Watts N36 water service vacuum relief valves protect water heaters, hot water supply tanks, and similar equipment from vacuum-related damage by automatically admitting air into the piping when a vacuum condition develops. The all-brass valve threads into the system with an NPT male inlet connection and carries a maximum working pressure of 200 psi, with a maximum steam rating of 15 psi for low-pressure steam applications. Its low-profile design and protective cap keep it out of the way in tight mechanical rooms, and the valve is tested and rated to ANSI Z21.22 with CSA certification. A vacuum condition without relief can siphon water out of a tank or heater fast enough to damage internal components, so the N36 is standard equipment on domestic water heaters, supply tanks, tabletop heaters, jacketed steam kettles, unit heaters, and steam coil heaters where that risk exists. Installing one on any tank-type appliance where backflow or rapid drainage could create negative pressure heads off a preventable equipment failure.
Subcategories
Buying Guide
Connection size is the first decision on any N36 order, since the valve is available in 1/2 inch and 3/4 inch NPT male sizes and needs to match the tapped opening on the existing water heater, tank, or steam equipment rather than an assumption based on tank capacity. All sizes share the same all-brass body construction, low-profile design, and protective cap, so material and build quality don't factor into which size to choose. The Watts N36 Water Service Vacuum Relief Valve carries a 200 psi maximum working pressure rating for water service and a separate 15 psi maximum steam pressure rating, and confirming which rating actually applies to the connected equipment matters before assuming the valve is a match. Domestic water heaters, supply tanks, and tabletop heaters typically fall under the water service rating, while jacketed steam kettles, unit heaters, and steam coil heaters fall under the lower steam rating. The valve's job is strictly to admit air during a vacuum event, not to relieve excess pressure, so it works alongside rather than in place of a pressure or temperature relief valve on the same piece of equipment. ANSI Z21.22 testing and CSA certification back the valve for use on the water heating equipment where a vacuum relief valve is typically required by code or manufacturer instructions. Checking the existing connection size and confirming whether the application falls under the water or steam pressure limit covers the decisions that matter on an N36 order.
Frequently Asked Questions
What does the Watts N36 actually protect against?
It protects water heaters, supply tanks, and similar equipment from vacuum conditions that could siphon water out of the system and damage internal components. It works by automatically admitting air once a vacuum develops, rather than relieving pressure.
Is the N36 a substitute for a pressure or temperature relief valve?
No. It only addresses vacuum conditions and doesn't relieve excess pressure or temperature, so it's installed alongside, not instead of, a standard T&P relief valve on the same equipment.
What sizes does the N36 come in?
It's available in 1/2 inch and 3/4 inch NPT male connections. Matching the size to the tapped opening on the existing equipment is necessary since the two sizes aren't interchangeable without an adapter.
Can the N36 be used on steam equipment?
Yes, it's rated for low-pressure steam applications up to 15 psi, covering equipment like jacketed steam kettles, unit heaters, and steam coil heaters. That steam rating is lower than the valve's 200 psi water service rating, so confirming which rating applies to the equipment matters.
What certifications does the N36 carry?
It's tested and rated to ANSI Z21.22 and carries CSA certification, supporting its use on the water heating and steam equipment where a vacuum relief valve is commonly required.