VB6 Series Valves and Actuators are Honeywell six-way characterized control ball valves paired with modulating actuators for heating and cooling coil control. The valves cover a Cv range of 0.3 to 14.0 on both control sequences, so installers can match the valve to the coil load. Bodies are nickel-plated brass with stainless steel balls and stems, and the design targets zero internal leakage. Typical jobs include chilled beam units, fan coil units, small air handling coils, bypass piping, and single heat exchangers in four-pipe systems. Honeywell offers the line in 1/2 inch and 3/4 inch sizes, with 80 possible configurations and a modular layout for two-pipe and four-pipe applications. Correct Cv selection matters because it sets how well the valve controls flow at partial load, and tight shutoff keeps a closed coil from wasting energy.
Subcategories
Buying Guide
Start with the coil's design flow and pressure drop, because Cv drives every other choice. VB6 valves span a Cv range of 0.3 to 14.0 on both control sequences, so calculate the Cv for each sequence separately and pick the closest configuration instead of defaulting to line size. Honeywell lists 80 possible configurations, which leaves room to size heating and cooling independently.
Confirm the piping layout next. The VB6 line supports modular configuration for two-pipe and four-pipe applications, and it is used for a single heat exchanger in a four-pipe system. Check the connection size against the coil, since Honeywell offers 1/2 inch and 3/4 inch sizes.
When comparing VB6 Series Valves and Actuators, confirm what each part number includes. Honeywell preassembles each valve with an MN7510 actuator, so match the model's Cv pairing to the job before ordering. Verify pressure and temperature limits against the system. Honeywell lists 600 psi through the rated temperature range, and the product data sheet carries the full ratings for each model.
Plan for commissioning as well. The actuator has a removable access cover for direct terminal block wiring and a declutch function for manual adjustment during installation. Finally, match the application. Honeywell lists chilled beam units, fan coil units, small air handling coils, and bypass piping as intended uses. For anything not on that list, verify with the SupplyHouse team or Honeywell before specifying.
Frequently Asked Questions
What Cv range do VB6 Series Valves and Actuators cover?
VB6 Series Valves and Actuators cover a Cv range of 0.3 to 14.0 for both control sequences, according to Honeywell. Honeywell lists 80 possible configurations, so heating and cooling Cv can be paired separately. Check the model number to confirm the exact pairing.
What sizes do VB6 valves come in?
Honeywell offers VB6 Series Valves and Actuators in 1/2 inch and 3/4 inch sizes. Valve bodies are nickel-plated brass with stainless steel balls and stems. Confirm the connection type on the individual model page before ordering.
Do VB6 valves come with an actuator?
Honeywell preassembles each VB6 six-way valve with an MN7510 actuator. The modulating actuator has a removable access cover for terminal block wiring. A declutch function allows manual adjustment during installation.
What applications are VB6 six-way valves used for?
VB6 six-way valves control water flow on chilled beam units, fan coil units, small air handling coils, and bypass piping. They also suit a single heat exchanger in a four-pipe system. Honeywell supports two-pipe and four-pipe configurations through its modular layout.
What pressure rating do VB6 valves carry?
Honeywell lists VB6 six-way valves at 600 psi through the rated temperature range. The product data sheet has the pressure and temperature limits for a specific model. Compare those limits to the system before specifying VB6 Series Valves and Actuators.