Apply to be a TradeMaster!
Filter menu expanded

Filters

471,129 items
Reset

SORT

Wilo Z-15 Pump Parts

Help Face
Need a little help?
471129 items
Grid
List
Compare
Product Image of 13' 11" x 1" x 0.035" 2/3 TPI Welded Band Saw Blade, 1772354
$106.42 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Door, 400, Push - in - 15 Pk, 1702623-015
Door, 400, Push - in - 15 Pk, 1702623-015
SKU: 1702623-015
Delfield
SKU: 1702623-015
Brand: Delfield
$1,840.00 each
In Stock
Get 10 by Wed, Dec 2
In Stock
Get 10 by Wed, Dec 2
Compare
Product Image of Mesh Bag for Biomedia
Mesh Bag for Biomedia
SKU: 170277
Little Giant
SKU: 170277
Brand: Little Giant
$37.21 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Intake, 6000, 1702815
Intake, 6000, 1702815
SKU: 1702815
Delfield
SKU: 1702815
Brand: Delfield
$290.00 each
In Stock
Get 2 by Wed, Dec 2
In Stock
Get 2 by Wed, Dec 2
Compare
Product Image of Pan, Catch, Abs, 120, 1703025
Pan, Catch, Abs, 120, 1703025
SKU: 1703025
Delfield
SKU: 1703025
Brand: Delfield
$206.00 each
In Stock
Get 4 by Wed, Dec 2
In Stock
Get 4 by Wed, Dec 2
Compare
Product Image of Insert Access Door, 1706191
Insert Access Door, 1706191
SKU: 1706191
Multiplex
SKU: 1706191
Brand: Multiplex
$47.29 each
In Stock
Get 10 by Wed, Dec 2
In Stock
Get 10 by Wed, Dec 2
Compare
Product Image of Jard 3 Pole Definite Purpose Contactor w/ Lugs (30A, 24V)
$48.02 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Jard 3 Pole Definite Purpose Contactor w/ Lugs (30A, 240V)
$45.09 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Refrigeration Leak Sensor Wire Harness (6 Ft)
$54.17 each
In Stock
Get 1 by Wed, Dec 2
In Stock
Get 1 by Wed, Dec 2
Compare
Product Image of Burner, UHCM-200 18l60, 176728300
Burner, UHCM-200 18l60, 176728300
SKU: 176728300
ADP
SKU: 176728300
Brand: ADP
$62.82 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Flue Adapter 2-3" FSA/FOA/UAH 30 and 45, 176735000
Flue Adapter 2-3" FSA/FOA/UAH 30 and 45, 176735000
SKU: 176735000
ADP
SKU: 176735000
Brand: ADP
$240.86 each
In Stock
Get 7 by Thu, Dec 3 - Fri, Dec 4
In Stock
Get 7 by Thu, Dec 3 - Fri, Dec 4
Compare
Product Image of 16' 10" x 0.042" 4/6 TPI Welded Band Saw Blade, 1772372
$150.86 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 17' x 0.042" 4/6 TPI Welded Band Saw Blade, 1772374
$150.86 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 18' 10" x 0.042" 3/4 TPI Welded Band Saw Blade, 1772378
$168.60 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 1-1/4" Bi-Metal Speed Slot Hole Saw, 1772491
$19.65 each
In Stock
Get 26 by Thu, Dec 3 - Fri, Dec 4
In Stock
Get 26 by Thu, Dec 3 - Fri, Dec 4
Compare
Product Image of Hl10 4 Way Louv Ws140/175, 177274
Hl10 4 Way Louv Ws140/175, 177274
SKU: 177274
Reznor
SKU: 177274
Brand: Reznor
$469.15 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 3-5/8" Bi-Metal Speed Slot Hole Saw, 1772949
$27.39 each
In Stock
Get 1 by Thu, Dec 3 - Fri, Dec 4
In Stock
Get 1 by Thu, Dec 3 - Fri, Dec 4
Compare
Product Image of LED 100W LED Temporary High Bay P3 Fixture
LED 100W LED Temporary High Bay P3 Fixture
SKU: 17100LEDP3
Southwire
SKU: 17100LEDP3
Brand: Southwire
$120.42 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Faceplate #5 Stainless Steel
Faceplate #5 Stainless Steel
SKU: 174003-071
Armstrong Pumps
SKU: 174003-071
$69.47 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Pressure Switch, 17400516000851
Pressure Switch, 17400516000851
SKU: 17400516000851
MRCOOL
SKU: 17400516000851
Brand: MRCOOL
$14.26 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Kit, Conv LP To Ng, 176794800
Kit, Conv LP To Ng, 176794800
SKU: 176794800
ADP
SKU: 176794800
Brand: ADP
$82.06 each
In Stock
Get 23 by Thu, Dec 3 - Fri, Dec 4
In Stock
Get 23 by Thu, Dec 3 - Fri, Dec 4
Compare
Product Image of Kit, Conv Ng To LP High Altitude, 176795500
Kit, Conv Ng To LP High Altitude, 176795500
SKU: 176795500
ADP
SKU: 176795500
Brand: ADP
$82.06 each
In Stock
Get 11 by Thu, Dec 3 - Fri, Dec 4
In Stock
Get 11 by Thu, Dec 3 - Fri, Dec 4
Compare
Product Image of 11' 9" x 1" x 0.035" 4/6 TPI Welded Band Saw Blade, 1772331
$82.80 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 16" x 25' F118 Insulated Flex Duct (Gray Jacket)
$209.52 each
In Stock
Get 7 by Wed, Dec 2
In Stock
Get 7 by Wed, Dec 2
Compare
Product Image of Main Control Board, 17122000010185
Main Control Board, 17122000010185
SKU: 17122000010185
Carrier
SKU: 17122000010185
Brand: Carrier
$59.39 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 11' 11" x 1" x 0.035" 4/6 TPI Welded Band Saw Blade, 1772332
$82.80 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 15' 8" x 0.05" 2/3 TPI Welded Band Saw Blade, 1772368
$181.68 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 72" G-6-Ss Non-Teflon Ground Probe
$69.03 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 1/4 HP e-90 Cast Iron Inline Pump (1-1/2", 1 PH, 115/208-230V), 179256LF
$2,743.36 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 12' 10" x 1" x 0.035" 5/8 TPI Welded Band Saw Blade, 1792732
$83.10 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 3 HP e-90 Cast Iron Inline Pump (3-1/2", 1 PH, 208-230V), 179278LF
$3,351.80 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 10' 10-1/2" x 1" x 0.035" 4/6 TPI Welded Band Saw Blade, 1792849
$70.30 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Main Control Board, 17122300A00462
Main Control Board, 17122300A00462
SKU: 17122300A00462
Carrier
SKU: 17122300A00462
Brand: Carrier
$224.98 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 1/2 Mr Valve M420R 20Mbh @3.8 Wc, 174815
$472.52 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of R3-2K2-31 NEM Mini-Top, Right, 1750112325
R3-2K2-31 NEM Mini-Top, Right, 1750112325
SKU: 1750112325
Hussmann
SKU: 1750112325
Brand: Hussmann
$291.87 each
In Stock
Get 2 by Wed, Dec 2
In Stock
Get 2 by Wed, Dec 2
Compare
Product Image of Valve Sol 300Psi 6.5 Watt 7Va 1, 178677
$704.22 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 11' 6" x 1" x 0.035" 4/6 TPI Welded Band Saw Blade, 1792864
$76.71 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 12' 6" x 1" x 0.035" 4/6 TPI Welded Band Saw Blade, 1792870
$83.09 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 1-1/2 HP e-90 Cast Iron Inline Pump (1-1/2", 3 PH, 208-230/460V), 179302LF
$3,459.52 each
In Stock
Get 1 by Thu, Dec 3 - Fri, Dec 4
In Stock
Get 1 by Thu, Dec 3 - Fri, Dec 4
Compare
Product Image of 3 HP e-90 Cast Iron Inline Pump (3", 3 PH, 208-230/460V), 179309LF
$3,824.70 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 15' 6" x 0.042" 4/6 TPI Welded Band Saw Blade, 1793100
$133.11 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Ga8 Mixing Box W/Top O/A, Horiz R/A, 171285
$3,814.14 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Door, Outer PDV,SKG, 17147-BOCK
Door, Outer PDV,SKG, 17147-BOCK
SKU: 17147-BOCK
Bock
SKU: 17147-BOCK
Brand: Bock
$56.85 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Temperature Control w/ Probe
$163.33 each
In Stock
Get 5 by Wed, Dec 2
In Stock
Get 5 by Wed, Dec 2
Compare
Product Image of Leak Detector Fitting, 17535
Leak Detector Fitting, 17535
SKU: 17535
Bock
SKU: 17535
Brand: Bock
$4.84 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Single-Pole, Commercial Grade, Decora Dual Rocker Combo Switch - Light Almond (120V)
$20.24 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 1/3 HP e-90 Cast Iron Inline Pump (1-1/2", 1 PH, 115/208-230V), 179257LF
1/3 HP e-90 Cast Iron Inline Pump (1-1/2", 1 PH, 115/208-230V), 179257LF
SKU: 179257LF
Bell & Gossett
SKU: 179257LF
$2,738.54 each
In Stock
Get 1 by Thu, Dec 3 - Fri, Dec 4
In Stock
Get 1 by Thu, Dec 3 - Fri, Dec 4
Compare
Product Image of 13' 6" x 1" x 0.035" 5/8 TPI Welded Band Saw Blade, 1792737
13' 6" x 1" x 0.035" 5/8 TPI Welded Band Saw Blade, 1792737
SKU: 1792737
Lenox
SKU: 1792737
Brand: Lenox
$89.49 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Resources
FAQs, Manuals & Videos
Articles
More About Wilo Z-15 Pump Parts

Wilo Z-15 pump parts are the replacement components contractors use to service and rebuild Z-15 wet-rotor circulator pumps found in residential and light commercial hydronic heating and hot water recirculation systems. The Z-15 is a single-speed, in-line circulator, and its most commonly replaced parts are the pump head, rotor and impeller assembly, and the mounting gaskets that seal the pump body to the piping flanges. Over years of continuous operation, mineral buildup and worn bearings inside the wet-rotor cartridge are the usual reasons a Z-15 needs a rebuild rather than a full replacement. Keeping gaskets, cartridges, and mounting hardware on hand lets a contractor return a system to service the same day instead of waiting on a full pump swap, which matters most on boiler systems where extended downtime affects a building's heat.

Subcategories

  • Pump Heads: Pump heads house the motor and electrical connections for the Z-15 circulator and bolt directly onto the wet-rotor cartridge below. Contractors replace a pump head when the motor windings fail or a bad capacitor stops the rotor from starting, rather than swapping the entire unit. Because the head separates from the wet end without draining the whole system in most installations, it's often the fastest single-part repair on a Z-15. Matching the voltage and speed rating to the original nameplate keeps the replacement head compatible with the existing wiring.
  • Rotor & Impeller Assemblies: The rotor and impeller assembly is the wet-rotor cartridge that spins inside the pump body to move water through the system. Mineral scale and sediment are the most common causes of a sluggish or seized rotor, especially in older cast iron hydronic loops. Replacing the assembly restores full flow without needing to replace the pump housing or motor head. A worn sleeve bearing inside the assembly is usually what causes the humming or grinding noise contractors hear before a Z-15 fails outright.
  • Mounting Gaskets & Flanges: Mounting gaskets seal the pump body against the flanges that connect it to the supply and return piping. A worn or improperly seated gasket is one of the most common sources of a slow weep leak at the pump union. Flanges themselves rarely need replacement unless they've been damaged during a prior installation or corroded from years of exposure to boiler water. Keeping the correct gasket size on hand avoids a return trip when a routine pump service uncovers a leak at the union.
  • Cartridge Seal Kits: Cartridge seal kits bundle the O-rings and shaft seals needed to reseal the wet-rotor cartridge after it's opened for cleaning or bearing replacement. Using a complete kit instead of individual seals reduces the chance of missing a small O-ring that causes a repeat callback. Seal kits are typically sized to the specific cartridge generation, so matching the kit to the pump's production era matters more than matching it to the overall Z-15 model name alone. A fresh seal kit is standard practice any time the cartridge is removed for service, even if the old seals look intact.
  • Buying Guide

    When sourcing Wilo Z-15 pump parts, start with the failure symptom rather than guessing at a full parts list. A pump that hums but doesn't spin usually points to a seized rotor or worn bearing, calling for a rotor and impeller assembly rather than a new pump head. A pump that won't start electrically, or trips a breaker, more often points to the motor windings or capacitor inside the pump head itself. Confirm the exact age and cartridge generation of the installed unit before ordering, since Wilo has updated the internal cartridge design over the years and parts from a newer cartridge don't always fit an older pump body. For jobs where the pump has been in continuous service for many years, rebuilding with a full cartridge seal kit alongside the rotor assembly is often more efficient than replacing components piecemeal, since it addresses wear across the whole wet end in one visit. Keep a small stock of the most commonly needed Wilo Z-15 pump parts, gaskets, seal kits, and a spare pump head, on hand for routine hydronic service calls, since these are the components most likely to fail from years of continuous operation. For a pump that's failed catastrophically or is several rebuilds in already, replacing the entire unit is often the more practical long-term choice over continuing to source individual parts.

    Frequently Asked Questions

    How do I know if my Wilo Z-15 needs a new pump head or a full rotor assembly?

    If the pump is silent and doesn't spin at all, check the motor head first, since that usually points to a failed capacitor or burned winding. If the pump hums or vibrates but the rotor won't turn, the wet-rotor cartridge itself is more likely the problem. Testing continuity at the motor terminals before ordering parts helps confirm which component actually failed.

    Can I rebuild a Z-15 without draining the whole heating system?

    In most installations, the pump head separates from the wet-rotor cartridge without opening the main piping, so a motor swap doesn't require draining the loop. Replacing the cartridge, gaskets, or flanges does require isolating and draining the pump section, though the rest of the system can often stay filled if isolation valves are present. Always confirm the specific installation has isolation valves before promising a no-drain repair.

    Why does my Z-15 keep leaking at the union even after a new gasket?

    A repeat leak after a gasket replacement is usually a sign the flange itself is corroded, warped, or wasn't torqued evenly during installation. Overtightening a new gasket can also distort it and cause the same leak to return. Checking the flange surface for pitting and torquing bolts in a cross pattern typically resolves a recurring union leak.

    How long does a Z-15 cartridge seal kit typically last?

    Seal life depends heavily on water quality and how often the system cycles, so there's no single fixed interval for every installation. Systems with harder water or more mineral content tend to wear seals faster than closed loops with treated water. Replacing the seal kit any time the cartridge is opened for service, rather than waiting for a visible leak, helps avoid a repeat callback.

    Is it worth rebuilding an older Z-15 or should I replace the whole pump?

    A rebuild makes sense when the pump body and flanges are still in good condition and only the wet-rotor cartridge or motor head has failed. Once a pump has needed several rebuilds over a short period, or the housing itself shows corrosion, replacing the entire unit is usually the more practical option. Weighing the age of the installation against the parts already on hand helps make that call quickly during a service visit.