Uponor Zone Valves & Controls are the components that direct hot water to individual loops on residential and light commercial radiant heating and hydronic systems. The lineup includes thermal zone valves and multi-zone control modules that pair with Uponor's TruFLOW manifolds to open and close flow to each zone on demand. A 1 inch thermal zone valve in this category carries a maximum working pressure of 125 psi and a maximum water temperature of 239°F, with a Cv of 7.0, numbers installers reference when sizing a manifold for a multi-zone home. Control modules add fuse protection, an isolated end switch, and a domestic hot water priority switch so a call for hot water takes precedence over space heating. Radiant and hydronic installers rely on this combination of valves and modules because it lets one boiler or heat source serve several independently controlled zones without a separate zone pump for every loop. Getting the valve and control pairing right keeps a heating system responsive and easy to service over time.
Subcategories
Buying Guide
Sizing a zone control setup starts with counting the zones a system needs to serve. Small radiant jobs with two or three zones typically pair one thermal zone valve per zone with a compact control module, while houses with four to six zones need a module rated for the matching fuse size, 3 amp for four-zone boards and 7 amp for six-zone boards. Pipe size matters too: the 3/4 inch and 1 inch sweat connections on Uponor's thermal zone valves need to match the manifold and branch piping already run on the job, and the 125 psi and 239°F ratings on the 1 inch valve should cover almost any residential hydronic loop. Uponor Zone Valves & Controls work as a matched system, so mixing an actuator from one product line with a control board from another can create wiring or voltage mismatches technicians have to troubleshoot later. Anyone retrofitting an existing manifold should confirm whether it's a TruFLOW Classic or TruFLOW Jr. before ordering thermal actuators, since the mounting differs between manifold families. Domestic hot water priority is worth checking on any control module going into a combi system, since that feature decides whether a shower takes precedence over a heating zone during simultaneous demand. Reviewing the fuse rating, connection size, and DHW priority feature together before ordering cuts down on return trips for the wrong part.
Frequently Asked Questions
What's the difference between a thermal zone valve and a zone control module?
A thermal zone valve is the mechanical valve that opens and closes flow to one heating zone, while a zone control module is the electrical board that coordinates thermostats, valves, and the pump or boiler relay across multiple zones. Most multi-zone hydronic systems need both working together. The valve handles the physical flow and the module handles the switching logic.
How many zones can one control module handle?
Uponor's control modules come in versions built for three, four, and six zones, with the fuse rating changing to match: a 3 amp delay fuse on four-zone boards and a 7 amp delay fuse on six-zone boards. Picking the right board size upfront avoids adding a second module later. Larger installations can link multiple boards for additional zones.
What size connections do the thermal zone valves use?
The thermal zone valves in this lineup use 3/4 inch and 1 inch sweat connections, sized to match TruFLOW manifold outlets on residential and light commercial radiant systems. The 1 inch valve carries a Cv of 7.0, a maximum working pressure of 125 psi, and a maximum water temperature of 239°F. Confirming the manifold's outlet size before ordering keeps the valve and manifold compatible.
Do thermal actuators work with any manifold?
Thermal actuators in this category mount only to TruFLOW Classic and TruFLOW Jr. valved manifolds, so the manifold family needs to be confirmed before ordering. Each actuator uses slow-opening, two-wire, 24 volt operation to control one loop on a multi-zoned manifold. Mixing actuator types across manifold families isn't supported.
What does the domestic hot water priority switch do?
The domestic hot water priority switch built into Uponor's zone control modules lets a call for hot water temporarily override calls for space heating. That keeps a shower or tap from running cold water while a heating zone is drawing from the same boiler. The priority timing is built into the module and doesn't need separate field wiring beyond the standard thermostat and valve connections.