Apply to be a TradeMaster!
Filter menu expanded

Filters

1,030 items
Reset

SORT

Product Availability
–

Show In Stock Only (133)

Price Range
–

$1 to $5 (2)
$5 to $10 (18)
$10 to $15 (8)
$15 to $20 (9)
$20 to $25 (18)
$25 to $30 (13)
$30 to $35 (14)
$35 to $40 (15)
$40 to $45 (16)
$45 to $50 (24)

ClimateMaster Parts - Heat Pump

Help Face
Need a little help?
1030 items
Grid
List
Compare
Product Image of Control Box Subbase High Voltage, 45F0190GNN
$21.24 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Programmed ECM Motor Assembly, S14S0019N23
$821.41 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of Taco Pump, 24B0033N02
Taco Pump, 24B0033N02
SKU: 24B0033N02
ClimateMaster
SKU: 24B0033N02
$377.67 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Control Board, 17B0056N02
Control Board, 17B0056N02
SKU: 17B0056N02
ClimateMaster
SKU: 17B0056N02
$865.58 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of O-ring Un075, 29B0016N01
O-ring Un075, 29B0016N01
SKU: 29B0016N01
ClimateMaster
SKU: 29B0016N01
$6.88 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 3ht/2cl Programmable Thermostat, ATP32U06
$514.29 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of Programmed ECM Blower motor, S14S0017N08
$590.85 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 3/4hp 2spd Motor, 14B0006N04
3/4hp 2spd Motor, 14B0006N04
SKU: 14B0006N04
ClimateMaster
SKU: 14B0006N04
$328.59 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of Element Wrench Tool, 29B0203N09
Element Wrench Tool, 29B0203N09
SKU: 29B0203N09
ClimateMaster
SKU: 29B0203N09
$42.84 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Expansion Valve, 33B0058N02
Expansion Valve, 33B0058N02
SKU: 33B0058N02
ClimateMaster
SKU: 33B0058N02
$241.32 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Rear Compressor Wrapper, 44F3534GFB
$128.98 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Harness Power All 65" Tsm24-42, 11B0100N18
$54.75 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 208/230v 1ph Compressor, 33B0048N01
$651.85 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Fuse Type Lp-cc 600v 1.5amp, 16B0017N04
$79.30 each
In Stock
Get 9 by Tue, Oct 6
In Stock
Get 9 by Tue, Oct 6
Compare
Product Image of 3/4" Hose Kit, AHH0753B
3/4" Hose Kit, AHH0753B
SKU: AHH0753B
ClimateMaster
SKU: AHH0753B
$107.63 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 24v 3-way 1" Valve, 23B0086N02
24v 3-way 1" Valve, 23B0086N02
SKU: 23B0086N02
ClimateMaster
SKU: 23B0086N02
$1,660.11 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 12kw Heater Element, 18B0005N01
12kw Heater Element, 18B0005N01
SKU: 18B0005N01
ClimateMaster
SKU: 18B0005N01
$154.25 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 230/1/60 Scroll Compressor, 34B0163N01S
$2,728.76 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of 1"fpt X 5/8" Swt, 90B0002N01
1"fpt X 5/8" Swt, 90B0002N01
SKU: 90B0002N01
ClimateMaster
SKU: 90B0002N01
$39.71 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Coax Coil, S62B0013N13
Coax Coil, S62B0013N13
SKU: S62B0013N13
ClimateMaster
SKU: S62B0013N13
$3,836.05 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Receiver / Muffler, 36B0006N10
Receiver / Muffler, 36B0006N10
SKU: 36B0006N10
ClimateMaster
SKU: 36B0006N10
$38.29 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Hose Kit, AHC0752-0900
Hose Kit, AHC0752-0900
SKU: AHC0752-0900
ClimateMaster
SKU: AHC0752-0900
$369.60 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 24" Cased Air Coil, TAC038BM24S
24" Cased Air Coil, TAC038BM24S
SKU: TAC038BM24S
ClimateMaster
SKU: TAC038BM24S
$2,023.19 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Eev Stator E2v 0.3, 33B0040N01
Eev Stator E2v 0.3, 33B0040N01
SKU: 33B0040N01
ClimateMaster
SKU: 33B0040N01
$168.49 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 75hp Heat Pump Cond,208-230,1p, TCH009AGC30CLSS
75hp Heat Pump Cond,208-230,1p, TCH009AGC30CLSS
SKU: TCH009AGC30CLSS
ClimateMaster
SKU: TCH009AGC30CLSS
$3,233.90 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Air Coil, 61B0113N55
Air Coil, 61B0113N55
SKU: 61B0113N55
ClimateMaster
SKU: 61B0113N55
$1,453.45 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Harness, 11B0011N03
Harness, 11B0011N03
SKU: 11B0011N03
ClimateMaster
SKU: 11B0011N03
$31.42 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 1" X 2" Hose Kit, AHA1002
1" X 2" Hose Kit, AHA1002
SKU: AHA1002
ClimateMaster
SKU: AHA1002
$312.54 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Ea Motor 1/5hp, 3 speed Kit, S14P0002N01
$596.13 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Ttv Door, 41F0465GFC
Ttv Door, 41F0465GFC
SKU: 41F0465GFC
ClimateMaster
SKU: 41F0465GFC
$75.63 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Hose Kit, AHS0752
Hose Kit, AHS0752
SKU: AHS0752
ClimateMaster
SKU: AHS0752
$288.82 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Field Kit w/ tah Revision A, S11S0009N04
$77.10 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Elecrtic Kit, S69887300
Elecrtic Kit, S69887300
SKU: S69887300
ClimateMaster
SKU: S69887300
$427.13 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Climate Master Unit, TRH009AGC35CCSS
Climate Master Unit, TRH009AGC35CCSS
SKU: TRH009AGC35CCSS
ClimateMaster
SKU: TRH009AGC35CCSS
$4,418.98 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Air Coil, 61B0077N01
Air Coil, 61B0077N01
SKU: 61B0077N01
ClimateMaster
SKU: 61B0077N01
$1,266.80 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Muffler, 68170201
Muffler, 68170201
SKU: 68170201
ClimateMaster
SKU: 68170201
$59.57 each
In Stock
Get 3 by Tue, Oct 6
In Stock
Get 3 by Tue, Oct 6
Compare
Product Image of 29.53"x31.875"x2" Merv11, 76B0005N19
$124.32 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of R-410a 60hz 3ph 200/230v Comp, 34B0171N03
$1,314.38 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Control Box Low Voltage, 45F0189GNN
$36.85 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of ECM Motor, S14S0019N09
ECM Motor, S14S0019N09
SKU: S14S0019N09
ClimateMaster
SKU: S14S0019N09
$677.72 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Outdoor Sensor, AST008
Outdoor Sensor, AST008
SKU: AST008
ClimateMaster
SKU: AST008
$47.04 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Belt Linkage, 696-006
Belt Linkage, 696-006
SKU: 696-006
ClimateMaster
SKU: 696-006
$426.55 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Heating Element Gasket, 29B0203N07
Heating Element Gasket, 29B0203N07
SKU: 29B0203N07
ClimateMaster
SKU: 29B0203N07
$14.95 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 5kw Duct Heater, AH05GS
$463.89 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Harness,tstat Ada D, 11B0100N17
Harness,tstat Ada D, 11B0100N17
SKU: 11B0100N17
ClimateMaster
SKU: 11B0100N17
$66.62 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Front Panel, 41F0306AFP
Front Panel, 41F0306AFP
SKU: 41F0306AFP
ClimateMaster
SKU: 41F0306AFP
$160.80 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of R22 Upgrade Kit, EUKGS070
R22 Upgrade Kit, EUKGS070
SKU: EUKGS070
ClimateMaster
SKU: EUKGS070
$1,230.33 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Compressor Overload, 16B0009N43
Compressor Overload, 16B0009N43
SKU: 16B0009N43
ClimateMaster
SKU: 16B0009N43
$38.28 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Resources
FAQs, Manuals & Videos
Articles
More About ClimateMaster Parts

ClimateMaster parts support the water source and geothermal heat pump systems ClimateMaster builds for residential and commercial buildings, which use the stable underground or water-loop temperature instead of outdoor air to heat and cool. Because these systems trade an outdoor condenser for a ground loop or water loop, the compressor, coaxial heat exchanger, and reversing valve inside the indoor cabinet see more consistent operating conditions than a typical air source system, but they still wear over the equipment's service life. ClimateMaster indoor units are commonly rated for service lives well beyond twenty years, with ground loops lasting even longer, which means a shop servicing these systems is often working on equipment that has outlasted several other components in the building. Confirming the exact model and cabinet configuration before ordering matters more with geothermal equipment than with standard split systems, since parts are less commonly interchangeable across model families. Stocking the parts specific to the ClimateMaster models a service area has installed in volume avoids ordering delays on time-sensitive repairs.

Subcategories

  • Compressors: The compressor in a water source or geothermal heat pump circulates refrigerant between the coaxial heat exchanger and the indoor coil, and it typically runs under steadier load conditions than an air source compressor since ground or water loop temperatures fluctuate less than outdoor air. Confirming the exact compressor model against the unit's nameplate is important since ClimateMaster has produced multiple cabinet and capacity configurations. Compressor replacement is one of the higher cost repairs on these systems. A failed compressor often shows up alongside a high-pressure or low-pressure fault code on the unit's controls.
  • Control Boards: Control boards manage compressor operation, fan staging, and safety lockouts, and a fault here can affect multiple functions at once depending on which board and function are involved. Boards are model and revision specific, so confirming the exact unit configuration before ordering avoids a mismatch. These systems often log fault codes that point toward a specific board or sensor issue, which narrows down troubleshooting compared to a simple no-cool complaint. Power quality issues are a common contributor to board failures in commercial installations.
  • Reversing Valves: The reversing valve switches the system between heating and cooling mode by redirecting refrigerant flow, and a failure here typically shows the system stuck in one mode regardless of the thermostat call. This is a moderately involved repair that requires refrigerant recovery and recharge, so it is not a quick parts swap. A reversing valve that fails to fully shift, rather than failing outright, can sometimes be mistaken for a control or sensor issue during initial diagnosis. Confirming the valve is the actual point of failure before ordering avoids replacing a working part.
  • Water Coils and Coaxial Heat Exchangers: The coaxial heat exchanger transfers heat between the refrigerant circuit and the water or ground loop, and buildup of scale or debris in the water loop over time can reduce its efficiency even without an outright failure. These parts see less exposure to outdoor contaminants than an air source coil, but water quality in the loop itself becomes the main variable affecting their condition. Confirming loop water quality and flow rate is a useful diagnostic step before assuming the heat exchanger itself has failed. Replacement is a more involved repair than most parts on this list due to the plumbing connections involved.

Buying Guide

Confirm the exact model number and cabinet configuration from the unit's nameplate before ordering, since ClimateMaster has produced multiple product families across residential and commercial applications and parts are not always interchangeable between them.

Read any fault codes displayed on the unit's control board before assuming which part has failed. These systems typically log codes tied to specific functions such as high pressure, low pressure, or sensor faults, which narrows the diagnosis considerably compared to a general no-heat or no-cool complaint.

When sourcing ClimateMaster Parts for a commercial building, confirm whether the loop is a shared water loop or dedicated ground loop system, since water quality and flow conditions differ between the two and affect which components see the most wear over time.

Because these systems have longer service lives than typical air source equipment, expect to service units that are considerably older than a comparable split system still in the field. Confirming current parts availability for an older model before committing to a repair versus a full unit replacement is a worthwhile step on aging installations.

Rule out water loop quality issues before replacing a coaxial heat exchanger outright, since scale or debris buildup in the loop can reduce performance without the part itself having failed.

Frequently Asked Questions

How long do ClimateMaster geothermal systems typically last compared to standard air source equipment?

Indoor units are commonly rated for service lives beyond twenty years, and ground loops can last more than fifty years, which is considerably longer than a typical air source system. This means service techs are often working on older equipment than they would encounter with standard split systems.

What is the difference between a water source and geothermal heat pump system?

Both trade an outdoor air source condenser for a water or ground loop, but a geothermal system uses buried ground loops while a water source system typically uses a shared water loop within a building. The core compressor, valve, and heat exchanger components serve the same function in both configurations.

Why does water loop quality matter for parts longevity?

The coaxial heat exchanger and other water-side components are directly exposed to whatever is circulating in the loop, so scale, debris, or poor water treatment can reduce component life and efficiency even without an outright failure. Checking loop water quality is a useful step before replacing a heat exchanger.

Can a fault code narrow down which part has failed?

Yes, ClimateMaster control boards typically log fault codes tied to specific conditions such as high pressure, low pressure, or sensor faults, which helps narrow diagnosis to a specific component rather than starting from a general no-heat or no-cool complaint.

Is a reversing valve failure always a full valve replacement?

Not necessarily. A valve that fails to fully shift between modes can sometimes resemble a control or sensor issue, so confirming the valve itself is the actual point of failure before ordering a replacement avoids swapping a part that was not actually broken.