EMT Non-Insulated Compression Connectors are the fittings that bond electrical metallic tubing to boxes and enclosures. RACO's noninsulated steel connectors are zinc-electroplated for added corrosion protection, and the 1 inch and 2 inch models are cULus Listed to UL 514B. The compression design makes a concrete-tight connection, so the fitting suits runs where concrete contact is a concern. RACO lists the line in trade sizes from 1/2 inch through 4 inch, so one family can match everything from small to large conduit. Contractors compare trade size, material, and listing to the conduit run before they order. Steel construction adds mechanical protection at the point where conduit meets the box. Choosing the right connector keeps the raceway mechanically secure and properly bonded at every box, which protects the installation, speeds inspection, and helps avoid callbacks.
Subcategories
Buying Guide
Start with the conduit. Match the connector trade size to the EMT on the run, because RACO lists trade sizes from 1/2 inch through 4 inch and each connector is sized for its own tubing. Next, confirm the listing. RACO's 1 inch 2904 and 2 inch 2908 are cULus Listed to UL 514B, which is worth checking against the project spec. Then decide on throat style. A noninsulated design, as on these RACO connectors, has no insulated throat, so read the job spec to see whether the conductors need separate protection at the box. Consider construction as well. Steel with a zinc-electroplated finish adds mechanical protection and corrosion protection at the box connection, and the compression design gives a concrete-tight connection. When comparing EMT Non-Insulated Compression Connectors, check pack quantity too. RACO sets a minimum pack of 25 and a carton of 100 for the 2904, while the 2908 comes in cartons of 20, so ordering by the carton can simplify staging for a rough-in. Finally, check whether the project carries Buy America(n) requirements. RACO lists the 2904 as Buy America(n) Qualified, which can simplify purchasing paperwork. Verify the final count and part numbers against the takeoff before ordering. Mixing sizes on one order is common, so list each trade size separately on the purchase order.
Frequently Asked Questions
What trade sizes do EMT non-insulated compression connectors come in?
RACO lists its EMT non-insulated compression connectors in trade sizes from 1/2 inch through 4 inch. The 1 inch 2904 and the 2 inch 2908 are two examples. Match the connector size to the EMT trade size on the run.
Are non-insulated EMT compression connectors UL listed?
RACO's 2904 and 2908 non-insulated EMT compression connectors are cULus Listed and carry UL 514B. Check the listing for the specific part number before ordering for a job with a strict spec.
What are RACO non-insulated EMT compression connectors made of?
RACO non-insulated EMT compression connectors are steel with a zinc-electroplated finish. The steel adds mechanical protection, and the zinc finish adds corrosion protection. The 2904 and 2908 listings both show this construction.
Do compression connectors for EMT make a concrete-tight connection?
RACO states that its non-insulated EMT compression connectors provide concrete-tight connections. The connectors also bond EMT conduit to the box or enclosure, so one fitting handles both jobs. Confirm the project spec for the environment before choosing.
How many non-insulated EMT compression connectors come in a carton?
Pack size depends on the part number. RACO lists the 1 inch 2904 with a minimum pack of 25 and a carton of 100, and the 2 inch 2908 in cartons of 20. Check the product page for the exact pack quantity on EMT non-insulated compression connectors.