Apply to be a TradeMaster!
Filter menu expanded

Filters

175 items
Reset

SORT

Product Availability

Show In Stock Only (113)

Horse Power

1/5 (4)
1/4 (4)
1/3 (15)
1/2 (22)
3/4 (17)
1 (3)

Voltage

115V (13)
120v (6)
120-240V (1)
120/240V (1)
208/230V (7)
208V (10)
220-240V (1)
230V (10)
240v (5)

Review Score

(34)
(7)

Price Range

$50 to $60 (1)
$60 to $70 (1)
$70 to $80 (1)
$90 to $100 (3)
$100 to $200 (15)
$200 to $300 (12)
$300 to $400 (15)
$400 to $500 (20)
$500 to $600 (33)
$600 to $700 (22)

Blower Motors

Help Face
Need a little help?
175 items
Grid
List
Compare
Product Image of 1/2 HP Blower Motor, M0009006R
1/2 HP Blower Motor, M0009006R
SKU: M0009006R
Nordyne
SKU: M0009006R
Brand: Nordyne
$557.30 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Variable Speed Blower, 904075
Variable Speed Blower, 904075
SKU: 904075
Nordyne
SKU: 904075
Brand: Nordyne
$1,060.35 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Motor, Blower, PSC, 3/4, 6p, 3s, Rev, 01-0172
$102.55 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Kit, Motor, Com, Tsc, A, 1/20, Cwle, G8sa100, 1028584
$710.58 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Module, Blower Motor, BO, 3/4, Mg1e090, 1027354R
$582.07 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 1/3 Hp Blower Assembly, 904681
1/3 Hp Blower Assembly, 904681
SKU: 904681
Nordyne
SKU: 904681
Brand: Nordyne
$1,068.68 each
In Stock
Get 3 by Wed, Aug 19
In Stock
Get 3 by Wed, Aug 19
Compare
Product Image of Motor, Ftv, 2.5t, 045, R8ge, M0009033R
Motor, Ftv, 2.5t, 045, R8ge, M0009033R
SKU: M0009033R
Nordyne
SKU: M0009033R
Brand: Nordyne
$478.09 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Blower Assembly, 904537
Blower Assembly, 904537
SKU: 904537
Nordyne
SKU: 904537
Brand: Nordyne
$1,040.59 each
In Stock
Get 2 by Wed, Aug 19
In Stock
Get 2 by Wed, Aug 19
Compare
Product Image of Motor, Blower, PSC, 1/4, 6p, 3s, Rev, 01-0169
$79.12 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Blower Assembly, 921098
Blower Assembly, 921098
SKU: 921098
Nordyne
SKU: 921098
Brand: Nordyne
$521.33 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Motor, Blower, Ftv, K, 1, Ccwle, 622688
$455.18 each
In Stock
Get 1 by Thu, Aug 20
In Stock
Get 1 by Thu, Aug 20
Compare
Product Image of Blower Assembly, M3 (4 Ton), 904109
$589.10 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Blower Motor, M0092620R
Blower Motor, M0092620R
SKU: M0092620R
Nordyne
SKU: M0092620R
Brand: Nordyne
$1,161.16 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Blower Assembly For G6 Units, 904200
$872.06 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of ECM Motor, M0009036R
ECM Motor, M0009036R
SKU: M0009036R
Nordyne
SKU: M0009036R
Brand: Nordyne
$505.63 each
In Stock
Get 4 by Wed, Aug 19
In Stock
Get 4 by Wed, Aug 19
Compare
Product Image of Motor, Programmable, G7sc, 072, B, 1027390R
$565.35 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Blower Motor (1/2 HP, R4 Reprogrammed), M0090903R
$581.76 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 1 HP Variable Speed Programmable Motor, M0092607R
$2,334.72 each
In Stock
Get 1 by Wed, Aug 19
In Stock
Get 1 by Wed, Aug 19
Compare
Product Image of 3/4 HP Programmable Blower Motor, M0009003R
3/4 HP Programmable Blower Motor, M0009003R
SKU: M0009003R
Nordyne
SKU: M0009003R
Brand: Nordyne
$650.64 each
In Stock
Get 1 by Wed, Aug 19
In Stock
Get 1 by Wed, Aug 19
Compare
Product Image of 1/2 HP ECM Programmed Motor, M0092611R
1/2 HP ECM Programmed Motor, M0092611R
SKU: M0092611R
Nordyne
SKU: M0092611R
Brand: Nordyne
$1,571.97 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Blower Motor (3/4 HP, R6 Prog), M0090924R
Blower Motor (3/4 HP, R6 Prog), M0090924R
SKU: M0090924R
Nordyne
SKU: M0090924R
Brand: Nordyne
$633.63 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Blower Assembly, W/ Motor & Wheel, 903074
$584.57 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Kit, Motor, Com, Tsc, A, 1/20, Cwle, G8sa070, 1028583
$710.58 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 4 Speed ECM Motor 1/2HP, 1075 RPM (115V), M0009032R
$478.72 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Motor, Fan, Psc, 1/2, 8p, 1s, Rev, 01-0168
$141.29 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 1/2 HP ECM Motor (1050 RPM, 208-230V), M0023911R
$1,529.69 each
In Stock
Get 1 by Wed, Aug 19
In Stock
Get 1 by Wed, Aug 19
Compare
Product Image of 3/4 HP Variable Speed Blower Motor, M0092606R
$1,626.53 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of X13 Motor P5RF (1/2 HP), M0090923R
X13 Motor P5RF (1/2 HP), M0090923R
SKU: M0090923R
Nordyne
SKU: M0090923R
Brand: Nordyne
$640.04 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Multi Speed Blower Assembly (Heating/Cooling), 911030
$546.70 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of ECM Motor, 622715
ECM Motor, 622715
SKU: 622715
Nordyne
SKU: 622715
Brand: Nordyne
$1,729.57 each
In Stock
Get 2 by Wed, Aug 19
In Stock
Get 2 by Wed, Aug 19
Compare
Product Image of Blower Assembly Replacement, 904878
$1,441.75 each
In Stock
Get 3 by Wed, Aug 19
In Stock
Get 3 by Wed, Aug 19
Resources
FAQs, Manuals & Videos
Articles
More About Blower Motors

Blower motors are the components that move air through a Nordyne-brand furnace, air handler, or packaged HVAC unit, pulling return air across the heat exchanger or evaporator coil and pushing conditioned air into the supply ductwork. Replacement blower motors for Nordyne equipment fall into two broad categories: permanent split capacitor (PSC) motors, which run at a small number of fixed speed taps, and electronically commutated motors (ECM), which vary speed continuously to match airflow demand and typically draw less electricity over a heating or cooling season. Matching horsepower, voltage, rotation, and shaft configuration to the original equipment is critical, since an undersized or mismatched motor can shorten compressor life or trip a limit switch. Stocking common PSC and ECM replacements alongside matched capacitors keeps furnace and air handler repairs moving without a special order.

Subcategories

  • PSC Blower Motors: Permanent split capacitor motors are the traditional replacement choice for older Nordyne furnaces and air handlers, running at one fixed speed per tap rather than ramping output up or down. Contractors favor PSC motors for straightforward swaps where the original equipment used a multi-speed shaded-pole or PSC design and a lower-cost repair is the priority. Correct rotation and horsepower still have to match the nameplate before installation.
  • ECM Blower Motors: Electronically commutated motors use a built-in module to vary speed continuously, adjusting output to hold steady airflow as filters load up or ductwork static pressure changes. Many newer Nordyne furnaces and air handlers were built around ECM platforms for quieter operation and lower standby electrical draw. Replacing an ECM motor typically means matching both the motor and its control module to the original part number.
  • Blower Motor Capacitors: Run capacitors store and release the electrical charge that keeps a PSC blower motor's auxiliary winding in phase, and a weak or failed capacitor is one of the most common reasons a blower motor won't start or runs hot. Replacing the capacitor alongside an aging motor is common practice, since a mismatched microfarad rating can shorten the life of a brand-new motor. Capacitors are sized by microfarad rating and voltage to match the motor being installed.
  • Blower Wheels & Mounting Hardware: Blower wheels, motor mounts, and set screws round out a blower motor replacement, since a worn or unbalanced wheel can cause vibration and premature bearing wear even on a new motor. Mounting brackets and shaft collars are specific to the furnace or air handler cabinet size, so matching the original equipment's mounting pattern avoids a field-fabricated bracket. Keeping wheel and hardware sets on hand alongside motors reduces a single repair into two truck rolls.

Buying Guide

Selecting a replacement blower motor starts with the equipment nameplate, not the failed part alone: horsepower, voltage, RPM, rotation direction, and shaft diameter all have to match the furnace or air handler the motor serves. A motor rated too small for the static pressure of the duct system will run hot and fail early, while an oversized motor can overwhelm a coil or heat exchanger sized for a specific airflow. For PSC motors, matching the number of speed taps to the original wiring keeps the low, medium, and high fan speeds working as the equipment control board expects. Blower Motors sold as ECM replacements need their control module matched to the motor as a set, since mixing modules across manufacturers or model families is rarely supported and can prevent the motor from starting at all. Rotation direction, clockwise or counterclockwise viewed from the shaft end, is a frequent point of confusion since a motor with the wrong rotation will run backward and starve the system of airflow even though it spins normally. Replacing the run capacitor at the same time as the motor is inexpensive insurance against a callback, particularly on furnaces that have been in service more than a few heating seasons. For jobs where the original part number is no longer available, cross-reference guides that match horsepower, voltage, rotation, and frame size are the safest way to find a compatible substitute without guessing.

Frequently Asked Questions

How do I know if a blower motor or the capacitor failed?

A blower motor that hums but doesn't spin, or that starts and then shuts off on thermal overload, often points to a bad run capacitor rather than the motor windings. Testing the capacitor's microfarad rating with a meter and comparing it to the nameplate value is the quickest way to rule it out before replacing the motor itself. If the capacitor tests within range and the motor still won't run, the motor is likely the failed component.

Can a PSC blower motor be replaced with an ECM motor?

Some universal ECM replacements are built to bolt into a PSC motor's mounting pattern and wire into its existing speed taps, but the control board still has to support the ECM's signal type. Checking the equipment manufacturer's approved parts list before substituting motor types avoids a control board that can't properly communicate with the new motor.

What causes a blower motor to run but move little air?

A dirty or unbalanced blower wheel, a slipping set screw, or a collapsed section of flexible duct can all cut airflow even when the motor itself is healthy. Checking the wheel for buildup and confirming it's still secured to the shaft is a quick first step before assuming the motor is undersized.

Does rotation direction matter when installing a replacement blower motor?

Rotation direction matters because a blower wheel is shaped to move air efficiently in one direction only, and a motor spinning the wrong way will still turn but move far less air. Rotation is specified on the motor nameplate as viewed from the shaft end, so confirming it before wiring saves a return trip.

How often should blower motor bearings be checked?

Older motors with grease fittings benefit from a check at the start of each heating and cooling season, since dry bearings are a common source of the grinding or squealing noise that precedes a full motor failure. Sealed, permanently lubricated motors don't need service but should still be inspected for excess play in the shaft during a seasonal tune-up.

Didn't find what you're looking for? 
Let us know
.