Apply to be a TradeMaster!
Main product image of K42 Twin-Flo III Kick Space Heater
Magnifying glass
Hover image to zoom

K42 Twin-Flo III Kick Space Heater

SKU:
K42
Rating:
(82)
Q&A:
(32)
K42 Twin-Flo III Kick Space Heater
Magnifying glass
Hover image to zoom
$271.44 each
In Stock
In Stock
Get 123 Tue, Jul 28
Order by today, receive Tuesday
Free Shipping This item ships free
Easy Returns No restocking fee for 90 days

Product Highlights

Product Highlight: Color
Black
Product Highlight: BTU Output
5240 Max BTUs
Product Highlight: Connection Size
1/2" Connection
Product Highlight: Height (Inches)
3-7/8" Height
Product Highlight: BTU
1480-5240
Product Highlight: Width (Inches)
12-1/4" Width

Description

Kickspace heaters are the space-saving alternative to hot water baseboard. Designed to fit inconspicuously under a cabinet, in the floor, on or in the wall, kickspace heaters are ideal for hard to heat areas such as foyers, kitchens, and bathrooms.

Hot water from the home's boiler is circulated through the kickspace unit and the fan gently blows heated air into the room. The homeowner simply selects the fan speed, then the unit turns on and off automatically according to heating demand.

Twin-Flo III + kickspace heaters are your ideal solution wherever space is limited:
  • Under Cabinets
  • In Kitchens, Baths, and Foyers
  • Under Stair Risers and Windows

Specs

Color:

Black

BTU Output:

5240

Connection Size:

1/2"

Type:

Hydronic

Kickspace Heaters

Height (Inches):

3-7/8"

Product Type:

Kickspace Heater

Application:

Hydronic Heating

BTU:

1480-5240

BTU (Min):

1480

BTU (Max):

5240

Width (Inches):

12-1/4"

Height:

3-7/8"

Flow Rate:

1-3GPM

Model:

K42

Depth (Inches):

12-3/4"

Water Connection:

1/2"

Contact

Help Face
CALL US
Question? Call or text 888-757-4774
+
Help Face

Questions?

Speak with a real person who will go out of the way to help!
Call or text 888-757-4774
MondayThursday
8am7:45pm
Friday
9am7:45pm
SaturdaySunday
9am5:45pm


You May Also Need

K84 Twin-Flo III Kick Space Heater
SKU: K84
Beacon Morris

6 Replacement Parts

Motor Fan Assembly for K42 Twin-Flo III
SKU: BMKR02020-001
Beacon Morris
Help Image
Need help finding a replacement part?
Fill out the part request form and someone will get back to you shortly.
PART REQUEST FORM

Product Reviews

4.71 out of 82 reviews
99% would recommend this product
4.71
out of 82 Reviews
99% would recommend this product
WRITE A REVIEW
5 star
77%
4 star
17%
3 star
6%
2 star
0%
1 star
0%
WRITE A REVIEW
Customer Images

Most Liked Positive Review

The Good & Bad

I bought the smallest of the 3 units. The Good: Does the trick. On Low speed is quiet. Needed foot room in bath Rm and it is out of the way just like it needs to be. The Bad: On high it is loud. When installing you must connect electric and close elec access panel before drilling holes and bolting down unit (this is not mentioned in instructions). I have PEX and needed to solder Pex adaptors (no biggy but thought I would mention it). I foam insulated my bathroom and installed a [slightly] heated floor. If I still had fiberglass insulation I probably would not be able to run it on low speed. In that case I would have bought one of the larger units so I could run it on low speed.
VS

Most Liked Negative Review

Quality Control

1. I have installed and used a Twin-Flo kick space heater previously. This particular one must have been somebody's first day on the job? The copper was all completely oxidized where it had been soldered, and the solder was all around the joint. It doesn't leak, but it surprised me bc it doesn't look as good as the first one I got. 2. The knockouts for electrical were not cut through enough to "knock out"; I had to basically drill it out, which meant removing the hardware from position a few times. Including the internal hardware. End of the world? No. Frustrating? Yes. Time-consuming. Yes. 3. It's weird to me that they create the connection tubes to be the same length, but neither extends to near the edge of the copper U. So in certain installation situations (using the wall cabinet, for example), I was left to figure out how to extend it so that my hydronic piping would bypass the U from the highest tube. IDK if there's a way around it because you have multiple install scenarios but... 4. I also encountered an aquastat that the heat shrink was loose on. Literally slid right off. 5. It also did not fire up when it go to temp. I had to reposition it multiple times, and it leaves me to wonder if it's really just a faulty aquastat, since all of the repositioning didn't really change the contact surface area... Or is it the wiring? Dunno... Or somehow related to the switch? Again... Dunno... It's working at the moment. 6. Running the electrical cable from the bottom of the Kick-Flow did not leave a great deal of space between where the cable entered and the components of the Kick-Flow motor. It seemed like the knockout hole itself should be lower in the housing to avoid some of that. But it was also pretty challenging to get the nut on the cable clamp as a result. Again, not sure anything can be done about that bc it's used in a variety of ways.
Showing 1-10 of 82 reviews

Quality Control

1. I have installed and used a Twin-Flo kick space heater previously. This particular one must have been somebody's first day on the job? The copper was all completely oxidized where it had been soldered, and the solder was all around the joint. It doesn't leak, but it surprised me bc it doesn't look as good as the first one I got. 2. The knockouts for electrical were not cut through enough to "knock out"; I had to basically drill it out, which meant removing the hardware from position a few times. Including the internal hardware. End of the world? No. Frustrating? Yes. Time-consuming. Yes. 3. It's weird to me that they create the connection tubes to be the same length, but neither extends to near the edge of the copper U. So in certain installation situations (using the wall cabinet, for example), I was left to figure out how to extend it so that my hydronic piping would bypass the U from the highest tube. IDK if there's a way around it because you have multiple install scenarios but... 4. I also encountered an aquastat that the heat shrink was loose on. Literally slid right off. 5. It also did not fire up when it go to temp. I had to reposition it multiple times, and it leaves me to wonder if it's really just a faulty aquastat, since all of the repositioning didn't really change the contact surface area... Or is it the wiring? Dunno... Or somehow related to the switch? Again... Dunno... It's working at the moment. 6. Running the electrical cable from the bottom of the Kick-Flow did not leave a great deal of space between where the cable entered and the components of the Kick-Flow motor. It seemed like the knockout hole itself should be lower in the housing to avoid some of that. But it was also pretty challenging to get the nut on the cable clamp as a result. Again, not sure anything can be done about that bc it's used in a variety of ways.
silatjunkie
Oshkosh, WI
10 days ago
Was this review helpful to you?

I would buy again

It a great product, my first one I ordered the motor was no good right out of the box. Emailed supply House stating the motor was bad and needed a new one. Supply House sent me a warranty replacement asap. Thank you Supply House for the promtness in this mater. Overall great experience. 👍
John
Albuquerque, Nm
7 months ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Kickin

As usual, ordering was painless and delivery is always spot on
Diesel
Nj
8 months ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Does what it's supposed to do

Put one of these in a bath remodel after taking out the old baseboard registers. Out of sight and heats a small bath
Frank Z
Medina ohio
1 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Great product and price.

Great change from baseboard heating.
mulvane2
Traverse City MI
2 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Good purchase..

nice compact little until for the added heat in the kitchen, attractive face plate, the installation kit made it a breeze to connect to the existing loop.
itsmicorp
worcester, MA
3 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Works great!

Quite quite in the low speed.
Magicmurray
Ct.
3 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Matched perfectly

The core of my heater had frozen. Replacement of the entire unit was easy and the one I received fit perfectly and is working well.
Gregg in Laramie
Laramie, Wyoming
3 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Does the job fits right

Product fit perfectly, more then efficient enough to do the job.
Steve
New Jersey
4 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Great Company to do Business With

Order process easy, sales rep helpful in determining proper product to fit my needs, delivery on time. Product (kick-space heater) not yet installed, but is as advertised.
GEORGE
Kennebunk, ME
4 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Product Q&A

32 Questions
32 Questions
ASK A QUESTION

Q: Due to a kitchen remodel the cast iron radiator must go. Is the K84 an appropriate replacement. We have single zone hydronic system.

Asked by Ike 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

The K84 is a popular choice for kitchens. It fits under most counters. As long as it meets your BTU requirements, it would be an excellent choice.

Was this review helpful to you?

Q: is there a bleeder valve on this unit or do I need to install one on the pipes outside the unit

Asked by 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

There is not; you would need to install your own as you described.

Was this review helpful to you?

Q: Is it better to get too big of Watt than too small. If you have an over size heater does it just run less to keep the temp at what you set the thermostat to be?

Asked by hot water to go 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

If you would be cutting it close with a smaller unit, we recommend that you select a larger one. It will run less than the smaller heater would have to. There is no need, however, to install an oversized heater if you know a smaller unit will be sufficient.

Was this review helpful to you?

Q: how loud is the K 42 in soams

Asked by Roselle Ron 16 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

From one foot away, the decibel level is 55 on low and 62 on high.

Was this review helpful to you?
- ANN THE ENGIEER

YOU CAN HEAR IT SOUNDS LIKE A BLOWER VENT FROM LIKE A FORCED AIR FURNACE A DISTANT SOUND

Was this review helpful to you?
- Greg

I don't know what a soams is, but I can hardly here it running. Well pleased

Was this review helpful to you?

Q: why wont the fan blow out the heat

Asked by av 16 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

If the switch is on, you may want to check that the aquastat and motor are working properly. One or both of them may need to be replaced.

Was this review helpful to you?

Q: is there a difference between flow II and flow III

Asked by phil 16 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

The Flow II is not longer made and there are no replacement parts available. All units are now Flow III.

Was this review helpful to you?

Q: is there a switch to regulat the fan motor?

Asked by bb 16 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Yes, the unit has a low-off-high switch for the fan.

Was this review helpful to you?
- Gypsy George

Yes, there is a rocker switch for low speed, off and high speed

Was this review helpful to you?

Q: Is the heater core pipes running through the heater made of copper or are they made of some other metal such as aluminum

Asked by gypsygeopul 16 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

The piping is copper.

Was this review helpful to you?

Q: which air vent is recomended in a one pipe system up-feed

Asked by sean 16 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

We would recommend sku 0590712 by Watts.

Was this review helpful to you?

Q: Can you please provide rough-in instructions? Thanks, from Bob in South Jersey

Asked by Bob 16 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Please see this installation guide: http://s3.pexsupply.com/manuals/1249544798107/Beacon-Morris-Kickspace-Installation.pdf

Was this review helpful to you?
Free Shipping
On orders over $99
We offer flexible shipping and scheduling options, up-to-date delivery estimates, and free ground shipping on any order over $99 to make sure your order gets to you on-time, for less.
Shipping Policy
Easy Returns
Returning items is as simple as 1-2-3
Ordered the wrong product? Item damaged in transit? Our 3-step process makes returning products easy – even up to a year after purchase – with no restocking fees on returns made within 90 days.
Return Policy