Apply to be a TradeMaster!
Filter menu expanded

Filters

463,450 items
Reset

SORT

Wilo Top S Pump Parts

Help Face
Need a little help?
463450 items
Grid
List
Compare
Product Image of BWC036B100D1 Parts - Trane Heat Pumpnot-to-sell-product
BWC036B100D1 Parts - Trane Heat Pump
SKU: BWC036B100D1
Trane
SKU: BWC036B100D1
Brand: Trane
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of BWC075C700A2 Parts - Trane Heat Pumpnot-to-sell-product
BWC075C700A2 Parts - Trane Heat Pump
SKU: BWC075C700A2
Trane
SKU: BWC075C700A2
Brand: Trane
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of Form 7, C Body, 3/4" Trade, IMC, Rigid Iron Conduit Body, C27
$35.19 each
In Stock
Get 20 by Mon, Nov 30 - Tue, Dec 1
In Stock
Get 20 by Mon, Nov 30 - Tue, Dec 1
Compare
Product Image of Coil Sub - Assembly - Epoxy Coated, C29185EP
$993.85 each
In Stock
Get 4 by Fri, Nov 27
In Stock
Get 4 by Fri, Nov 27
Compare
Product Image of C2A330GKD200 Parts - Heil Quaker (ICP) Central Air Conditionernot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of C2A342GKB100 Parts - Heil Quaker (ICP) Central Air Conditionernot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of BWC090C406R3 Parts - Trane Heat Pumpnot-to-sell-product
BWC090C406R3 Parts - Trane Heat Pump
SKU: BWC090C406R3
Trane
SKU: BWC090C406R3
Brand: Trane
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of BWC090C4A0HC Parts - Trane Heat Pumpnot-to-sell-product
BWC090C4A0HC Parts - Trane Heat Pump
SKU: BWC090C4A0HC
Trane
SKU: BWC090C4A0HC
Brand: Trane
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of BWC090CD00E0 Parts - Trane Heat Pumpnot-to-sell-product
BWC090CD00E0 Parts - Trane Heat Pump
SKU: BWC090CD00E0
Trane
SKU: BWC090CD00E0
Brand: Trane
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of BWC090F4D0HC Parts - Trane Heat Pumpnot-to-sell-product
BWC090F4D0HC Parts - Trane Heat Pump
SKU: BWC090F4D0HC
Trane
SKU: BWC090F4D0HC
Brand: Trane
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of C48-3B Parts - Janitrol Air Conditionernot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of C4A324GKA200 Parts - Heil Quaker (ICP) Central Air Conditionernot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of C4A330GKA100 Parts - Heil Quaker (ICP) Central Air Conditionernot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of C4A418GKD200 Parts - Heil Quaker (ICP) Central Air Conditionernot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of C4A430GKD200 Parts - Heil Quaker (ICP) Central Air Conditionernot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of C30MPW0305 A Parts - Carrier Modular Water Cooled/Condenserless Liquid Chillernot-to-sell-product
Backorder
Get it by Wed, Feb 24 - Wed, May 19
Backorder
Get it by Wed, Feb 24 - Wed, May 19
Compare
Product Image of BWC090FC00F1 Parts - Trane Heat Pumpnot-to-sell-product
BWC090FC00F1 Parts - Trane Heat Pump
SKU: BWC090FC00F1
Trane
SKU: BWC090FC00F1
Brand: Trane
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of BWC120D200A3 Parts - Trane Heat Pumpnot-to-sell-product
BWC120D200A3 Parts - Trane Heat Pump
SKU: BWC120D200A3
Trane
SKU: BWC120D200A3
Brand: Trane
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of BWC120F300F1 Parts - Trane Heat Pumpnot-to-sell-product
BWC120F300F1 Parts - Trane Heat Pump
SKU: BWC120F300F1
Trane
SKU: BWC120F300F1
Brand: Trane
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of BWC120F3D0HC Parts - Trane Heat Pumpnot-to-sell-product
BWC120F3D0HC Parts - Trane Heat Pump
SKU: BWC120F3D0HC
Trane
SKU: BWC120F3D0HC
Brand: Trane
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of BW3AAN000112AAAA Parts - 80% AFUE 112000 Btuh Gas-Fired Hot Water Boilernot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of BW9AAN000100ABAA Parts - 90% AFUE 100000 Btuh Gas-Fired Condensing Water Boilernot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of BWA075CD00MA Parts - Trane Heat Pumpnot-to-sell-product
BWA075CD00MA Parts - Trane Heat Pump
SKU: BWA075CD00MA
Trane
SKU: BWA075CD00MA
Brand: Trane
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of C4A442GKA200 Parts - Heil Quaker (ICP) Central Air Conditionernot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of C4A448GKB100 Parts - Heil Quaker (ICP) Central Air Conditionernot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of C4A624GKD200 Parts - Heil Quaker (ICP) Central Air Conditionernot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of C4A648GKD100 Parts - Heil Quaker (ICP) Central Air Conditionernot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of Tychem 5000 C3128T Coverall w/ Respirator Fit Hood, Elastic Wrists, Socks w/ Outer Boot Flaps, Storm Flap; Adhesive Closure, Tan, 4X-Large (Pack of 6)
$658.78 each
In Stock
Get 2 by Mon, Nov 30 - Tue, Dec 1
In Stock
Get 2 by Mon, Nov 30 - Tue, Dec 1
Compare
Product Image of Tychem 5000 C3184T Coverall w/ Collar, Attached Dual Layer Gloves, Socks w/ Outer Boot Flaps, Double Storm Flap; Hook and Loop, Tan, Medium (Pack of 6)
$1,099.31 each
In Stock
Get 1 by Mon, Nov 30 - Tue, Dec 1
In Stock
Get 1 by Mon, Nov 30 - Tue, Dec 1
Compare
Product Image of Eaton Freedom NEMA Pneumatic Timer, 1-30 Sec, 1NO/1NC, Top Mount
$749.12 each
In Stock
Get 1 by Mon, Nov 30
In Stock
Get 1 by Mon, Nov 30
Compare
Product Image of Eaton Freedom NEMA Pneumatic Timer, 10-180 Sec, 1NO/1NC, Top Mount
$788.27 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of BWA120C40PH0 Parts - Trane Heat Pumpnot-to-sell-product
BWA120C40PH0 Parts - Trane Heat Pump
SKU: BWA120C40PH0
Trane
SKU: BWA120C40PH0
Brand: Trane
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of BWA200C700H0 Parts - Trane Heat Pumpnot-to-sell-product
BWA200C700H0 Parts - Trane Heat Pump
SKU: BWA200C700H0
Trane
SKU: BWA200C700H0
Brand: Trane
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of BWA240C30PK1 Parts - Trane Heat Pumpnot-to-sell-product
BWA240C30PK1 Parts - Trane Heat Pump
SKU: BWA240C30PK1
Trane
SKU: BWA240C30PK1
Brand: Trane
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of C4H342GKA200 Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of C4H348GKD200 Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of C4H448GKD100 Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of Tychem 5000 C3360T Bib Overall, Open Ankles, Adjustable Straps w/ Buckle, Tan, 2X-Large (Pack of 6)
$277.51 each
In Stock
Get 1 by Mon, Nov 30 - Tue, Dec 1
In Stock
Get 1 by Mon, Nov 30 - Tue, Dec 1
Compare
Product Image of Valve & Seat For 15b5, C3484-5
$145.35 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of C34A004 Parts - Trane Central Air Conditionernot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of C34A012 Parts - Trane Central Air Conditionernot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of C34DL02 Parts - Trane Central Air Conditionernot-to-sell-product
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of 3" 3000# A105N Carbon Steel 90° Elbow NPT
3" 3000# A105N Carbon Steel 90° Elbow NPT
SKU: C3501-48
Merit Brass
SKU: C3501-48
Brand: Merit Brass
$131.13 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of 1-1/2" 3000# A105N Carbon Steel 45° Elbow NPT
$28.24 each
BOX UP & SAVE 8%
$388.95 box of 15
$25.93 each
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Backorder
Get it by Thu, Dec 24 - Wed, Jan 27
Compare
Product Image of BWB718A100A1 Parts - Trane Heat Pumpnot-to-sell-product
BWB718A100A1 Parts - Trane Heat Pump
SKU: BWB718A100A1
Trane
SKU: BWB718A100A1
Brand: Trane
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of BP090C00A4DAA1A Parts - York Heat Pumpnot-to-sell-product
BP090C00A4DAA1A Parts - York Heat Pump
SKU: BP090C00A4DAA1A
York
SKU: BP090C00A4DAA1A
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of BP090C00B2EAA1A Parts - York Heat Pumpnot-to-sell-product
BP090C00B2EAA1A Parts - York Heat Pump
SKU: BP090C00B2EAA1A
York
SKU: BP090C00B2EAA1A
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Compare
Product Image of BP090C00N2DAD2A Parts - York Heat Pumpnot-to-sell-product
BP090C00N2DAD2A Parts - York Heat Pump
SKU: BP090C00N2DAD2A
York
SKU: BP090C00N2DAD2A
Brand: York
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Backorder
Get it by Tue, Dec 29 - Mon, Feb 1
Resources
FAQs, Manuals & Videos
Articles
More About Wilo Top S Pump Parts

Wilo Top S pump parts keep the Wilo Top S line of hydronic circulator pumps running in residential and light commercial heating and cooling systems. Wilo Top S circulators move hot or chilled water through hydronic piping in boiler, radiant, and fan coil applications, and replacement parts extend the service life of pumps already installed in the field. Common parts include motor cartridges, seal kits, gaskets, and control modules that wear or fail well before the pump housing itself needs replacement. Technicians servicing a Wilo Top S pump typically diagnose whether the issue is electrical, mechanical, or related to a worn wet end before ordering parts. Stocking the right cartridge and seal combination for a given pump size shortens repair time on a callback. Sourcing genuine Wilo replacement parts helps maintain the pump's original flow and efficiency performance rather than settling for a full pump swap.

Subcategories

  • Motor Cartridges: Motor cartridges contain the wet-rotor motor assembly that drives the pump impeller. Technicians replace a cartridge when the motor windings fail or bearings wear out, since the cartridge can typically be swapped without removing the pump body from the piping. Matching cartridge voltage and pump size to the installed housing is essential for proper fit. Replacing the cartridge alone is usually faster and less disruptive than replacing the entire pump.
  • Seal and Gasket Kits: Seal and gasket kits address leaks at the pump housing and cartridge interface, a common failure point in circulators that run continuously through a heating season. Technicians inspect for mineral buildup or a hardened gasket before assuming the pump body itself is damaged. Replacing seals proactively during scheduled maintenance can prevent a leak from becoming a no-heat emergency call. Kits are sized to match specific Wilo Top S pump models.
  • Control Modules: Control modules on variable-speed Wilo Top S pumps manage speed settings and communicate operating status. A failed module often causes the pump to run at a fixed speed or stop responding to system demand. Technicians troubleshoot wiring and power supply before replacing a module outright. Choosing the correct module version for the pump's control type avoids compatibility issues.
  • Flanges and Mounting Hardware: Flanges and mounting hardware connect the Wilo Top S pump body to the system piping and support proper alignment. Worn or corroded flange gaskets are a frequent source of slow leaks around the pump connection points. Technicians replace flange hardware during a full pump service to prevent recurring leaks. Correct flange sizing keeps the pump properly aligned with existing piping runs.
  • Buying Guide

    Ordering the correct Wilo Top S pump parts starts with confirming the exact pump model and voltage printed on the unit's nameplate, since cartridges and control modules are not interchangeable across the full Top S lineup. Technicians should determine whether the pump uses a fixed-speed or variable-speed motor cartridge before ordering a replacement, since installing the wrong type can leave the system without proper speed control. When a pump is leaking, checking whether the failure is at the seal, the gasket, or a cracked housing helps determine whether a seal kit will resolve the issue or a full cartridge or pump replacement is needed. For control modules, confirming the communication protocol the building automation system expects prevents a mismatch between the new module and existing controls. Contractors stocking Wilo Top S pump parts for commercial service routes often keep cartridges and seal kits on hand for the pump sizes most common in their service area, since hydronic systems can fail without much warning during cold weather. Reviewing the pump's original installation documentation, when available, helps confirm the exact part numbers needed and reduces the chance of ordering an incompatible component. Replacing worn parts on a Wilo Top S pump promptly, rather than waiting for a full failure, typically costs less in labor than an emergency pump swap during peak heating season.

    Frequently Asked Questions

    Can a Wilo Top S motor cartridge be replaced without draining the whole system?

    Most Wilo Top S pumps allow the cartridge to be removed while isolating the pump with flange-mounted isolation valves, limiting water loss to the pump body itself. Systems without isolation valves will require draining before cartridge replacement. Checking for isolation valves ahead of the service call helps technicians plan the repair more efficiently.

    What typically causes a Wilo Top S pump to run noisy?

    Noise often points to air trapped in the system, a worn bearing inside the motor cartridge, or debris caught in the impeller. Bleeding air from the system is usually the first troubleshooting step before replacing any parts. Persistent grinding or humming after bleeding usually indicates a cartridge replacement is needed.

    How do I identify the correct replacement seal kit for a Wilo Top S pump?

    The pump's model number and size, found on the nameplate, determine the correct seal kit, since kits vary by pump body size. Technicians should record this information before removing the pump for service. Ordering by nameplate model number avoids fit issues with the wrong kit.

    Why would a variable-speed Wilo Top S pump stop responding to a building automation system?

    A failed or disconnected control module is a common cause, along with wiring faults at the communication terminals. Technicians should verify power and signal wiring before replacing the module. Confirming the module's communication protocol matches the automation system prevents recurring issues after replacement.

    Is it possible to upgrade a fixed-speed Wilo Top S pump to variable-speed using replacement parts?

    Fixed-speed and variable-speed Wilo Top S pumps use different motor cartridges and control architectures, so an upgrade generally requires a cartridge designed for variable-speed operation along with a compatible control module. Confirming the pump housing supports the variable-speed cartridge is an important step before ordering parts. Contractors should check manufacturer documentation to confirm compatibility before attempting the upgrade.