Apply to be a TradeMaster!
Filter menu expanded

Filters

207 items
Reset

SORT

Product Availability

Show In Stock Only (106)

Review Score

(34)
(1)
(2)

Price Range

$1 to $5 (1)
$5 to $10 (1)
$10 to $15 (2)
$15 to $20 (2)
$25 to $30 (1)
$30 to $35 (1)
$35 to $40 (1)
$40 to $45 (1)
$50 to $60 (1)
$60 to $70 (2)

Carrier Fan Motors & Blades

Help Face
Need a little help?
207 items
Grid
List
Compare
Product Image of Motor Fan - Outdoor, 11002012A00340
Motor Fan - Outdoor, 11002012A00340
SKU: 11002012A00340
Carrier
SKU: 11002012A00340
Brand: Carrier
$94.77 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Fan Motor, 11002015000253
Fan Motor, 11002015000253
SKU: 11002015000253
Carrier
SKU: 11002015000253
Brand: Carrier
$297.91 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Fan Propeller, LA01EC027
Fan Propeller, LA01EC027
SKU: LA01EC027
Carrier
SKU: LA01EC027
Brand: Carrier
$372.03 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Sideplate,Fan, 50HE500626
Sideplate,Fan, 50HE500626
SKU: 50HE500626
Carrier
SKU: 50HE500626
Brand: Carrier
$285.29 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Fan Blade LA01RA004
Fan Blade LA01RA004
SKU: LA01RA004
Carrier
SKU: LA01RA004
Brand: Carrier
(1)
$504.18 each
In Stock
Get 1 by Tue, Aug 18
In Stock
Get 1 by Tue, Aug 18
Compare
Product Image of Fan Blade LA01AD027
Fan Blade LA01AD027
SKU: LA01AD027
Carrier
SKU: LA01AD027
Brand: Carrier
$248.66 each
In Stock
Get 2 by Wed, Aug 19
In Stock
Get 2 by Wed, Aug 19
Compare
Product Image of Indoor Fan Panel Assembly, 48TM400573
Indoor Fan Panel Assembly, 48TM400573
SKU: 48TM400573
Carrier
SKU: 48TM400573
Brand: Carrier
$505.53 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Fan Deck, 50DK500688
Fan Deck, 50DK500688
SKU: 50DK500688
Carrier
SKU: 50DK500688
Brand: Carrier
$772.28 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 1/8 HP 208-240V 1300 RPM 3 Spd Fan Motor, 14B0010N03
$333.87 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 4-Bladed Fan Blade LA01EW025
4-Bladed Fan Blade LA01EW025
SKU: LA01EW025
Carrier
SKU: LA01EW025
Brand: Carrier
$237.56 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Fan Propeller, LA01RA051
Fan Propeller, LA01RA051
SKU: LA01RA051
Carrier
SKU: LA01RA051
Brand: Carrier
$227.64 each
Out of Stock
Get it by Tue, Sep 1 - Wed, Sep 9
Out of Stock
Get it by Tue, Sep 1 - Wed, Sep 9
Compare
Product Image of Axial Fan 630MM, 0515P-0750HT
Axial Fan 630MM, 0515P-0750HT
SKU: 0515P-0750HT
Carrier
SKU: 0515P-0750HT
Brand: Carrier
$4,057.89 each
In Stock
Get 1 by Wed, Aug 19 - Fri, Aug 21
In Stock
Get 1 by Wed, Aug 19 - Fri, Aug 21
Compare
Product Image of 208/230/460v3ph 25ton Compressor, 06ET565360
208/230/460v3ph 25ton Compressor, 06ET565360
SKU: 06ET565360
Carrier
SKU: 06ET565360
Brand: Carrier
$19,730.51 each
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Compare
Product Image of 18" CW 3-Blade Fan Blade w/ 1/2" Bore (27° Pitch), LA01EB019
$134.58 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 3-Bladed Fan Blade, 1/2" Bore - LA01EA121
3-Bladed Fan Blade, 1/2" Bore - LA01EA121
SKU: LA01EA121
Carrier
SKU: LA01EA121
Brand: Carrier
$247.26 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Resources
FAQs, Manuals & Videos
Articles
More About Carrier Fan Motors & Blades

Carrier fan motors and blades are the replacement components that move air across the condenser coil in Carrier brand air conditioning and heat pump condensing units. The fan motor drives a blade mounted above the coil, pulling outdoor air through the unit to reject heat during cooling operation. When either part wears out, a technician usually finds one of a few familiar symptoms: a motor that hums but does not spin, a blade that wobbles or has become bent from debris or storm damage, or a unit that runs louder than normal because of a worn motor bearing. Because the fan motor and blade work together as a matched pair, a replacement blade needs to fit the motor shaft correctly, and a replacement motor needs to match the original's horsepower, speed, and rotation direction. A condenser fan that stops running entirely can cause a system to overheat and shut down on high-pressure protection within minutes, making this a repair that is rarely deferred.

Subcategories

  • Condenser Fan Motors: Condenser fan motors are the electric motors that drive the outdoor unit's fan blade, typically mounted vertically on top of the condensing unit cabinet. They are specified by horsepower, rotation direction, and speed, all of which must match the original motor for the fan to move the correct volume of air. A motor that spins the wrong direction pulls air through the coil less effectively even though it still appears to be running. Technicians confirm shaft length and diameter as well, since a mismatched shaft prevents the blade from seating correctly.
  • Condenser Fan Blades: Condenser fan blades attach to the motor shaft and move air across the coil as they spin, and they take the brunt of physical damage from storms, falling debris, and general wear over years of outdoor exposure. A bent or chipped blade throws off the fan's balance, leading to vibration that can eventually damage the motor bearing it is attached to. Blades are sized by diameter and pitch to match both the motor and the airflow requirements of the specific condensing unit. Replacing a damaged blade before it damages the motor is generally the more economical repair.
  • Motor Mounting Brackets and Hardware: Mounting brackets, fan grilles, and related hardware secure the motor and blade assembly inside the condensing unit cabinet and keep the fan properly aligned above the coil. Corrosion from years of outdoor exposure is a common reason these parts need replacement even when the motor and blade themselves are still functional. Using the correct bracket keeps the fan blade centered within its housing, which matters for both airflow and safety clearance from the blade tips. Replacing corroded hardware during a motor or blade swap avoids a repeat service call.

Buying Guide

Replacing a Carrier condenser fan motor starts with recording the original motor's horsepower, rotation direction, and speed from its nameplate, since all three need to match for the new motor to move the correct volume of air across the coil in the correct direction. A motor that looks similar but spins the opposite direction will run and sound normal while still failing to cool the unit effectively, which makes this detail easy to miss without checking the nameplate directly.

Shaft dimensions matter just as much as electrical specifications. The motor shaft's diameter and length need to match what the fan blade is designed to mount onto, and the mounting bracket needs to fit the specific condensing unit's cabinet. Measuring the original motor before ordering, rather than relying on the unit's overall model number alone, reduces the chance of ordering a part that does not physically install.

When only the blade needs replacement, matching diameter and pitch to the original is the priority, since a blade that is too small moves less air than the system needs, while one that is too large or has a different pitch can create a load the motor was not designed to handle. Inspecting the blade for bends or chips regularly, particularly after storms, allows a technician to catch and correct a balance problem before it damages the motor. Ordering motor and blade together as a set is often the more efficient approach when both show signs of wear, since a worn motor and a slightly imbalanced blade frequently fail around the same time.

Frequently Asked Questions

What causes a Carrier condenser fan motor to hum but not spin?

A humming motor that does not turn is often caused by a failed start capacitor, a worn bearing that has locked up, or a mechanical obstruction blocking the blade. Checking for debris around the blade first is a quick way to rule out the simplest cause. If the blade spins freely by hand but the motor still will not start on its own, the motor or its capacitor is the more likely culprit.

Why does rotation direction matter when replacing a condenser fan motor?

The fan blade is designed to move air in one direction as it spins, and a motor running the wrong direction still turns and sounds normal while failing to pull air through the coil effectively. This can cause a system to run poorly or overheat even though nothing appears visibly wrong from outside the unit. Confirming rotation direction on the nameplate before installation avoids this issue.

Can a bent fan blade be straightened instead of replaced?

A slightly bent blade might spin without obvious problems, but any bend throws off the blade's balance and creates vibration that can eventually damage the motor bearing. Because blades are relatively inexpensive compared to a motor, replacing a bent or chipped blade outright is generally a more reliable fix than attempting to straighten it. Inspecting the blade after any storm event is good practice.

How is horsepower determined when ordering a replacement condenser fan motor?

The original motor's nameplate lists its horsepower rating, and this figure needs to match the replacement for the fan to move the correct volume of air across the coil. Undersized motors can overheat trying to move air they are not built to handle, while oversized motors may not fit the mounting bracket or draw more current than the circuit is designed for. Recording the nameplate information before ordering is the most reliable approach.

Should the motor and blade always be replaced together?

Not always, but when both show signs of wear it is often more efficient to replace them as a set, since a worn motor and a slightly imbalanced blade frequently reach the end of their service life around the same time. If only one part has failed and the other is confirmed to be in good condition, replacing just the failed component is a reasonable approach. Inspecting both parts during any fan service call helps make that determination.

Didn't find what you're looking for? 
Let us know
.