Apply to be a TradeMaster!
Filter menu expanded

Filters

17 items
Reset

SORT

Product Availability
–

Show In Stock Only (16)

Gallons Per Flush
–

0.125 (1)
0.5 (1)
1 (4)
1.5 (6)
1.6 (2)
3.5 (3)

Spud Size
–

3/4" (8)
1-1/4" (7)
1-1/2" (2)

Series
–

1150 (1)
180 (5)
181 (1)
186 (8)
188 (1)

Review Score
–

(3)
(1)

Price Range
–

$100 to $200 (10)
$200 to $300 (6)
$600 to $700 (1)

Sloan Royal Exposed Urinal Flushometers

Help Face
Need a little help?
17 items
Grid
List
Compare
Product Image of Royal 186-1 Exposed Manual Urinal Flushometer (1 GPF/3.8 LPF)
$191.75 each
In Stock
Get 8 by Mon, Nov 23
In Stock
Get 8 by Mon, Nov 23
Compare
Product Image of Royal 186 Exposed Manual Urinal Flushometer (1.5 GPF/5.7 LPF)
$191.75 each
In Stock
Get 8 by Mon, Nov 23
In Stock
Get 8 by Mon, Nov 23
Compare
Product Image of Royal 952 Exposed Hydraulic Water Closet Flushometer, Rough Brass (1.6 GPF/6.0 LPF)
$240.24 each
In Stock
Get 17 by Mon, Nov 23
In Stock
Get 17 by Mon, Nov 23
Compare
Product Image of Royal 186-0.5 Exposed Manual Urinal Flushometer (0.5 GPF/1.9 LPF)
$191.76 each
In Stock
Get 6 by Mon, Nov 23
In Stock
Get 6 by Mon, Nov 23
Compare
Product Image of Royal 180-1.5 Exposed Manual Urinal Flushometer (1.5 GPF/5.7 LPF)
$191.75 each
In Stock
Get 2 by Mon, Nov 23
In Stock
Get 2 by Mon, Nov 23
Compare
Product Image of Royal 180 Exposed Manual Urinal Flushometer (3.5 GPF/13.2 LPF)
$191.75 each
In Stock
Get 7 by Mon, Nov 23
In Stock
Get 7 by Mon, Nov 23
Compare
Product Image of Royal 186-0.125-DBP Exposed Manual Urinal Flushometer with Dual-Filtered Bypass (0.125 GPF/0.5 LPF)
$191.75 each
In Stock
Get 2 by Mon, Nov 23
In Stock
Get 2 by Mon, Nov 23
Compare
Product Image of Royal 180-1 Exposed Manual Urinal Flushometer (1.0 GPF/3.8 LPF)
$191.75 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of Royal Exposed Manual Single Flush Water Closet Bedpan Washer Flushometer (1.6 GPF/6.0 LPF)
$662.35 each
In Stock
Get 8 by Mon, Nov 23
In Stock
Get 8 by Mon, Nov 23
Compare
Product Image of Royal 186 U Exposed Manual Urinal Flushometer (1.5 GPF/5.7 LPF)
$223.44 each
In Stock
Get 3 by Mon, Nov 23
In Stock
Get 3 by Mon, Nov 23
Compare
Product Image of Royal 186-1H Exposed Manual Urinal Flushometer (1.0 GPF/3.8 LPF)
$242.87 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of Royal 186-1HL3 Exposed Manual Urinal Flushometer w/ 3" Metal Push Button (1.0 GPF/3.8 LPF)
$262.31 each
In Stock
Get 5 by Mon, Nov 23
In Stock
Get 5 by Mon, Nov 23
Compare
Product Image of Royal 186 H Exposed Manual Urinal Flushometer (1.5 GPF/5.7 LPF)
$242.87 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Compare
Product Image of Royal 188-1.5-XD Exposed Manual Urinal Flushometer w/ Adjustable Ground Joint Tailpiece (1.5 GPF/5.7 LPF)
$183.37 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of Royal 180 T Exposed Manual Urinal Flushometer (3.5 GPF/13.2 LPF)
$191.75 each
In Stock
Get 5 by Mon, Nov 23
In Stock
Get 5 by Mon, Nov 23
Compare
Product Image of Royal 180 H Exposed Manual Urinal Flushometer (3.5 GPF/13.2 LPF)
$242.87 each
In Stock
Get 3 by Tue, Nov 24
In Stock
Get 3 by Tue, Nov 24
Compare
Product Image of Royal 181-1.5 Exposed Manual Urinal Flushometer (1.5 GPF/5.7 LPF)
$195.16 each
In Stock
Get 2 by Mon, Nov 23
In Stock
Get 2 by Mon, Nov 23
Resources
FAQs, Manuals & Videos
Articles
More About Sloan Royal Exposed Urinal Flushometers

Sloan Royal exposed urinal flushometers mount on the surface of the wall rather than behind it, which is the main distinction from a concealed flushometer and the reason they are common in commercial and institutional restrooms where quick service access matters more than a fully hidden valve. An exposed design lets a technician service the diaphragm, handle, or vacuum breaker without opening the wall, which keeps a restroom back in service faster after a repair.

The valve itself is a diaphragm-type design, where water pressure and a rubber diaphragm control the flush cycle rather than a piston, and the diaphragm is the part most likely to need replacement over the life of the valve. High-traffic locations like schools, stadiums, and office buildings specify exposed flushometers specifically for that easier maintenance access.

Subcategories

  • Diaphragm Repair Kits: Diaphragm kits contain the rubber diaphragm and related seals that wear out from repeated flush cycles and are the most common service part ordered for this style of valve. Replacing a worn diaphragm typically resolves a flushometer that runs continuously or flushes weakly. Kits are matched to the specific flushometer model, since diaphragm dimensions vary across product generations.
  • Vacuum Breakers & Flush Tubes: The vacuum breaker prevents backflow of wastewater into the potable water supply and is a required component on every urinal flushometer installation. Flush tubes connect the valve body to the fixture's spud connection and can corrode or crack over years of service, particularly in humid restroom environments. Both parts are typically replaced as a set when either shows signs of mineral buildup or wear.
  • Handles & Trim: Handle assemblies are the most frequently touched component on a manual exposed flushometer and the most common source of a loose or leaking flush lever over time. Trim kits let a facility match the valve's finish to other restroom fixtures during a renovation without replacing the entire flush valve body. Confirming thread type and handle style compatibility with the existing valve body avoids an improper fit.
  • Buying Guide

    Confirm the fixture's rough-in and spud connection before ordering a replacement valve, since flushometer bodies are sized to match a specific urinal's inlet spud, and a mismatch will leak at the connection regardless of how well the valve itself performs.

    Sloan Royal Exposed Urinal Flushometers are built for manual, handle-operated actuation, which matters when a facility is deciding between manual and sensor-operated valves for a renovation. Manual valves have fewer components that can fail electronically but rely on users to activate the flush, which is a consideration for high-traffic public restrooms.

    Check available water pressure and flow rate at the fixture before selecting a flushometer, since these valves need a minimum supply pressure to complete a full flush cycle reliably. A location with low incoming pressure may need a low-consumption or pressure-assisted model rather than a standard valve.

    Stock diaphragm repair kits alongside any new flushometer installation, since the diaphragm is the part most likely to need replacement first and having a kit on hand shortens the time a fixture is out of service. Confirming the exact model number on the valve body before ordering parts avoids a kit that does not fit.

    Frequently Asked Questions

    What does exposed mean on this type of flushometer?

    Exposed means the entire valve body mounts on the surface of the wall rather than being concealed behind it, which makes the diaphragm, handle, and vacuum breaker accessible for service without opening the wall.

    How do I know when the diaphragm needs to be replaced?

    A flushometer that runs continuously after a flush, flushes weakly, or drips at the handle is usually signaling a worn diaphragm. Replacing the diaphragm kit typically resolves these symptoms without needing to replace the entire valve.

    Is a vacuum breaker required on a urinal flushometer?

    Yes. The vacuum breaker prevents wastewater from being siphoned back into the potable water supply and is a required component on every installation, not an optional accessory.

    Can I convert a manual exposed flushometer to a sensor-operated model?

    Some manufacturers offer retrofit kits for this, but it typically requires replacing the handle assembly with a sensor module and confirming the valve body is compatible with that retrofit. Checking compatibility with the specific valve model before ordering a conversion kit is worth the extra step.

    What causes a flushometer to leak at the spud connection?

    A leak at the spud connection usually points to a worn gasket, a loose connection, or a mismatch between the valve body and the fixture's inlet spud size. Confirming the correct spud coupling and gasket for the specific urinal model resolves most connection leaks.

Didn't find what you're looking for? 
Let us know
.