Apply to be a TradeMaster!
Filter menu expanded

Filters

461,006 items
Reset

SORT

Wilo Z-15 Pump Parts

Help Face
Need a little help?
461006 items
Grid
List
Compare
Product Image of PY5GNAB24060NA-- Parts - Carrier Gas Heat/Electric Cool Packaged Unitnot-to-sell-product
Backorder
Get it by Mon, Feb 22 - Mon, May 17
Backorder
Get it by Mon, Feb 22 - Mon, May 17
Compare
Product Image of PY5GNAB42090NA-- Parts - Carrier Gas Heat/Electric Cool Packaged Unitnot-to-sell-product
Backorder
Get it by Mon, Feb 22 - Mon, May 17
Backorder
Get it by Mon, Feb 22 - Mon, May 17
Compare
Product Image of PYPA48ZA4 Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of Thermostat 24v 3h2c Cnvhp Prog, R62080
Thermostat 24v 3h2c Cnvhp Prog, R62080
SKU: R62080
AAON
SKU: R62080
Brand: AAON
$859.20 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Sealant Poly-u Self-leveling, R63630
Sealant Poly-u Self-leveling, R63630
SKU: R63630
AAON
SKU: R63630
Brand: AAON
$33.62 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Distributor 15233-04-30, R32650
Distributor 15233-04-30, R32650
SKU: R32650
AAON
SKU: R32650
Brand: AAON
$330.72 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Distrib 1113-10-3/16-5g W/ Lds, R33040
Distrib 1113-10-3/16-5g W/ Lds, R33040
SKU: R33040
AAON
SKU: R33040
Brand: AAON
$517.60 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Seg Htwhl Sen Erc-3623, R33080
Seg Htwhl Sen Erc-3623, R33080
SKU: R33080
AAON
SKU: R33080
Brand: AAON
$423.16 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Mtr 3 1.3/3/575v/1800-1200 Odp, R31680
Mtr 3 1.3/3/575v/1800-1200 Odp, R31680
SKU: R31680
AAON
SKU: R31680
Brand: AAON
$4,292.34 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 20" Galvanized Steel 3 Blade Fixed Hub Fan Blade, CCW (28° Pitch)
$68.18 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Drift Eliminator Cdx-80 18x71, R32100
Drift Eliminator Cdx-80 18x71, R32100
SKU: R32100
AAON
SKU: R32100
Brand: AAON
$423.17 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 24" Galvanized Steel 3 Blade Fixed Hub Fan Blade (19° Pitch)
$117.17 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 24" Aluminum 3 Blade Hubless Fan Blade (26° Pitch)
$67.13 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 1-Pole Plug-In Tandem (CAFCI) Circuit Breaker (120V, 15A) UL Type QTAN
$126.65 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Q1SA-048K Parts - Nordyne Heat Pumpnot-to-sell-product
Q1SA-048K Parts - Nordyne Heat Pump
SKU: Q1SA-048K
Nordyne
SKU: Q1SA-048K
Brand: Nordyne
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of Distributor 11-4-24, R63880
Distributor 11-4-24, R63880
SKU: R63880
AAON
SKU: R63880
Brand: AAON
$519.14 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of R63LSe2P Parts - V Series (Value Series) Non-Condensing Tankless Water Heater, Outdoor, LS Series (Propane)not-to-sell-product
Backorder
Get it by Mon, Feb 22 - Mon, May 17
Backorder
Get it by Mon, Feb 22 - Mon, May 17
Compare
Product Image of Burner 2' Direct Fired Np-1-le, R64590
Burner 2' Direct Fired Np-1-le, R64590
SKU: R64590
AAON
SKU: R64590
Brand: AAON
$3,271.43 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Power 360-500vac To 24vdc 55w, R34780
Power 360-500vac To 24vdc 55w, R34780
SKU: R34780
AAON
SKU: R34780
Brand: AAON
$945.80 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Expansion Valve, R35580
Expansion Valve, R35580
SKU: R35580
AAON
SKU: R35580
Brand: AAON
$423.23 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Blade Damper 15.00, R37270
Blade Damper 15.00, R37270
SKU: R37270
AAON
SKU: R37270
Brand: AAON
$171.85 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Heater Unit 5kw/480v/18a, R32520
Heater Unit 5kw/480v/18a, R32520
SKU: R32520
AAON
SKU: R32520
Brand: AAON
$3,063.79 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Heat Wheel Kit (shaft&bearing), R34310
Heat Wheel Kit (shaft&bearing), R34310
SKU: R34310
AAON
SKU: R34310
Brand: AAON
$1,396.27 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 3% Room Mounted Humidity Sensor, R34690
3% Room Mounted Humidity Sensor, R34690
SKU: R34690
AAON
SKU: R34690
Brand: AAON
$322.95 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Wheel Assembly Heat Tot Erc-500d, R35300
Wheel Assembly Heat Tot Erc-500d, R35300
SKU: R35300
AAON
SKU: R35300
Brand: AAON
$1,627.59 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Seg Htwhl Tot Erc-3622c 6ea., R65900
Seg Htwhl Tot Erc-3622c 6ea., R65900
SKU: R65900
AAON
SKU: R65900
Brand: AAON
$4,845.37 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Filter 20x20x12 Cart Mrv13 85%, R67660
Filter 20x20x12 Cart Mrv13 85%, R67660
SKU: R67660
AAON
SKU: R67660
Brand: AAON
$352.38 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Filter 20x20x4 Plt Mrv8 30%, R67690
Filter 20x20x4 Plt Mrv8 30%, R67690
SKU: R67690
AAON
SKU: R67690
Brand: AAON
$28.97 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Prop 42.25/3-6/35/ppg/6w/1.38, R68110
Prop 42.25/3-6/35/ppg/6w/1.38, R68110
SKU: R68110
AAON
SKU: R68110
Brand: AAON
$1,252.90 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Ballast 120/240/277 Vac, R68880
Ballast 120/240/277 Vac, R68880
SKU: R68880
AAON
SKU: R68880
Brand: AAON
$986.77 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Run Capacitor For Air Handler
Run Capacitor For Air Handler
SKU: R68DE0001
Comfort-Aire
SKU: R68DE0001
Brand: Comfort-Aire
$367.38 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of R4GA-036K072C Parts - Nordyne Packaged Unit/RTUnot-to-sell-product
R4GA-036K072C Parts - Nordyne Packaged Unit/RTU
SKU: R4GA-036K072C
Nordyne
SKU: R4GA-036K072C
Brand: Nordyne
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of Ringers R167 Impact & Puncture Resistant Gloves, Touchscreen Compatible, Hi-Vis Yellow/Red, 2XL
$36.29 each
In Stock
Get 69 by Wed, Nov 25 - Fri, Nov 27
In Stock
Get 69 by Wed, Nov 25 - Fri, Nov 27
Compare
Product Image of Duct Mount Humidity Sensor, R17330 (0-10vdc)
$1,655.16 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Motor 2/3/575v/1170 He Odp, R18830
Motor 2/3/575v/1170 He Odp, R18830
SKU: R18830
AAON
SKU: R18830
Brand: AAON
$2,027.00 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Ftg Vict Flange Adapter 5.00, R12080
Ftg Vict Flange Adapter 5.00, R12080
SKU: R12080
AAON
SKU: R12080
Brand: AAON
$514.14 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Rope Fiberglass .375 Hi-Temp, R12590
Rope Fiberglass .375 Hi-Temp, R12590
SKU: R12590
AAON
SKU: R12590
Brand: AAON
$14.17 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 3-8" WC Pink Spring for RV131 & 210J Regulators
$65.84 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of PY1PNB024060AAAA Parts - Payne Packaged Unit/RTUnot-to-sell-product
PY1PNB024060AAAA Parts - Payne Packaged Unit/RTU
SKU: PY1PNB024060AAAA
Payne
SKU: PY1PNB024060AAAA
Brand: Payne
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of R4GA-042K096C Parts - Nordyne Packaged Unit/RTUnot-to-sell-product
R4GA-042K096C Parts - Nordyne Packaged Unit/RTU
SKU: R4GA-042K096C
Nordyne
SKU: R4GA-042K096C
Brand: Nordyne
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of R4GC-048K096C Parts - Nordyne Packaged Unit/RTUnot-to-sell-product
R4GC-048K096C Parts - Nordyne Packaged Unit/RTU
SKU: R4GC-048K096C
Nordyne
SKU: R4GC-048K096C
Brand: Nordyne
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of R4GD-030K072C Parts - Nordyne Packaged Unit/RTUnot-to-sell-product
R4GD-030K072C Parts - Nordyne Packaged Unit/RTU
SKU: R4GD-030K072C
Nordyne
SKU: R4GD-030K072C
Brand: Nordyne
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of R4GD-060K096X Parts - Nordyne Packaged Unit/RTUnot-to-sell-product
R4GD-060K096X Parts - Nordyne Packaged Unit/RTU
SKU: R4GD-060K096X
Nordyne
SKU: R4GD-060K096X
Brand: Nordyne
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of R4GD-060K120C Parts - Nordyne Packaged Unit/RTUnot-to-sell-product
R4GD-060K120C Parts - Nordyne Packaged Unit/RTU
SKU: R4GD-060K120C
Nordyne
SKU: R4GD-060K120C
Brand: Nordyne
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Backorder
Get it by Wed, Dec 23 - Thu, Jan 28
Compare
Product Image of Coil Evap 40.0x 42.0 3r14f Fs, R1946E
Coil Evap 40.0x 42.0 3r14f Fs, R1946E
SKU: R1946E
AAON
SKU: R1946E
Brand: AAON
$3,547.34 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Filter 20x16x4 Plt Mrv11 65%, R19710
Filter 20x16x4 Plt Mrv11 65%, R19710
SKU: R19710
AAON
SKU: R19710
Brand: AAON
$187.78 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Sensor, Temperature Control (not Shown), R2006600
$330.93 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Screen Ra Safety 24 Door Rl, R14540
Screen Ra Safety 24 Door Rl, R14540
SKU: R14540
AAON
SKU: R14540
Brand: AAON
$0.08 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Resources
FAQs, Manuals & Videos
Articles
More About Wilo Z-15 Pump Parts

Wilo Z-15 pump parts are the replacement components contractors use to service and rebuild Z-15 wet-rotor circulator pumps found in residential and light commercial hydronic heating and hot water recirculation systems. The Z-15 is a single-speed, in-line circulator, and its most commonly replaced parts are the pump head, rotor and impeller assembly, and the mounting gaskets that seal the pump body to the piping flanges. Over years of continuous operation, mineral buildup and worn bearings inside the wet-rotor cartridge are the usual reasons a Z-15 needs a rebuild rather than a full replacement. Keeping gaskets, cartridges, and mounting hardware on hand lets a contractor return a system to service the same day instead of waiting on a full pump swap, which matters most on boiler systems where extended downtime affects a building's heat.

Subcategories

  • Pump Heads: Pump heads house the motor and electrical connections for the Z-15 circulator and bolt directly onto the wet-rotor cartridge below. Contractors replace a pump head when the motor windings fail or a bad capacitor stops the rotor from starting, rather than swapping the entire unit. Because the head separates from the wet end without draining the whole system in most installations, it's often the fastest single-part repair on a Z-15. Matching the voltage and speed rating to the original nameplate keeps the replacement head compatible with the existing wiring.
  • Rotor & Impeller Assemblies: The rotor and impeller assembly is the wet-rotor cartridge that spins inside the pump body to move water through the system. Mineral scale and sediment are the most common causes of a sluggish or seized rotor, especially in older cast iron hydronic loops. Replacing the assembly restores full flow without needing to replace the pump housing or motor head. A worn sleeve bearing inside the assembly is usually what causes the humming or grinding noise contractors hear before a Z-15 fails outright.
  • Mounting Gaskets & Flanges: Mounting gaskets seal the pump body against the flanges that connect it to the supply and return piping. A worn or improperly seated gasket is one of the most common sources of a slow weep leak at the pump union. Flanges themselves rarely need replacement unless they've been damaged during a prior installation or corroded from years of exposure to boiler water. Keeping the correct gasket size on hand avoids a return trip when a routine pump service uncovers a leak at the union.
  • Cartridge Seal Kits: Cartridge seal kits bundle the O-rings and shaft seals needed to reseal the wet-rotor cartridge after it's opened for cleaning or bearing replacement. Using a complete kit instead of individual seals reduces the chance of missing a small O-ring that causes a repeat callback. Seal kits are typically sized to the specific cartridge generation, so matching the kit to the pump's production era matters more than matching it to the overall Z-15 model name alone. A fresh seal kit is standard practice any time the cartridge is removed for service, even if the old seals look intact.
  • Buying Guide

    When sourcing Wilo Z-15 pump parts, start with the failure symptom rather than guessing at a full parts list. A pump that hums but doesn't spin usually points to a seized rotor or worn bearing, calling for a rotor and impeller assembly rather than a new pump head. A pump that won't start electrically, or trips a breaker, more often points to the motor windings or capacitor inside the pump head itself. Confirm the exact age and cartridge generation of the installed unit before ordering, since Wilo has updated the internal cartridge design over the years and parts from a newer cartridge don't always fit an older pump body. For jobs where the pump has been in continuous service for many years, rebuilding with a full cartridge seal kit alongside the rotor assembly is often more efficient than replacing components piecemeal, since it addresses wear across the whole wet end in one visit. Keep a small stock of the most commonly needed Wilo Z-15 pump parts, gaskets, seal kits, and a spare pump head, on hand for routine hydronic service calls, since these are the components most likely to fail from years of continuous operation. For a pump that's failed catastrophically or is several rebuilds in already, replacing the entire unit is often the more practical long-term choice over continuing to source individual parts.

    Frequently Asked Questions

    How do I know if my Wilo Z-15 needs a new pump head or a full rotor assembly?

    If the pump is silent and doesn't spin at all, check the motor head first, since that usually points to a failed capacitor or burned winding. If the pump hums or vibrates but the rotor won't turn, the wet-rotor cartridge itself is more likely the problem. Testing continuity at the motor terminals before ordering parts helps confirm which component actually failed.

    Can I rebuild a Z-15 without draining the whole heating system?

    In most installations, the pump head separates from the wet-rotor cartridge without opening the main piping, so a motor swap doesn't require draining the loop. Replacing the cartridge, gaskets, or flanges does require isolating and draining the pump section, though the rest of the system can often stay filled if isolation valves are present. Always confirm the specific installation has isolation valves before promising a no-drain repair.

    Why does my Z-15 keep leaking at the union even after a new gasket?

    A repeat leak after a gasket replacement is usually a sign the flange itself is corroded, warped, or wasn't torqued evenly during installation. Overtightening a new gasket can also distort it and cause the same leak to return. Checking the flange surface for pitting and torquing bolts in a cross pattern typically resolves a recurring union leak.

    How long does a Z-15 cartridge seal kit typically last?

    Seal life depends heavily on water quality and how often the system cycles, so there's no single fixed interval for every installation. Systems with harder water or more mineral content tend to wear seals faster than closed loops with treated water. Replacing the seal kit any time the cartridge is opened for service, rather than waiting for a visible leak, helps avoid a repeat callback.

    Is it worth rebuilding an older Z-15 or should I replace the whole pump?

    A rebuild makes sense when the pump body and flanges are still in good condition and only the wet-rotor cartridge or motor head has failed. Once a pump has needed several rebuilds over a short period, or the housing itself shows corrosion, replacing the entire unit is usually the more practical option. Weighing the age of the installation against the parts already on hand helps make that call quickly during a service visit.