Apply to be a TradeMaster!
Filter menu expanded

Filters

6 items
Reset

SORT

Product Availability
–

Show In Stock Only (5)

Flow At 5 FT Head
–

140 GPM (1)
180 GPM (6)

Voltage
–

200v (2)
208V (2)
230V (3)
380v (1)
460v (1)

Cord Length
–

20' (5)
40' (1)

Review Score
–

(1)
(1)

16S Series 1 HP Sewage Pumps

Help Face
Need a little help?
6 items
Grid
List
Compare
Product Image of 16S-CIM 1 HP, 160 GPM, 230V - Manual Submersible Sewage Ejector Pump, 20ft power cord
$1,235.51 each
In Stock
Get 1 by Mon, Nov 23 - Wed, Nov 25
In Stock
Get 1 by Mon, Nov 23 - Wed, Nov 25
Compare
Product Image of 16S-CIM 1 HP, 160 GPM, 200-208V - Manual Submersible Sewage Ejector Pump, 20ft power cord (6.1m)
$1,402.29 each
In Stock
Get 3 by Mon, Nov 23 - Wed, Nov 25
In Stock
Get 3 by Mon, Nov 23 - Wed, Nov 25
Compare
Product Image of 16S-CIM 1 HP, 160 GPM, 230V - Manual Submersible Sewage Ejector Pump, 40ft power cord
$1,309.00 each
In Stock
Get 2 by Mon, Nov 23 - Wed, Nov 25
In Stock
Get 2 by Mon, Nov 23 - Wed, Nov 25
Compare
Product Image of 16S-CIM 1 HP, 160 GPM, 230V - 3 Phase, Manual Submersible Sewage Pump, 20ft power cord (6.1m)
$1,285.97 each
In Stock
Get 2 by Mon, Nov 23 - Wed, Nov 25
In Stock
Get 2 by Mon, Nov 23 - Wed, Nov 25
Compare
Product Image of 16S-CIM 160 GPM (606 LPM), 460-380V - 3 Phase, Manual Submersible Sewage Ejector Pump, 20ft power cord (6.1m)
16S-CIM 160 GPM (606 LPM), 460-380V - 3 Phase, Manual Submersible Sewage Ejector Pump, 20ft power cord (6.1m)
SKU: 514730
Little Giant
SKU: 514730
Brand: Little Giant
$1,598.47 each
Backorder
Get it by Tue, Dec 22 - Wed, Jan 27
Backorder
Get it by Tue, Dec 22 - Wed, Jan 27
Compare
Product Image of 16S-CIM 1 HP, 160 GPM, 200-208 - 3 Phase, Manual Submersible Sewage Ejector Pump, 20ft power cord
16S-CIM 1 HP, 160 GPM, 200-208 - 3 Phase, Manual Submersible Sewage Ejector Pump, 20ft power cord
SKU: 514750
Little Giant
SKU: 514750
Brand: Little Giant
$1,459.49 each
In Stock
Get 2 by Mon, Nov 23 - Wed, Nov 25
In Stock
Get 2 by Mon, Nov 23 - Wed, Nov 25
Resources
FAQs, Manuals & Videos
Videos
Articles
More About 16S Series 1 HP Sewage Pumps

16S Series 1 HP Sewage Pumps are manual submersible pumps from Little Giant for effluent, sewage, wastewater, and dewatering work. Each pump runs a 1 hp oil-filled permanent split capacitor motor and a two-vane, epoxy-coated cast iron non-clog impeller that passes solids to 2 inches. Discharge is 3 inch FNPT, and the pump moves 160 gpm at 10 feet of head with a shutoff head of 35 feet. Motor options cover single-phase 200-208V and 230V as well as three-phase 200-208V and 380-460V, so crews can match the pump to the service already on site. Little Giant lists a maximum liquid temperature of 140°F and designs the pump for continuous duty. For contractors sizing ejector basins and commercial lift stations, the right 16S depends on voltage, phase, and head requirements, so confirming those before ordering saves a return trip to the job.

Subcategories

  • Single-Phase 230V Pumps: Single-phase 230V 16S pumps fit buildings without three-phase service, such as residential and light commercial ejector basins. Little Giant lists 230V as one of two single-phase voltage options for the series. The 1 hp motor moves 160 gpm at 10 feet of head with a 35 foot shutoff head. Discharge is 3 inch FNPT.
  • Single-Phase 200-208V Pumps: Single-phase 200-208V pumps serve commercial buildings fed at 208V rather than 230V. Matching the nameplate voltage matters because Little Giant lists separate single-phase ratings for the series. Little Giant lists 2 inch solids handling for the series, passed by a two-vane non-clog impeller. Discharge is 3 inch FNPT.
  • Three-Phase 200-208V Pumps: Three-phase 200-208V pumps suit commercial and industrial sites that run three-phase power. Little Giant lists 200-208V among the three-phase ratings for the series, with 50 to 60 Hz operation. Shutoff head is 35 feet and maximum liquid temperature is 140°F.
  • Three-Phase 380-460V Pumps: Three-phase 380-460V pumps serve sites with higher-voltage three-phase service. Little Giant lists this rating for 50 to 60 Hz operation, and model 514730 lists a 20 foot cord. The pump keeps the same 3 inch FNPT discharge and 160 gpm flow at 10 feet of head.

Buying Guide

Start with the power supply. Voltage and phase decide which pump fits, so read the nameplate or panel schedule before comparing anything else. Little Giant lists single-phase 200-208V and 230V for the 16S, plus three-phase 200-208V and 380-460V.

Next, check the duty point. For 16S Series 1 HP Sewage Pumps, the published figures are 160 gpm at 10 feet of head and a shutoff head of 35 feet. Add static lift and friction loss for the discharge run, then confirm the pump still delivers useful flow at that working head. A pump operating near shutoff moves very little water.

Then confirm the liquid and the solids. The 16S passes solids to 2 inches through a two-vane non-clog impeller, and Little Giant lists a maximum liquid temperature of 140°F. Hot discharge from process equipment can exceed that limit, so check the source before specifying the pump.

Check the controls and plumbing last. Little Giant lists manual switch activation for the series, so decide how level control will be handled before ordering. Discharge is 3 inch FNPT, so size the check valve, union, and piping to match. Material details also help separate options: the 16S uses an epoxy-coated cast iron impeller, a stainless steel spring in the mechanical seal, a secondary exclusion seal, and pump-out vanes that reduce seal and bearing wear.

Frequently Asked Questions

What size solids can 16S Series 1 HP Sewage Pumps handle?

16S Series 1 HP sewage pumps handle solids to 2 inches, according to Little Giant. The impeller is a two-vane, non-clog design made of epoxy-coated cast iron. Both specs apply to the series as listed by Little Giant.

What discharge size do 16S sewage pumps have?

16S Series 1 HP sewage pumps use a 3 inch FNPT discharge. Plan the check valve and discharge piping around that connection.

What voltages do 16S 1 HP sewage pumps come in?

16S Series 1 HP sewage pumps are listed in single-phase 200-208V and 230V and three-phase 200-208V and 380-460V. Confirm voltage and phase against the panel before choosing a model.

How much flow does a 1 HP 16S sewage pump move?

A 16S 1 HP sewage pump moves 160 gpm at 10 feet of head, with a shutoff head of 35 feet. Flow drops as head rises, so calculate the total head on the discharge run first.

What is the maximum liquid temperature for a 16S sewage pump?

Little Giant lists 140°F as the maximum liquid temperature for the 16S sewage pump. Check the source temperature before specifying a 16S 1 HP sewage pump on any line with hot discharge.