Sloan UPPERCUT Exposed Water Closet Flushometers are manual, dual-flush valves designed for commercial restrooms that need both a full flush and a reduced-volume option from the same handle. The WES-111 model delivers a 1.6 gallon-per-flush full flush or a 1.1 gallon-per-flush reduced flush depending on handle position, connecting to the fixture through a 1.5 inch top spud. A green, ADA-compliant handle with an antimicrobial coating identifies the water-saving feature and withstands the heavy cycle counts typical of commercial restrooms. Facility managers and plumbing contractors specify UPPERCUT valves on renovation projects where exposed, wall-mounted flushometers are already in place and code requires dual-flush water savings. The valve body meets ASSE 1037 performance requirements and uses semi-red brass construction rated under ASTM alloy classifications, giving it the durability commercial restrooms demand across high-traffic public and institutional buildings.
Subcategories
Buying Guide
Start with rough-in dimension, since that measurement determines fitment before any other spec matters. Standard commercial restrooms typically use an 11.5 inch rough-in, matching the WES-111, while accessible stalls or fixtures set further from the wall need the 24 inch rough-in of the WES-115. Sloan UPPERCUT Exposed Water Closet Flushometers all share the same 1.6 gallon-per-flush full flush and 1.1 gallon-per-flush reduced flush operation, so the rough-in and spud connection are typically what differentiate one model from another rather than flush performance. Spud size is the next check: confirm the 1.5 inch top spud connection matches the water closet's existing fitting, since a mismatch requires an adapter or fixture change. Water supply pressure and pipe size feeding the flushometer need to meet the manufacturer's minimum flow requirements, particularly on older buildings where galvanized supply lines may restrict flow below what a flushometer needs to perform both flush volumes correctly. ADA compliance is required in accessible stalls, so confirming the green, non-hold-open handle meets local code requirements for operating force and reach matters on any public restroom renovation. Facility managers replacing older single-flush exposed valves with a dual-flush model should also verify the wall plate and handle placement work within the existing stall layout before ordering, since dual-flush handles operate with two distinct positions rather than a single push action.
Frequently Asked Questions
What's the difference between the WES-111 and WES-115 models?
The WES-111 fits an 11.5 inch rough-in, the standard spacing found in most existing commercial restrooms, while the WES-115 fits a 24 inch rough-in used in accessible stalls or fixtures set further from the wall. Both models deliver the same 1.6 gallon-per-flush full flush and 1.1 gallon-per-flush reduced flush performance from a single handle. Choosing between them comes down to matching the existing or specified rough-in dimension rather than a difference in flush performance.
How does the dual-flush handle work on an UPPERCUT flushometer?
The UPPERCUT handle offers two distinct positions from the same green handle, one delivering a 1.6 gallon-per-flush full flush and the other a 1.1 gallon-per-flush reduced flush. The green color and handle position identify the water-saving feature for building occupants and maintenance staff. Metal wall plates included with the valve display operating instructions so occupants know how to select each flush option.
Is the Sloan UPPERCUT flushometer ADA compliant?
The UPPERCUT flushometer uses a non-hold-open handle design that meets ADA operational requirements for public restroom fixtures. Its handle also carries an antimicrobial coating intended to last over the valve's service life in high-traffic commercial restrooms. Facility managers should still confirm local code requirements for mounting height and operating force during installation, since ADA compliance depends on the complete installation, not the valve alone.
What causes an UPPERCUT flushometer to run continuously or flush weakly?
A worn or fouled diaphragm is the most common cause of a running or weak-flushing exposed flushometer, since the PERMEX Synthetic Rubber Diaphragm with Dual Filtered Fixed Bypass regulates both flush volumes. Mineral buildup in the bypass or a cracked diaphragm prevents the valve from sealing correctly after a flush cycle. Replacing the diaphragm assembly with the manufacturer's repair kit typically restores correct operation without replacing the entire valve body.
What materials and standards does the Sloan UPPERCUT valve body meet?
The UPPERCUT valve body, cover, tailpiece, and control stop use semi-red brass construction that complies with ASTM alloy classifications for that material. The valve also meets ASSE 1037 performance requirements, the standard governing pressurized flushing devices for water closets. Meeting both standards supports the valve's use in high-cycle commercial and institutional restroom applications.