| Fuel Type: | Natural Gas |
|---|---|
| Inlet Size: | 1/2" |
| Outlet Size: | 3/4" |
| Capacity (BTU): | 230000 |
| Ignition Type: | Standing Pilot |
| Voltage: | 24V |
This valve is universal and can be configured to work for what you neeed it will work up to 100,000 BTU Heater
This is a universal replacement. You can bush down to 1/2. Your valve needs to say 24v 60hz .23A (or close)3.5"WC(2.5" - 5.0). This unit also has an ECO (energy cutout)that hooks to a limit switch or fuse. You could jump this out if your furnace doesn't have a limit. Hope this helps.
*36C67-176 *by Robertshaw is an older Standing Pilot Gas Valve used primarily on older mobile home furnaces. These older furnaces are known to have cracked heat exchangers The valve pex supply sells will work. You will need an LP gas conversion kit if you don’t have natural gas. Unless you are familiar with heating system repair and before spending the money on a new gas valve I would have the furnace inspected by a qualified contractor
Customer needs to use universal White and Rodgers Gas Valve 36C03-333. This valve will work for 24VAC furnace with pilot flame all time on. It has different reducing bushings 1/2" to 3/8" and 3/4" to 1/2". Valve body itself has input 1/2" and output 3/4". Use with this valve 24V W-R type HO6 thermocouple. It come in 18", 24", 36" lengths. Use jumper (included) to jump E..O.C terminals.
We cannot reference model number V813A1016. We can tell you that Honeywell lists V800A1070 as the functional replacement for V8139A1016 (if that's the part you mean).
York part S1-026-31241-700 is the recommended replacement. It is an OEM part made by Honeywell for York that is still labelled with the VR8200H1129 number.
Robertshaw part 700-408 is the recommended replacement for the obsolete 7000AER. We cannot confirm that this valve would work in its stead.
Possibly, but York part S1-7956-336P is the recommended replacement for 7656A3261.
The manufacturer recommends 36C03-433 as the replacement for 36C03-205.