correct gasket size on hand avoids a return trip when a routine pump service uncovers a leak at the union.
  • Cartridge Seal Kits: Cartridge seal kits bundle the O-rings and shaft seals needed to reseal the wet-rotor cartridge after it's opened for cleaning or bearing replacement. Using a complete kit instead of individual seals reduces the chance of missing a small O-ring that causes a repeat callback. Seal kits are typically sized to the specific cartridge generation, so matching the kit to the pump's production era matters more than matching it to the overall Z-15 model name alone. A fresh seal kit is standard practice any time the cartridge is removed for service, even if the old seals look intact.
  • Buying Guide

    When sourcing Wilo Z-15 pump parts, start with the failure symptom rather than guessing at a full parts list. A pump that hums but doesn't spin usually points to a seized rotor or worn bearing, calling for a rotor and impeller assembly rather than a new pump head. A pump that won't start electrically, or trips a breaker, more often points to the motor windings or capacitor inside the pump head itself. Confirm the exact age and cartridge generation of the installed unit before ordering, since Wilo has updated the internal cartridge design over the years and parts from a newer cartridge don't always fit an older pump body. For jobs where the pump has been in continuous service for many years, rebuilding with a full cartridge seal kit alongside the rotor assembly is often more efficient than replacing components piecemeal, since it addresses wear across the whole wet end in one visit. Keep a small stock of the most commonly needed Wilo Z-15 pump parts, gaskets, seal kits, and a spare pump head, on hand for routine hydronic service calls, since these are the components most likely to fail from years of continuous operation. For a pump that's failed catastrophically or is several rebuilds in already, replacing the entire unit is often the more practical long-term choice over continuing to source individual parts.

    Frequently Asked Questions

    How do I know if my Wilo Z-15 needs a new pump head or a full rotor assembly?

    If the pump is silent and doesn't spin at all, check the motor head first, since that usually points to a failed capacitor or burned winding. If the pump hums or vibrates but the rotor won't turn, the wet-rotor cartridge itself is more likely the problem. Testing continuity at the motor terminals before ordering parts helps confirm which component actually failed.

    Can I rebuild a Z-15 without draining the whole heating system?

    In most installations, the pump head separates from the wet-rotor cartridge without opening the main piping, so a motor swap doesn't require draining the loop. Replacing the cartridge, gaskets, or flanges does require isolating and draining the pump section, though the rest of the system can often stay filled if isolation valves are present. Always confirm the specific installation has isolation valves before promising a no-drain repair.

    Why does my Z-15 keep leaking at the union even after a new gasket?

    A repeat leak after a gasket replacement is usually a sign the flange itself is corroded, warped, or wasn't torqued evenly during installation. Overtightening a new gasket can also distort it and cause the same leak to return. Checking the flange surface for pitting and torquing bolts in a cross pattern typically resolves a recurring union leak.

    How long does a Z-15 cartridge seal kit typically last?

    Seal life depends heavily on water quality and how often the system cycles, so there's no single fixed interval for every installation. Systems with harder water or more mineral content tend to wear seals faster than closed loops with treated water. Replacing the seal kit any time the cartridge is opened for service, rather than waiting for a visible leak, helps avoid a repeat callback.

    Is it worth rebuilding an older Z-15 or should I replace the whole pump?

    A rebuild makes sense when the pump body and flanges are still in good condition and only the wet-rotor cartridge or motor head has failed. Once a pump has needed several rebuilds over a short period, or the housing itself shows corrosion, replacing the entire unit is usually the more practical option. Weighing the age of the installation against the parts already on hand helps make that call quickly during a service visit.