Watts 007 double check valve assemblies are backflow preventers built to stop contaminated water from siphoning back into a potable supply line on irrigation, fire protection, and light commercial systems. Each assembly pairs two independently acting check valves with shutoff valves on both ends, letting a contractor isolate and test the unit without draining the whole line. The Watts 007 series is certified to ASSE Std. 1015, has a bronze body rated for a maximum working pressure of 175 psi, and covers sizes from 1/2 inch to 2 inch for most residential and light commercial installs. Because backflow testing is required annually in most jurisdictions, an assembly with accessible, resilient-seated test cocks keeps future inspections quick and keeps the system code compliant. Reliable certification paired with a serviceable design is why the 007 remains a common specification on cross-connection control jobs across plumbing and irrigation trades.
Subcategories
Buying Guide
Sizing is the first decision on any backflow job: match the assembly to the meter or pipe size feeding the line rather than rounding up, since an oversized double check valve can create excess pressure loss. Next, confirm the local water authority's approval list; most municipalities only accept assemblies certified to ASSE Std. 1015 or the equivalent AWWA C510 standard, and Watts 007 double check valve assemblies meet both. Installation location matters just as much as sizing. A unit mounted where a tester can reach all four test cocks without draining nearby equipment saves real time on the annual inspection every assembly requires by code. For cold climates or exposed mechanical rooms, weigh the freeze-sensor option against a standard model. The added protection costs little compared to the cost of a frozen or cracked assembly mid-winter. Commercial fire and irrigation systems with higher flow demands should move up to the 1 1/4 inch to 2 inch range rather than running a smaller assembly at its rated maximum, which shortens valve life and increases maintenance calls. Finally, stock basic repair parts, resilient-seated test cocks and rebuild kits, alongside the assembly itself. Testing companies often flag worn seats during the first annual inspection, and having the parts on the truck avoids a second site visit. Buying the assembly and its common wear parts together keeps a backflow program running with fewer callbacks.
Frequently Asked Questions
What is a double check valve assembly used for?
It prevents potable water from being contaminated by backflow from irrigation, fire protection, or commercial process piping. Two independent check valves stop reverse flow even if one valve fails to seat fully.
Does the Watts 007 need to be tested every year?
Most water authorities require annual testing of any installed backflow assembly, including the 007 series. Local code enforcement, not the manufacturer, sets the exact testing interval, so confirm requirements with the jurisdiction before scheduling.
What size Watts 007 assembly do I need?
Match the assembly size to the pipe or meter it's protecting rather than oversizing it. The 007 series covers 1/2 inch through 2 inch, which fits most residential and light commercial applications.
Can the Watts 007 be repaired instead of replaced?
Yes. Rebuild kits and replacement test cocks are available so a service tech can restore a worn assembly in place. Replacing the whole unit is usually only necessary if the bronze body itself is damaged.
Is a freeze sensor necessary on every installation?
It's not required by code, but it's worth adding on assemblies installed in unheated mechanical rooms or exposed outdoor locations. The sensor alerts staff before freezing temperatures can crack the assembly and interrupt water service.