700 Series gas valves are Robertshaw's line of combination, snap-action, and universal gas valves used to control burner ignition and gas flow on commercial and residential gas-fired heating equipment. The lineup spans replacements for small 3/8 inch pipe connections up to high-capacity 1 inch pipe valves rated for up to 720,000 BTU. Combination models pair a manual gas cock, an automatic pilot safety valve, and a pressure regulator in one body, while snap-action models use a remote sensing bulb and capillary tube to open and close the valve as temperature changes. Uni-Kit versions ship factory set for natural gas and convert to propane with an included regulator kit, which cuts down on stocking separate natural gas and LP models. Technicians replacing an aging or discontinued gas valve on a furnace, water heater, or unit heater rely on the 700 Series to match original equipment capacity and mounting without redesigning the gas train.
Subcategories
Buying Guide
Identify the ignition and control type on the existing gas valve before ordering a replacement. Standing pilot furnaces and water heaters typically pair with combination or millivolt valves, while equipment with electronic ignition modules calls for a universal valve built for intermittent pilot operation. Confirm voltage next: combination valves come in 24 volt, and 120V or 240V line voltage versions, and installing the wrong one means the valve won't respond to the existing thermostat or ignition control signal. Check pipe size and BTU capacity against the appliance's rating plate, since the 700 Series spans replacements from small 3/8 inch pipe connections up to high-capacity 1 inch pipe valves rated for up to 720,000 BTU, and an undersized valve restricts gas flow to the burner. For snap-action and snap-throttle models, measure the existing capillary tube length and sensing bulb placement so the remote-sensing replacement reaches the same mounting point on the appliance. Confirm gas type last. Many Uni-Kit valves ship factory set at 3.5 inches water column for natural gas and convert to liquid propane with an included regulator kit, so a technician working on an LP appliance still needs to complete that conversion before startup rather than assuming a factory default. Matching ignition type, voltage, pipe size, and gas type before ordering keeps a gas valve swap to a single visit instead of a return trip for the correct part.
Frequently Asked Questions
What's the difference between a combination gas valve and a snap-action gas valve in the 700 Series?
A combination gas valve in the 700 Series pairs a manual gas cock, an automatic pilot safety valve, and often a pressure regulator inside one body, and it typically runs on 24 volt or line voltage electrical control. A snap-action gas valve instead opens and closes through a remote sensing bulb connected by a capillary tube, without needing an electrical thermostat signal. Appliances with a standing pilot and mechanical temperature control, like some fryers and water heaters, commonly use the snap-action style.
How much BTU capacity does a 700 Series gas valve handle?
700 Series gas valves span replacements from small 3/8 inch pipe connections up to high-capacity 1 inch pipe valves rated for up to 720,000 BTU. Matching the pipe size and BTU rating on the appliance's data plate to the replacement valve keeps gas flow at the correct volume for the burner. An undersized valve restricts flow and can cause ignition or performance problems.
Can a natural gas 700 Series valve be converted to propane?
Many Uni-Kit 700 Series valves ship factory set at 3.5 inches water column for natural gas and include a regulator kit for converting to liquid propane. Completing the conversion kit installation before startup on an LP appliance matches the valve's output pressure to the propane system's requirements. Skipping that step on an LP job leaves the valve set for the wrong gas type.
What's a universal gas valve used for in the 700 Series lineup?
A universal gas valve in the 700 Series is built for intermittent pilot ignition systems that light the pilot electronically at each call for heat. Technicians stock universal valves to cover several original-equipment part numbers with fewer parts on hand. Intermittent pilot operation also cuts standing gas use compared to a continuously burning pilot light.
Why would a technician choose a millivolt gas valve instead of a 24 volt model?
A millivolt gas valve runs on the small current a standing pilot's thermocouple or thermopile generates, so it keeps working during a power outage. A 24 volt model depends on household electricity and a functioning transformer to open the valve. Appliances like wall furnaces and some water heaters that need to operate without grid power commonly use the millivolt 700-500 series valve.