Apply to be a TradeMaster!
Filter menu expanded

Filters

55 items
Reset

SORT

Product Availability
–

Show In Stock Only (23)

Product Type
–

Backflow Preventer (26)
1st Check Repair Kit (6)
2nd Check Repair Kit (6)
1st or 2nd Check Repair Kit (4)
Rubber Repair Kit (9)
Total Repair Kit (3)

Size
–

1/2" (3)
3/4" (4)
1" (4)
1-1/4" (3)
1-1/2" (5)
2" (5)
2-1/2" (2)
3" (3)

Connection Type
–

Female Threaded (16)
Flanged x Flanged (5)
Press (5)

Material
–

Cast Bronze (17)
Cast Copper (2)
Cast Iron (5)
Copper Silicon Alloy (2)

Used With
–

1/2" Watts 007 (2)
3/4" Watts 007 (13)
1" Watts 007 (6)
1-1/4" Watts 007 (4)
1-1/2" Watts 007 (11)
2" Watts 007 (7)

Review Score
–

(20)

Price Range
–

$40 to $45 (2)
$45 to $50 (2)
$50 to $60 (4)
$60 to $70 (2)
$70 to $80 (1)
$80 to $90 (2)
$100 to $200 (8)
$200 to $300 (6)
$300 to $400 (4)
$400 to $500 (5)

Watts 007 Double Check Valve Assemblies

Help Face
Need a little help?
55 items
Grid
List
Compare
Product Image of 2nd Check Repair Kit for Watts 1-1/4" - 1-1/2" 007 (RK-007M2-CK2)
$204.69 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of 2nd Check Repair Kit for Watts 1-1/2" - 2" 007 (RK-007-CK2)
$217.29 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of 2nd Check Repair Kit for Watts 1-1/2" -2" 007 (RK-007M1-CK2)
$167.73 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of Double Check Valve Assembly Total Repair Kit for 1-1/4" to 1-1/2" 719 (RK-719)
$281.75 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of Double Check Valve Total Repair Kit for Watts 1-1/2" & 2" (RK 007-T)
$420.06 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of 1-1/2" and 2" Double Check Valve Total Repair Kit for 007M1
$357.26 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of 1" 007M1-QT-CT-FZ Double Check Valve Assembly, Cap and Tether w/ Freeze Sensor
$268.65 each
In Stock
Get 1 by Mon, Nov 23
In Stock
Get 1 by Mon, Nov 23
Resources
FAQs, Manuals & Videos
Articles
More About Watts 007 Double Check Valve Assemblies

Watts 007 double check valve assemblies are backflow preventers built to stop contaminated water from siphoning back into a potable supply line on irrigation, fire protection, and light commercial systems. Each assembly pairs two independently acting check valves with shutoff valves on both ends, letting a contractor isolate and test the unit without draining the whole line. The Watts 007 series is certified to ASSE Std. 1015, has a bronze body rated for a maximum working pressure of 175 psi, and covers sizes from 1/2 inch to 2 inch for most residential and light commercial installs. Because backflow testing is required annually in most jurisdictions, an assembly with accessible, resilient-seated test cocks keeps future inspections quick and keeps the system code compliant. Reliable certification paired with a serviceable design is why the 007 remains a common specification on cross-connection control jobs across plumbing and irrigation trades.

Subcategories

  • Compact 1/2 to 1 Inch Assemblies: Smaller-diameter 007 assemblies fit tight mechanical rooms and irrigation meter pits on single-family and light commercial jobs. Plumbers and irrigation contractors favor this size range for domestic booster lines and yard sprinkler feeds where local code calls for backflow protection. The compact bronze body still carries the full ASSE Std. 1015 certification, so it satisfies the same inspection requirements as the larger sizes.
  • 1 1/4 to 2 Inch Assemblies: Larger 007 assemblies handle higher flow volumes on commercial irrigation mains, standpipe supply lines, and multi-unit domestic services. Contractors spec these sizes when a single meter or riser feeds several buildings or a larger landscaped area. The bronze body and 175 psi working pressure rating hold up under the higher demand these systems place on the assembly.
  • Repair Kits and Test Cocks: Because most jurisdictions require annual backflow testing, keeping rebuild kits and replacement test cocks on hand shortens downtime during inspection season. Service techs use these kits to rebuild the check modules in place instead of replacing the whole assembly. Resilient-seated test cocks are the parts that see the most wear from repeated gauge connections.
  • Freeze-Resistant Models: Watts also offers 007 assemblies with an integrated freeze sensor that works with SentryPlus Alert technology to warn facility staff when the unit nears freezing temperatures. Building owners in cold climates use these models on exposed or unheated mechanical spaces where a frozen assembly would shut down the water supply. The sensor adds a layer of protection beyond the standard bronze body's own cold-weather tolerance.
  • Buying Guide

    Sizing is the first decision on any backflow job: match the assembly to the meter or pipe size feeding the line rather than rounding up, since an oversized double check valve can create excess pressure loss. Next, confirm the local water authority's approval list; most municipalities only accept assemblies certified to ASSE Std. 1015 or the equivalent AWWA C510 standard, and Watts 007 double check valve assemblies meet both. Installation location matters just as much as sizing. A unit mounted where a tester can reach all four test cocks without draining nearby equipment saves real time on the annual inspection every assembly requires by code. For cold climates or exposed mechanical rooms, weigh the freeze-sensor option against a standard model. The added protection costs little compared to the cost of a frozen or cracked assembly mid-winter. Commercial fire and irrigation systems with higher flow demands should move up to the 1 1/4 inch to 2 inch range rather than running a smaller assembly at its rated maximum, which shortens valve life and increases maintenance calls. Finally, stock basic repair parts, resilient-seated test cocks and rebuild kits, alongside the assembly itself. Testing companies often flag worn seats during the first annual inspection, and having the parts on the truck avoids a second site visit. Buying the assembly and its common wear parts together keeps a backflow program running with fewer callbacks.

    Frequently Asked Questions

    What is a double check valve assembly used for?

    It prevents potable water from being contaminated by backflow from irrigation, fire protection, or commercial process piping. Two independent check valves stop reverse flow even if one valve fails to seat fully.

    Does the Watts 007 need to be tested every year?

    Most water authorities require annual testing of any installed backflow assembly, including the 007 series. Local code enforcement, not the manufacturer, sets the exact testing interval, so confirm requirements with the jurisdiction before scheduling.

    What size Watts 007 assembly do I need?

    Match the assembly size to the pipe or meter it's protecting rather than oversizing it. The 007 series covers 1/2 inch through 2 inch, which fits most residential and light commercial applications.

    Can the Watts 007 be repaired instead of replaced?

    Yes. Rebuild kits and replacement test cocks are available so a service tech can restore a worn assembly in place. Replacing the whole unit is usually only necessary if the bronze body itself is damaged.

    Is a freeze sensor necessary on every installation?

    It's not required by code, but it's worth adding on assemblies installed in unheated mechanical rooms or exposed outdoor locations. The sensor alerts staff before freezing temperatures can crack the assembly and interrupt water service.