ICP Heil Quaker parts cover replacement components for Heil and Quaker-branded HVAC equipment. The range runs from capacitors and control boards to fan parts and limit switches. The category groups parts by function to help technicians find the right component during a service call.
Limit switches in particular are safety devices that shut a furnace down before the heat exchanger overheats. Replacing a failed switch with the correct rated part matters for safe operation. Keeping common capacitors and control boards on a service truck reduces the number of return trips for routine failures.
Subcategories
Buying Guide
Identifying an ICP Heil Quaker part starts with the model and serial number tag on the equipment cabinet, not the part that looks similar in a catalog photo. Heil Quaker shares tooling with Arcoaire, Comfortmaker, KeepRite, and Tempstar. The nameplate data often cross references to a part number sold under more than one of those brand names. Pulling the exact number from the equipment or the failed part itself avoids ordering the wrong one.
Control boards carry the most model specific variation in this lineup, since ignition sequence, blower staging, and diagnostic codes differ across furnace generations even within the Heil Quaker family. Match the board's connector count, mounting hole pattern, and terminal labeling to the original. Assuming any board with the right general description will work can leave a board that powers up but won't run the furnace correctly.
Capacitors and motors are usually the fastest calls to close out. They're defined by a small set of electrical specs: microfarad rating and voltage for capacitors, horsepower, RPM, and rotation direction for motors. Keeping the common sizes for the equipment most active in a given service area on the truck turns a same day diagnosis into a same day repair.
Limit switches and other safety controls need to match trip temperature exactly. A switch set to trip too high defeats the purpose of the safety circuit. A switch set to trip too low causes nuisance shutdowns. Cross reference the stamped temperature rating on the failed switch against the replacement. Swapping in any switch that merely fits the mounting bracket puts the safety function at risk.
For parts that fall into the miscellaneous category, such as gaskets, harnesses, and brackets, physical fit matters as much as any electrical spec. Compare dimensions and connector types side by side with the failed part before ordering. This saves a second order when a part with the right function turns out to be the wrong size.
Frequently Asked Questions
Are ICP and Heil Quaker parts the same as Arcoaire, Comfortmaker, and Tempstar parts?
Often, yes. Heil Quaker shares tooling with Arcoaire, Comfortmaker, KeepRite, and Tempstar, so a part number is often sold under more than one of those brand names. Confirming the exact part number stamped on the failed component is more reliable than matching by brand name alone.
Why won't a furnace fire even after replacing the control board?
A furnace can still fail to fire after a board swap if the new board's connector layout or staging sequence doesn't match the original. A separate component such as the igniter, gas valve, or limit switch may also be faulty. Checking the full ignition sequence against the equipment's wiring diagram after any board replacement rules out a second failed part.
How do I tell if a capacitor has failed on a Heil Quaker blower motor?
A motor that hums without starting, starts slowly, or runs hot and shuts off on overload often points to a failed run or start capacitor. Measuring the capacitor's microfarad rating against the value stamped on its case confirms the failure before ordering a replacement.
What causes a Heil Quaker furnace to short cycle on heat?
A tripped limit switch is a common cause, usually from restricted airflow, a dirty filter, or a blower running at the wrong speed for the heat output. Replacing the limit switch only fixes the symptom if the underlying airflow restriction is corrected at the same time.
Can a universal blower motor replace an OEM Heil Quaker motor?
A universal motor can work as a replacement when its horsepower, RPM, rotation direction, and frame size match the original motor exactly. Mounting hardware also needs to line up with the original.
Subcategories
Buying Guide
Identifying an ICP Heil Quaker part starts with the model and serial number tag on the equipment cabinet, not the part that looks similar in a catalog photo. Heil Quaker shares tooling with Arcoaire, Comfortmaker, KeepRite, and Tempstar. The nameplate data often cross references to a part number sold under more than one of those brand names. Pulling the exact number from the equipment or the failed part itself avoids ordering the wrong one.
Control boards carry the most model specific variation in this lineup, since ignition sequence, blower staging, and diagnostic codes differ across furnace generations even within the Heil Quaker family. Match the board's connector count, mounting hole pattern, and terminal labeling to the original. Assuming any board with the right general description will work can leave a board that powers up but won't run the furnace correctly.
Capacitors and motors are usually the fastest calls to close out. They're defined by a small set of electrical specs: microfarad rating and voltage for capacitors, horsepower, RPM, and rotation direction for motors. Keeping the common sizes for the equipment most active in a given service area on the truck turns a same day diagnosis into a same day repair.
Limit switches and other safety controls need to match trip temperature exactly. A switch set to trip too high defeats the purpose of the safety circuit. A switch set to trip too low causes nuisance shutdowns. Cross reference the stamped temperature rating on the failed switch against the replacement. Swapping in any switch that merely fits the mounting bracket puts the safety function at risk.
For parts that fall into the miscellaneous category, such as gaskets, harnesses, and brackets, physical fit matters as much as any electrical spec. Compare dimensions and connector types side by side with the failed part before ordering. This saves a second order when a part with the right function turns out to be the wrong size.
Frequently Asked Questions
Are ICP and Heil Quaker parts the same as Arcoaire, Comfortmaker, and Tempstar parts?
Often, yes. Heil Quaker shares tooling with Arcoaire, Comfortmaker, KeepRite, and Tempstar, so a part number is often sold under more than one of those brand names. Confirming the exact part number stamped on the failed component is more reliable than matching by brand name alone.
Why won't a furnace fire even after replacing the control board?
A furnace can still fail to fire after a board swap if the new board's connector layout or staging sequence doesn't match the original. A separate component such as the igniter, gas valve, or limit switch may also be faulty. Checking the full ignition sequence against the equipment's wiring diagram after any board replacement rules out a second failed part.
How do I tell if a capacitor has failed on a Heil Quaker blower motor?
A motor that hums without starting, starts slowly, or runs hot and shuts off on overload often points to a failed run or start capacitor. Measuring the capacitor's microfarad rating against the value stamped on its case confirms the failure before ordering a replacement.
What causes a Heil Quaker furnace to short cycle on heat?
A tripped limit switch is a common cause, usually from restricted airflow, a dirty filter, or a blower running at the wrong speed for the heat output. Replacing the limit switch only fixes the symptom if the underlying airflow restriction is corrected at the same time.
Can a universal blower motor replace an OEM Heil Quaker motor?
A universal motor can work as a replacement when its horsepower, RPM, rotation direction, and frame size match the original motor exactly. Mounting hardware also needs to line up with the original.