Emerson Flow Controls solenoid valves are coil-operated shutoff valves that open and close a line on an electrical signal. The listings cover 2-way, normally closed designs in direct-acting and pilot-operated styles, with ODF and threaded connections. The 200RB is a pilot-operated, 2-way, normally closed valve used for liquid, discharge, or suction gas refrigerant service. The 240RA is a normally closed diaphragm valve used for liquid, suction, and hot gas service, and one coil fits all valve sizes in the 240RA line. The 204CD is a direct-acting, unidirectional, normally closed valve for air, water, and steam applications, with a maximum working pressure of 500 psi. Matching the valve style, service, and connection to the system keeps a control point dependable and reduces callbacks from a mismatched part.
Subcategories
Buying Guide
Start with the fluid and the service. Liquid, discharge, and suction gas refrigerant lines point to the 200RB, and liquid, suction, and hot gas service points to the 240RA. Air, water, and steam applications point to the 204CD. Confirm the listed service on the product record first, since a valve chosen for the wrong fluid has to be replaced.
Next, match the connection and the flow. The 240RA can be brazed into the line without disassembly. Threaded valves, such as the 204CD in a 1/4" NPT size, suit piping built with threaded fittings. Compare the connection size, orifice size, and flow capacity. The 204CD is rated at 0.48 Cv, and a 3/8" pipe size model with a 1/4" orifice is rated at 1 Cv, so the connection size alone doesn't set capacity.
When comparing Emerson Flow Controls solenoid valves, check the pressure rating, body material, and options. The 204CD lists a maximum working pressure of 500 psi and brass or stainless steel bodies. The 200RB comes in 8 orifice sizes with manual stem or mounting stud options, and mounting stud models on the 240RA can be field converted to manual stem. Last, confirm coil voltage against the control circuit. The 204CD lists optional voltages including 12 or 24 VDC, and one coil fits all valve sizes on the 200RB and 240RA.
Frequently Asked Questions
What's the difference between direct-acting and pilot-operated solenoid valves here?
Both styles are listed among Emerson Flow Controls solenoid valves. The 204CD is a direct-acting, unidirectional, normally closed valve for air, water, and steam, while the 200RB is a pilot-operated, 2-way, normally closed valve for liquid, discharge, or suction gas refrigerant service. Check the style and the service together before picking a model.
Are these solenoid valves normally closed?
The 200RB, 240RA, and 204CD are all normally closed valves within Emerson Flow Controls solenoid valves. The 3/8" by 1/4" direct-acting model rated at 1 Cv is a 2-way, normally closed valve too. Confirm the position on each product record before ordering.
Can I braze the valve into the line without taking it apart?
On the 240RA, yes. The 240RA is a 2-way, normally closed diaphragm valve that can be brazed into the line without disassembly, and its PTFE diaphragm is for high temperature applications. Check the product record for any other Emerson Flow Controls solenoid valves before assuming the same.
Does one coil fit all the valve sizes?
On the 200RB and 240RA lines, one coil fits all valve sizes. Emerson Flow Controls solenoid valves in those lines also use long-life molded coils. The 204CD lists optional voltages including 12 or 24 VDC, so match the voltage to the control circuit.
What pressure can the 204CD handle?
The 204CD, one of the Emerson Flow Controls solenoid valves listed here, has a maximum working pressure of 500 psi. It's a direct-acting, unidirectional, normally closed valve for air, water, and steam, and it comes in brass or stainless steel bodies. Repair kits are listed for the 204CD.