Apply to be a TradeMaster!
Filter menu expanded

Filters

454 items
Reset

SORT

Product Availability
–

Show In Stock Only (363)

Horse Power
–

1/30 (1)
1/25 (1)
1/20 (2)
1/15 (1)
1/12 (2)
1/10 (11)
1/8 (1)
1/6 (11)
1/5 (10)
1/4 (19)

RPM
–

825 (17)
1050 (6)
1060 (2)
1075 (26)
1080 (1)
1120 (1)
1140 (1)
1200 (1)
1550 (1)
1625 (1)

Voltage
–

115V (26)
120v (5)
240v (8)
460v (36)
570V (1)
575v (3)
115/230V (1)
120/240V (2)
200/230/460v (1)
200v (1)

Speeds
–

2 (4)
3 (3)
4 (1)
5 (2)
Variable (2)

Review Score
–

(98)
(2)
(2)
(3)
(1)

Price Range
–

$5 to $10 (2)
$10 to $15 (3)
$20 to $25 (5)
$25 to $30 (3)
$30 to $35 (2)
$35 to $40 (3)
$40 to $45 (2)
$45 to $50 (2)
$50 to $60 (4)
$60 to $70 (2)

Lennox Draft Blowers and Motors

Help Face
Need a little help?
454 items
Grid
List
Compare
Product Image of 1/2 HP Motor 1075 RPM (208/230v), 78F90
$760.21 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Inducer Hose Kit, 77M50
Inducer Hose Kit, 77M50
SKU: 77M50
Lennox
SKU: 77M50
Brand: Lennox
$126.10 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Motor Mount Grommet Kit, 50W88
Motor Mount Grommet Kit, 50W88
SKU: 50W88
Lennox
SKU: 50W88
Brand: Lennox
$11.99 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Blower V-Belt, BX62, 65" O.C, 57A77
$85.38 each
In Stock
Get 3 by Tue, Nov 24
In Stock
Get 3 by Tue, Nov 24
Compare
Product Image of 1/3 HP CCW Blower Motor (250-1250 RPM), 59W37
$609.70 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 1 HP 1PH Condenser Fan Motor (230v), 88C74
$723.43 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 8 3/4"od 1 3/16"bore Blower Pully, 58C62
$186.98 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Hepa Motor Assembly, X2669
Hepa Motor Assembly, X2669
SKU: X2669
Lennox
SKU: X2669
Brand: Lennox
(1)
$715.25 each
In Stock
Get 4 by Tue, Nov 24
In Stock
Get 4 by Tue, Nov 24
Compare
Product Image of 1 HP 1-Phase Blower Motor (120-240V), 10U42
$927.91 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of 1/4hp 240v Blower Motor, 12W65
1/4hp 240v Blower Motor, 12W65
SKU: 12W65
Lennox
SKU: 12W65
Brand: Lennox
$329.86 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of Blower Motor Mount, 17L41
Blower Motor Mount, 17L41
SKU: 17L41
Lennox
SKU: 17L41
Brand: Lennox
$347.20 each
In Stock
Get 2 by Mon, Nov 23
In Stock
Get 2 by Mon, Nov 23
Compare
Product Image of Orifice For Draft Inducer, 18J15
Orifice For Draft Inducer, 18J15
SKU: 18J15
Lennox
SKU: 18J15
Brand: Lennox
$27.60 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of Cai Comb-Motor Kit Psc 1-Stg, 23A35
$361.45 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of Motor-Fan 1/5 HP 230V 60Hz 825Rpm, 23V41
$412.75 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Compare
Product Image of 1/6 HP 1-Phase CCWLE Blower Motor (1075 RPM, 460V), 25W17
$322.73 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of Inducer Plate, 26W03
Inducer Plate, 26W03
SKU: 26W03
Lennox
SKU: 26W03
Brand: Lennox
$220.98 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of Collector Box Plate, 26W04
Collector Box Plate, 26W04
SKU: 26W04
Lennox
SKU: 26W04
Brand: Lennox
$449.48 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of 1 Phase Motor (1/10 HP, 825 RPM, 208-230V), 81G48
$692.99 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of 3/4hp 208-230v Prog Blower motor, 87W50
$969.96 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of Blower Motor 1/2 HP ECM, 95W07
Blower Motor 1/2 HP ECM, 95W07
SKU: 95W07
Lennox
SKU: 95W07
Brand: Lennox
$962.57 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Compare
Product Image of X-13 Prog Motor Cons Torque, 97W54
X-13 Prog Motor Cons Torque, 97W54
SKU: 97W54
Lennox
SKU: 97W54
Brand: Lennox
$784.05 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of 208-230v 1/3hp Ecm Motor, 99W60
208-230v 1/3hp Ecm Motor, 99W60
SKU: 99W60
Lennox
SKU: 99W60
Brand: Lennox
$1,132.15 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Resources
FAQs, Manuals & Videos
Articles
More About Lennox Draft Blowers and Motors

Lennox Draft Blowers and Motors are replacement parts that pull combustion gases out of a furnace's heat exchanger and push them safely out through the flue or vent pipe, creating the negative pressure a gas furnace needs to fire correctly. A typical draft inducer in this category, such as the 42250-001, runs on a 1/30 HP motor at 208 to 230 volts, drawing 0.6 amps at 3000 RPM. Other models step up to 1/10 HP on a permanent split capacitor design suited to higher-voltage 460 volt applications. Technicians replace this part when a furnace fails to fire, produces a pressure switch fault code, or the original blower wheel becomes noisy or unbalanced after years of run time. Matching the exact part number to the furnace model matters more with draft inducers than with most furnace parts, since HP, voltage, and RPM vary significantly across the Lennox furnace lineup, and an incorrect motor can trip the pressure switch even when it physically bolts into place.

Subcategories

  • 115 Volt Draft Inducer Motors: Draft inducers built for 115 volt single-phase power, such as the 65204100 assembly, commonly run at 1/25 HP and 3000 RPM. Residential Lennox furnaces on standard household circuits make up the majority of applications using this voltage. Installers confirm voltage compatibility before ordering, since a 115 volt motor won't run correctly on a furnace wired for 208-230 volts. Catalog number 20J89 cross-references this assembly for Lennox parts counters and distributors.
  • 208-230 Volt Draft Inducer Motors: Motors rated for 208 to 230 volts, like the 42250-001, typically run at 1/30 HP, 3000 RPM, and draw around 0.6 amps. Many mid-size residential and light commercial Lennox furnace models rely on this voltage range for their draft inducer motor. Catalog number 74K77 identifies this assembly at Lennox parts counters. Confirming the amp draw and RPM against the furnace's original part label prevents ordering a motor that runs at the wrong speed for the venting system.
  • 460 Volt PSC Draft Inducer Motors: Higher-voltage 460 volt models, such as the 69M32, use a permanent split capacitor design running at 3200 RPM and 1/10 HP. Light commercial and larger residential furnace installs on three-phase or higher-voltage service call for this motor type instead of a standard 115 or 230 volt unit. PSC motors of this type require a run capacitor sized to the motor, so replacing the motor without also checking capacitor compatibility can leave the draft inducer underpowered. Getting the voltage right up front avoids installing a motor that won't reach the RPM needed to trip the furnace's pressure switch.

Buying Guide

Start with the voltage stamped on the furnace's original motor or listed in the unit's wiring diagram, since Lennox draft inducers span 115 volt, 208-230 volt, and 460 volt configurations that aren't interchangeable. A 115 volt motor won't run on a 230 volt circuit, and a 460 volt PSC motor needs three-phase or higher-voltage service that most single-family homes don't have. Horsepower and RPM matter just as much as voltage. A furnace's original part carries a specific HP and RPM rating, commonly 1/30 HP at 3000 RPM or 1/10 HP at 3200 RPM depending on the model, and a mismatched RPM can leave the draft inducer unable to generate enough negative pressure to satisfy the furnace's pressure switch, which shows up as a fault code and a furnace that won't fire. Amperage draw is worth checking too, since a motor pulling more current than the furnace's control board or wiring is rated for can trip a breaker or damage the board over time. Lennox Draft Blowers and Motors are typically ordered by catalog number rather than by generic specs, so pulling the number off the furnace's failed motor or its rating plate is the fastest way to confirm an exact match. When the original catalog number isn't visible or the label has worn off, cross-referencing HP, voltage, amp draw, and RPM together narrows the search to the correct replacement without guessing.

Frequently Asked Questions

How is the correct voltage draft inducer identified for a Lennox furnace?

Voltage is stamped on the furnace's original motor or listed on the unit's wiring diagram, and Lennox draft inducers span 115 volt, 208-230 volt, and 460 volt configurations. Matching that voltage exactly matters, since a 115 volt motor won't operate correctly on a 230 volt circuit.

What happens if the wrong RPM motor gets installed?

A mismatched RPM can leave the draft inducer unable to generate enough negative pressure to satisfy the furnace's pressure switch. The furnace typically responds with a fault code and won't fire, even though the replacement motor physically bolts into place.

What's the best way to find the exact replacement part?

Pulling the catalog number directly off the failed motor or the furnace's rating plate is the fastest way to confirm an exact match. When the label has worn off, cross-referencing HP, voltage, amp draw, and RPM together narrows the search to the correct replacement.

Can a 115 volt motor be swapped for a 230 volt one on the same furnace?

No, voltage needs to match the furnace's original wiring and control board rating. Installing the wrong voltage motor can trip a breaker, damage the control board, or leave the motor unable to reach the RPM the furnace needs to satisfy its pressure switch.

Why does a furnace need a draft inducer at all?

A draft inducer pulls combustion gases out of the heat exchanger and pushes them out through the flue or vent pipe, creating the negative pressure a gas furnace needs to fire safely. Without it, combustion gases could linger in the heat exchanger instead of venting properly.

Didn't find what you're looking for? 
Let us know
.