Apply to be a TradeMaster!
Main product image of K42 Twin-Flo III Kick Space Heater
Magnifying glass
Hover image to zoom

K42 Twin-Flo III Kick Space Heater

SKU:
K42
Rating:
(82)
Q&A:
(32)
K42 Twin-Flo III Kick Space Heater
Magnifying glass
Hover image to zoom
$271.44 each
In Stock
In Stock
Get 123 Tue, Jul 28
Order by today, receive Tuesday
Free Shipping This item ships free
Easy Returns No restocking fee for 90 days

Product Highlights

Product Highlight: Color
Black
Product Highlight: BTU Output
5240 Max BTUs
Product Highlight: Connection Size
1/2" Connection
Product Highlight: Height (Inches)
3-7/8" Height
Product Highlight: BTU
1480-5240
Product Highlight: Width (Inches)
12-1/4" Width

Description

Kickspace heaters are the space-saving alternative to hot water baseboard. Designed to fit inconspicuously under a cabinet, in the floor, on or in the wall, kickspace heaters are ideal for hard to heat areas such as foyers, kitchens, and bathrooms.

Hot water from the home's boiler is circulated through the kickspace unit and the fan gently blows heated air into the room. The homeowner simply selects the fan speed, then the unit turns on and off automatically according to heating demand.

Twin-Flo III + kickspace heaters are your ideal solution wherever space is limited:
  • Under Cabinets
  • In Kitchens, Baths, and Foyers
  • Under Stair Risers and Windows

Specs

Color:

Black

BTU Output:

5240

Connection Size:

1/2"

Type:

Hydronic

Kickspace Heaters

Height (Inches):

3-7/8"

Product Type:

Kickspace Heater

Application:

Hydronic Heating

BTU:

1480-5240

BTU (Min):

1480

BTU (Max):

5240

Width (Inches):

12-1/4"

Height:

3-7/8"

Flow Rate:

1-3GPM

Model:

K42

Depth (Inches):

12-3/4"

Water Connection:

1/2"

Contact

Help Face
CALL US
Question? Call or text 888-757-4774
+
Help Face

Questions?

Speak with a real person who will go out of the way to help!
Call or text 888-757-4774
MondayThursday
8am7:45pm
Friday
9am7:45pm
SaturdaySunday
9am5:45pm


You May Also Need

K84 Twin-Flo III Kick Space Heater
SKU: K84
Beacon Morris

6 Replacement Parts

Motor Fan Assembly for K42 Twin-Flo III
SKU: BMKR02020-001
Beacon Morris
Help Image
Need help finding a replacement part?
Fill out the part request form and someone will get back to you shortly.
PART REQUEST FORM

Product Reviews

4.71 out of 82 reviews
99% would recommend this product
4.71
out of 82 Reviews
99% would recommend this product
WRITE A REVIEW
5 star
77%
4 star
17%
3 star
6%
2 star
0%
1 star
0%
WRITE A REVIEW
Customer Images

Most Liked Positive Review

The Good & Bad

I bought the smallest of the 3 units. The Good: Does the trick. On Low speed is quiet. Needed foot room in bath Rm and it is out of the way just like it needs to be. The Bad: On high it is loud. When installing you must connect electric and close elec access panel before drilling holes and bolting down unit (this is not mentioned in instructions). I have PEX and needed to solder Pex adaptors (no biggy but thought I would mention it). I foam insulated my bathroom and installed a [slightly] heated floor. If I still had fiberglass insulation I probably would not be able to run it on low speed. In that case I would have bought one of the larger units so I could run it on low speed.
VS

Most Liked Negative Review

Quality Control

1. I have installed and used a Twin-Flo kick space heater previously. This particular one must have been somebody's first day on the job? The copper was all completely oxidized where it had been soldered, and the solder was all around the joint. It doesn't leak, but it surprised me bc it doesn't look as good as the first one I got. 2. The knockouts for electrical were not cut through enough to "knock out"; I had to basically drill it out, which meant removing the hardware from position a few times. Including the internal hardware. End of the world? No. Frustrating? Yes. Time-consuming. Yes. 3. It's weird to me that they create the connection tubes to be the same length, but neither extends to near the edge of the copper U. So in certain installation situations (using the wall cabinet, for example), I was left to figure out how to extend it so that my hydronic piping would bypass the U from the highest tube. IDK if there's a way around it because you have multiple install scenarios but... 4. I also encountered an aquastat that the heat shrink was loose on. Literally slid right off. 5. It also did not fire up when it go to temp. I had to reposition it multiple times, and it leaves me to wonder if it's really just a faulty aquastat, since all of the repositioning didn't really change the contact surface area... Or is it the wiring? Dunno... Or somehow related to the switch? Again... Dunno... It's working at the moment. 6. Running the electrical cable from the bottom of the Kick-Flow did not leave a great deal of space between where the cable entered and the components of the Kick-Flow motor. It seemed like the knockout hole itself should be lower in the housing to avoid some of that. But it was also pretty challenging to get the nut on the cable clamp as a result. Again, not sure anything can be done about that bc it's used in a variety of ways.
Showing 1-10 of 82 reviews

Quality Control

1. I have installed and used a Twin-Flo kick space heater previously. This particular one must have been somebody's first day on the job? The copper was all completely oxidized where it had been soldered, and the solder was all around the joint. It doesn't leak, but it surprised me bc it doesn't look as good as the first one I got. 2. The knockouts for electrical were not cut through enough to "knock out"; I had to basically drill it out, which meant removing the hardware from position a few times. Including the internal hardware. End of the world? No. Frustrating? Yes. Time-consuming. Yes. 3. It's weird to me that they create the connection tubes to be the same length, but neither extends to near the edge of the copper U. So in certain installation situations (using the wall cabinet, for example), I was left to figure out how to extend it so that my hydronic piping would bypass the U from the highest tube. IDK if there's a way around it because you have multiple install scenarios but... 4. I also encountered an aquastat that the heat shrink was loose on. Literally slid right off. 5. It also did not fire up when it go to temp. I had to reposition it multiple times, and it leaves me to wonder if it's really just a faulty aquastat, since all of the repositioning didn't really change the contact surface area... Or is it the wiring? Dunno... Or somehow related to the switch? Again... Dunno... It's working at the moment. 6. Running the electrical cable from the bottom of the Kick-Flow did not leave a great deal of space between where the cable entered and the components of the Kick-Flow motor. It seemed like the knockout hole itself should be lower in the housing to avoid some of that. But it was also pretty challenging to get the nut on the cable clamp as a result. Again, not sure anything can be done about that bc it's used in a variety of ways.
silatjunkie
Oshkosh, WI
10 days ago
Was this review helpful to you?

I would buy again

It a great product, my first one I ordered the motor was no good right out of the box. Emailed supply House stating the motor was bad and needed a new one. Supply House sent me a warranty replacement asap. Thank you Supply House for the promtness in this mater. Overall great experience. 👍
John
Albuquerque, Nm
7 months ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Kickin

As usual, ordering was painless and delivery is always spot on
Diesel
Nj
8 months ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Does what it's supposed to do

Put one of these in a bath remodel after taking out the old baseboard registers. Out of sight and heats a small bath
Frank Z
Medina ohio
1 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Great product and price.

Great change from baseboard heating.
mulvane2
Traverse City MI
2 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Good purchase..

nice compact little until for the added heat in the kitchen, attractive face plate, the installation kit made it a breeze to connect to the existing loop.
itsmicorp
worcester, MA
3 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Works great!

Quite quite in the low speed.
Magicmurray
Ct.
3 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Matched perfectly

The core of my heater had frozen. Replacement of the entire unit was easy and the one I received fit perfectly and is working well.
Gregg in Laramie
Laramie, Wyoming
3 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Does the job fits right

Product fit perfectly, more then efficient enough to do the job.
Steve
New Jersey
4 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Great Company to do Business With

Order process easy, sales rep helpful in determining proper product to fit my needs, delivery on time. Product (kick-space heater) not yet installed, but is as advertised.
GEORGE
Kennebunk, ME
4 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Product Q&A

32 Questions
32 Questions
ASK A QUESTION

Q: I have the K41A model and it appears that the blower stopped working. Is there a way I can have the motor replaced? If so who would be qualified to replace it? If I had to buy a new one I'm getting from older post that I'm suppose to replace it with the K42 model, is this still the case?

Asked by Empact 14 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Part BMKR02020-001 is the replacement motor for K42 models, but these do not work on K41 units.

Was this review helpful to you?
-

Its so easy to replace you could do it yourself.

Was this review helpful to you?
-

Check the aquastat first. That senses the temperature and turns the fan on when it reads 120 degrees going thru the heater. Any decent HVAC tech will be able to troubleshoot this for you. Good luck.

Was this review helpful to you?
-

Hello, I purchased a new K42 model with the wall enclosure which are still in the box. My addition design changed so it was not used. If you are interested I can offer it to you for a reasonable amount. It might be best to swap yours out. Let me know. Rob

Was this review helpful to you?

Q: Can I install this in the middle of a 3/4 inch zone with baseboard elements before and after (a room before and a room after) it? If so How???

Asked by john 14 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

You can. You may want to install diverter tees to make sure the unit gets enough flow.

Was this review helpful to you?
-

Yes you can. You will install the K42 in parallel with your feed. In other words, both the in and out will be connected to the feed without removing any of the pipe. Tap into the 3/4 feed and solder in (or pex in) 2 – 3/4” flow director T fittings with 1/2 going to the K42 Remember you are catching water into the unit and returning it in the direction of the flow This will allow some of the hot water to be diverted into the K42, through the unit and back into the feed while the rest of it travels to the next room. What you don’t want to do is send the entire flow of hot water into the heater.

Was this review helpful to you?
-

Generally, you want to install different types of heating devices on different zones, because they respond differently. Mine is installed in parallel with baseboard convectors and radiators. The convectors and radiators are individually controlled by automatic temperature control valves. I have not control valve on the kickspace heater, but my entire system is on an outdoor temperature reset which lowers the circulating water temperature as the outside air temperature rises. When the circulating water temperature is below 140, the kickspace heater fan does not come on.

Was this review helpful to you?
-

In order to do this you need venturi type fittings that will cause resistance in the main 3/4 line that will cause some of the fluid to flow into the heater through the tee with a half inch leg while the rest continues on down the line. The fluid flowing through the heater will rejoin the main 3/4 line after the heater through another tee. You should read more about venturi tees and their function with a web search.

Was this review helpful to you?
-

It could be connected as a branch with a diverted tee I believe. Sent from my iPhone

Was this review helpful to you?

Q: Do you need a tempering valve between this and a 3/4" system?

Asked by julia 14 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

You would not need a tempering valve unless you want the kick space heater to operate at a different temperature from the rest of the system.

Was this review helpful to you?
-

No, tempering valves are only required for devices requiring water temps. less than what your furnace is producing.  This device is designed to handle the max. water temps. of a typical baseboard hot water system- ~180-190 F.  You will likely require monoflow tees (at least 1) to successfully divert water flow to this device (assuming it is being placed within a series heating loop).

Was this review helpful to you?
-

No tempering valve required if connecting to a hot water boiler with base board convecters.

Was this review helpful to you?
-

Depends on your setup. You will need to limit water temp thru the pex and moderate heating when heating demand is satisfied. My kickspace heater fan comes on when the heating water temperature exceeds 140F. I let it run wild (no tempering valves). However, my system is on an outdoor air temperature reset which reduces circulating water temp as outside air gets warmer. In our mild climate, I usually circulate warm (80 -120F) water. Sent from my Verizon Wireless BlackBerry

Was this review helpful to you?
-

No, the hotter the water the more the heat output

Was this review helpful to you?
-

I usually just create a 1/2" branch diverting half the flow thru the heater using 3/4 x 1/2 x 1/2 monoflo tees

Was this review helpful to you?
-

I did not need one. Works great.

Was this review helpful to you?
-

No you can connect it directly to your system.

Was this review helpful to you?
- Travis

Hi, you had emailed me directly, but I had no way of responding as this thread didn't show up at the time. You need the monoflow T(s) to correctly divert some flow to the kickspace heater but not all flow. A standard T will not work as well because more flow will go to the path of least resistance which is likely not the kickspace heater. If you place the unit directly in the 3/4" loop series (without a T) it is highly likely your series flow will be too reduced potentially causing issues throughout the heating loop.

Was this review helpful to you?

Q: In an under floor mount situation, there appears to very little access to the control panel. Can the controls be remotely mounted for better access once the unit is installed?

Asked by Rob 14 years ago

Add your answer

* Required Field
- Another PexSupply Customer

Yes, the controls can be remotely located with the 98F Module.

Was this review helpful to you?
- Another PexSupply Customer

Yes, I have never done that, but it seems to be simply a matter of installing a DPDT switch in a wall box where it is accessible. Bob Sent from my iPad

Was this review helpful to you?
- Another PexSupply Customer

Rob - they make a floor kit for the twin flo models. the kit # is FKM-2R. If the floor joist are 16 on center or larger I reccomend this kit. It makes everything accessible.

Was this review helpful to you?
- Another PexSupply Customer

I have installed a number of these units and yes you can put the controls any where you want, just a bit of imagination. these are very simple to install. I hope this is helpful, R

Was this review helpful to you?
- Another PexSupply Customer

No, you cannot move the control, but honestly I have left the control on low and have not needed to change it once as it is connected thermostat regulated....will not go on unless the pipe is hot.

Was this review helpful to you?
- Another PexSupply Customer

I've never used the Twin-Flo in an under floor installation, only under cabinet or in wall.

Was this review helpful to you?
- Another PexSupply Customer

As far as I know, this unit isn't made to "control" via remote controls. The unit is hard wired and has a bi-metal switch that turns the fan on to blow warm air out from under the counter when it detects a temperature rise from hot water flowing through it due to the furnace coming on when the thermostat tells the furnace to come on. Once the furnace shuts down and the water flowing through the unit cools down, the bi-metal switch opens and the fan stops. In other words, the unit sits under the counter and does nothing until the furnace comes on. Once the furnace comes on and sends hot water though the baseboard heating system to heat the house, the hot water flowing through the unit trips the fan switch turning the fan on to blow warm air out to heat the room (kitchen) without baseboard heaters due to cabinets taking up wall space. I suppose one could bypass the bi-metal switch and wire the unit to be run manually from a switch located somewhere in the room, but I'm not sure why one would do that unless one wanted air circulation for the room while the furnace is off. It sits there out of sight and out of mind until it stops working and the room never warms up. I hope this helps.

Was this review helpful to you?
- Another PexSupply Customer

I don’t know why you would want to do this. I’m assuming either for maintenance or perhaps to access the speed switch. There is nothing I know of that would allow you to do this unless you are going to jury rig it yourself. With that said, I would not attempt to modify this unit. The only thing that can possibly fail on this unit is the fan and that can’t be relocated.

Was this review helpful to you?
- Another PexSupply Customer

The controls on this unit are very simple. 3 options: Low, High, and Off. I am sure that with some electrical know how you could wire a special wall mounted switch to control this, but the manufacturer does not make any recommendations to do so. However, in my experience with the unit there is actually very little need to utilize controls. The unit only turns on if you are running your heat. It cycles on and off as the aquastat attached to the pipe within the unit senses hot water cycling through the pipe. I would think exterior controls would be more of a pain than it's worth. My unit stays on low setting year round, as I find the high setting a little loud and a bit much for my small bathroom. No need to ever turn it to off because if the heat is off it won't run and if the heat is on I want my bathroom warm. If your concern is simply controlling that specific room's temperature I would look into adding a line voltage type room thermostat. This will override the switch and shut the fan off once a maximum temperature is reached.

Was this review helpful to you?
- Another PexSupply Customer

It is possible to move the switch of course with longer wires, but given that the unit is switched on and off by a thermoswitch that has to be placed on the inlet pipe to turn the fan on, I am not sure how much use one would get from a more conveniently placed switch. I found the thermoswitch set way to high (93 degrees) for use with a modern high efficiency modulating boiler that often do not heat the water up much beyond 90 degrees in milder temparateures. The thermo switch should be set at 70 or even lower for this unit to be optimally effective in my application.

Was this review helpful to you?

Q: if the unit can heat,can you also use it to cool with cool water or glycal running thru it?.

Asked by cable guy 14 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

This unit can only operate as a heater. The blower will not operate with the self-contained aquastat if water temperatures are below 140°F. The blower motor shuts off at 120° F and will not operate until water temperatures reach 140°F again.

Was this review helpful to you?
- Marc the plumber

No it can not

Was this review helpful to you?

Q: Would the K42 be the most suitable replacement for a model K41A? What is the difference?

Asked by Mike 14 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Yes, the K42 is the replacement for older K41 units. While the units use different parts, there are no functional or output differences.

Was this review helpful to you?

Q: Can I install this in the middle of a 3/4 inch zone with baseboard elements before and after (a room before and a room after) it?

Asked by Brandon 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Yes, this is a perfectly acceptable installation. If the kickspace heater is not in-line with the baseboards, you may need a diverter tee.

Was this review helpful to you?

Q: the btu range is 1480-5280. how do I choose a unit say for a btu of 3000?

Asked by silver 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

The precise BTU output depends on the water temperature and flow rate. See page 3 of the document below for more information. http://s3.pexsupply.com/manuals/1249544798107/Beacon-Morris-Kickspace-Product-Info.pdf

Was this review helpful to you?

Q: can i install that model on 3/4 line ?

Asked by DZ 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Yes, you can.

Was this review helpful to you?

Q: Are the blower motors interchangeable on the K41 and The K42 models?

Asked by MR.Niceguy 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

No, they are not.

Was this review helpful to you?
Free Shipping
On orders over $99
We offer flexible shipping and scheduling options, up-to-date delivery estimates, and free ground shipping on any order over $99 to make sure your order gets to you on-time, for less.
Shipping Policy
Easy Returns
Returning items is as simple as 1-2-3
Ordered the wrong product? Item damaged in transit? Our 3-step process makes returning products easy – even up to a year after purchase – with no restocking fees on returns made within 90 days.
Return Policy