Z-DENS Increasers & Reducers are Z-FLEX polypropylene fittings that change the diameter of a Z-DENS flue run for condensing appliances. The listings include increasers sized 2 inch to 3 inch, 3 inch to 4 inch, and 4 inch to 5 inch. The polypropylene is specially developed and fire retardant, and it is ULC S636 certified for flue temperatures to a maximum of 230 degrees F (110 degrees C). Z-DENS is certified for use with condensing oil and gas fired heating appliances and is suitable for negative and positive pressure appliances. Installers pick these fittings when a vent run needs to change pipe diameter. Matching the transition size and the certification to the appliance keeps the vent run within its rated limits and the install straightforward.
Subcategories
Buying Guide
Start with the diameters. The listings include 2 inch to 3 inch, 3 inch to 4 inch, and 4 inch to 5 inch increasers, so measure the existing flue pipe and the size the run needs next before choosing a part. Check the product name on each listing for the exact size pair, since a 3 inch to 4 inch increaser and a 4 inch to 5 inch increaser are different parts.
Next, match the fitting to the appliance. Z-DENS is certified for use with condensing oil and gas fired heating appliances, and the polypropylene carries ULC S636 certification for flue temperatures to a maximum of 230 degrees F (110 degrees C). The listings also describe Z-DENS as suitable for negative and positive pressure appliances. Confirm the appliance flue gas temperature falls within the rated limit before installing.
When comparing Z-DENS Increasers & Reducers with other venting transitions, check which brand and material the rest of the run uses. Z-FLEX makes the Z-DENS polypropylene fittings, and compatibility with other components should be confirmed against manufacturer instructions and local code before installing.
Finally, plan the order around the full run. Count every diameter change, note the appliance category, and confirm the rated temperature before the job starts. A missing transition size can stall a vent install, and checking the sizes early avoids that.
Frequently Asked Questions
What are Z-DENS Increasers & Reducers used for?
Z-DENS Increasers & Reducers change the diameter of a Z-DENS polypropylene flue run. The listings include increasers in 2 inch to 3 inch, 3 inch to 4 inch, and 4 inch to 5 inch sizes. Z-DENS is certified for use with condensing oil and gas fired heating appliances.
What temperature are Z-DENS increasers rated for?
The polypropylene in Z-DENS increasers is ULC S636 certified for flue temperatures to a maximum of 230 degrees F (110 degrees C). Always check the appliance flue gas temperature against the listing before installing.
Can Z-DENS increasers go on positive pressure appliances?
The Z-DENS listings describe the product as suitable for use with negative and positive pressure appliances. Confirm the appliance and venting requirements against the manufacturer instructions before installing Z-DENS Increasers & Reducers.
What material are Z-DENS increasers made of?
Z-DENS increasers are made of polypropylene. The listings describe it as specially developed and fire retardant. The material is ULC S636 certified for flue temperatures to a maximum of 230 degrees F (110 degrees C).
What sizes do Z-DENS increasers come in?
The Z-DENS Increasers & Reducers listings include 2 inch to 3 inch, 3 inch to 4 inch, and 4 inch to 5 inch polypropylene increasers. Each size pair is a separate product. Match the pair to the existing and required flue diameters.