Taco 570 Zone Valves are 24 volt heat motor zone valves built for hydronic heating systems that need reliable, independent temperature control across multiple zones. Each valve carries a maximum working pressure of 125 PSI and handles fluid temperatures up to 240°F, so it holds up in baseboard, radiant floor, and cast iron radiator loops alike. The 570 series spans models 570 through 573 and uses sweat connections ranging from half inch to one and a quarter inch, matching common residential and light commercial piping runs without added fittings. A removable, twist off powerhead lets a technician replace the electric actuator without cutting into the line or draining the whole system, cutting repair time on a callback. For contractors managing multi zone hydronic systems, a dependable zone valve determines whether a heating call gets solved in one visit or turns into a return trip. Reliability like that is why the 570 remains a standard spec on multi zone hydronic heating jobs across the trade.
Subcategories
Buying Guide
Sizing comes first when selecting a zone valve for a hydronic retrofit or new installation. Measure the existing sweat connection on the supply line, since Taco's 570 series spans half inch, three quarter inch, one inch, and one and a quarter inch ports, and an oversized or undersized valve throws off flow balance across the rest of the system. Pressure and temperature limits matter next: every valve in the line holds 125 PSI and 240°F, which covers standard residential boiler loops, but a commercial system running hotter water needs a different rated component entirely. Taco 570 Zone Valves share a twist off powerhead across the sizing range, so a technician stocking one replacement actuator can service several zones on a truck rather than carrying a separate part number for each valve body. Wiring counts too: the 570 series uses a 3 wire terminal block connection, which needs to match the zone control panel already on the job, whether that panel is an existing Taco panel or a mixed brand system. Voltage draw stays low at 24 volts with 0.9 amps per valve, so a transformer sized for the existing zone count typically covers a straight swap without an upgrade. On new construction, plan valve placement for easy powerhead access, since a valve buried behind finished ceiling or wall material turns a five minute swap into a demolition project. Matching size, pressure rating, and powerhead compatibility to the existing system keeps a zone valve replacement a same day fix.
Frequently Asked Questions
What's the pressure rating on a Taco 570 zone valve?
A Taco 570 zone valve holds a maximum working pressure of 125 PSI, which covers standard hydronic heating loops in residential and light commercial systems. Fluid temperature can reach up to 240°F, matching typical boiler supply temperatures. Both ratings apply across every sweat connection size offered in the 570 series.
Can the powerhead be replaced without swapping the whole valve?
The 570 series uses a twist off, removable powerhead, so a failed actuator comes off the valve body without cutting the line or draining the zone. A technician swaps the powerhead alone and gets the zone back online in minutes. The 555-050RP replacement powerhead covers models 570 through 573 across the full sweat size range.
What sweat connection sizes does the 570 come in?
Taco 570 Zone Valves ship in half inch, three quarter inch, one inch, and one and a quarter inch sweat connections. Matching the valve size to the existing pipe size keeps flow balanced across all zones on a manifold. An undersized valve on a larger pipe run restricts flow to that zone.
How much voltage does a 570 zone valve draw?
Each 570 series valve runs on 24 volts and draws 0.9 amps during operation. Transformer sizing on a job adding several new zones needs to account for the combined draw of every valve on the circuit. Undersized transformers cause valves to open sluggishly or fail to seat fully closed.
What applications is the 570 zone valve built for?
The 570 is built for hydronic heating applications, including baseboard, radiant floor, and cast iron radiator zones. Its 125 PSI and 240°F rating suits standard residential and light commercial boiler systems. Multi zone systems commonly use one 570 valve per zone, wired back to a central zone control panel.