Apply to be a TradeMaster!
Filter menu expanded

Filters

471,048 items
Reset

SORT

Wilo Top S Pump Parts

Help Face
Need a little help?
471048 items
Grid
List
Compare
Product Image of R48573-012 Txv Assy (Indoor), 91W17
$325.67 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 208/230V 1 Ph R410A 15200 BTU Compressor, 91W66
$1,769.95 each
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of Pre-Filters 18" x 18" x 4" (6 Pack), 910217164
$499.29 each
In Stock
Get 2 by Wed, Dec 2
In Stock
Get 2 by Wed, Dec 2
Compare
Product Image of K-1500SP-B Sectional Machine w/ A-1 Drain Cleaning Mitt, A-12 Pin Key Plus,C-14 3 Carrier Cable Combo Kit
$5,997.56
$5,697.56 each
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of Vent Collar, 5-inch Diameter, 9106
$16.99 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Capscrew Steel 1/4-20x1/2
Capscrew Steel 1/4-20x1/2
SKU: 911117-104
Armstrong Pumps
SKU: 911117-104
$4.84 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 9188PUB CutPro Kevlar Comfort Aramid Shell Cut Resistant Work Gloves w/ PU Coated Palm & Fingertips (Medium)
$16.73 each
In Stock
Get 2 by Thu, Dec 3 - Fri, Dec 4
In Stock
Get 2 by Thu, Dec 3 - Fri, Dec 4
Compare
Product Image of G7 Door Set, A, Brz, 904771
G7 Door Set, A, Brz, 904771
SKU: 904771
Nordyne
SKU: 904771
Brand: Nordyne
$199.06 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of G7 Door Set, B, Brz, 904772
G7 Door Set, B, Brz, 904772
SKU: 904772
Nordyne
SKU: 904772
Brand: Nordyne
$225.49 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Flue Collector Mi-08 Mi5001-3, 90515
$509.94 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Tube Evaporator Water Ice 22, 9051506-01
$86.60 each
In Stock
Get 1 by Wed, Dec 2
In Stock
Get 1 by Wed, Dec 2
Compare
Product Image of Tube Purge/pump, 9051630-01
Tube Purge/pump, 9051630-01
SKU: 9051630-01
Ice-O-Matic
SKU: 9051630-01
Brand: Ice-O-Matic
$53.60 each
In Stock
Get 10 by Wed, Dec 2
In Stock
Get 10 by Wed, Dec 2
Compare
Product Image of Tube Upper Water, 9051780-01
Tube Upper Water, 9051780-01
SKU: 9051780-01
Ice-O-Matic
SKU: 9051780-01
Brand: Ice-O-Matic
$65.24 each
In Stock
Get 10 by Wed, Dec 2
In Stock
Get 10 by Wed, Dec 2
Compare
Product Image of Pump Insert, 9051862-01
Pump Insert, 9051862-01
SKU: 9051862-01
Ice-O-Matic
SKU: 9051862-01
Brand: Ice-O-Matic
$30.40 each
In Stock
Get 1 by Wed, Dec 2
In Stock
Get 1 by Wed, Dec 2
Compare
Product Image of 24" Condor Magnetic Box Level w/ Optivision & Plumb Site
$55.59 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Check Valve Seat Kit 3/4" - 1-1/4" for LF825Y/LF825YA
$83.39 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of PC Board Assembly, 905000006
PC Board Assembly, 905000006
SKU: 905000006
Rinnai
SKU: 905000006
Brand: Rinnai
$202.17 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Survivor Nylon Handheld Flashlight, LED, 13 Hr Max Run Time, 4 Light Modes, Orange, 90503
$218.56 each
In Stock
Get 8 by Thu, Dec 3 - Fri, Dec 4
In Stock
Get 8 by Thu, Dec 3 - Fri, Dec 4
Compare
Product Image of Flue Collector Mi/mihii-03, 90510
$240.14 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Burner Support 211a-04, 90585
$79.55 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Burner Support Channel for 28-1/8" (714 mm) Wide Base Panel, 90587
$109.29 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 905 Synthetic Leather Palm Mechanics Gloves w/ G-Shaped Foam Palm Padding (Medium)
$21.61 each
In Stock
Get 2 by Thu, Dec 3 - Fri, Dec 4
In Stock
Get 2 by Thu, Dec 3 - Fri, Dec 4
Compare
Product Image of Ctn Burner Mtg Plt Sc1000, 90604
$936.40 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Curtain Splash Lg W/ Ag, 9051154-12
Curtain Splash Lg W/ Ag, 9051154-12
SKU: 9051154-12
Ice-O-Matic
SKU: 9051154-12
Brand: Ice-O-Matic
$323.55 each
In Stock
Get 10 by Wed, Dec 2
In Stock
Get 10 by Wed, Dec 2
Compare
Product Image of Ygrille Front Iceu Black, 9051515-01
Ygrille Front Iceu Black, 9051515-01
SKU: 9051515-01
Ice-O-Matic
SKU: 9051515-01
Brand: Ice-O-Matic
$71.35 each
In Stock
Get 5 by Wed, Dec 2
In Stock
Get 5 by Wed, Dec 2
Compare
Product Image of Grille Front Small, 9051531-01
Grille Front Small, 9051531-01
SKU: 9051531-01
Ice-O-Matic
SKU: 9051531-01
Brand: Ice-O-Matic
$88.32 each
In Stock
Get 1 by Wed, Dec 2
In Stock
Get 1 by Wed, Dec 2
Compare
Product Image of Flue Collector Mi-09 Mi5001-4, 90516
$554.09 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Check Spring Kit 1-1/2"-2" for 805Y Series
$299.40 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of NEMA Size 1, 600 VAC, Thermal NEMA Overload Relay For Motor Logic, 9065SF120
$230.20 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Block 63-05 Kd, 90686
$7,088.02 each
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 4" x 2" MegaPress XL 316 Stainless Steel Street Reducer
$450.10 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Pressure Switch 480VAC 10 Amp G +Options, 9012GAW25
$539.41 each
Out of Stock
Get it by Tue, Dec 15 - Tue, Dec 22
Out of Stock
Get it by Tue, Dec 15 - Tue, Dec 22
Compare
Product Image of Pressure Switch 480VAC 10A G RESTRICTED, 9012GAW4S126
$402.48 each
Out of Stock
Get it by Tue, Dec 15 - Tue, Dec 22
Out of Stock
Get it by Tue, Dec 15 - Tue, Dec 22
Compare
Product Image of Pressure Switch 480VAC 10 Amp G +Options, 9012GCW23
$905.20 each
Out of Stock
Get it by Tue, Dec 15 - Tue, Dec 22
Out of Stock
Get it by Tue, Dec 15 - Tue, Dec 22
Compare
Product Image of Pressure Switch 480VAC 10 Amp G +Options, 9012GCW3
$786.59 each
Out of Stock
Get it by Tue, Dec 15 - Tue, Dec 22
Out of Stock
Get it by Tue, Dec 15 - Tue, Dec 22
Compare
Product Image of ADRI 3/8" ODF Discharge Bypass Valve, Internally Equalized (0/75 PSIG)
$322.85 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of ADRIE 3/8" ODF Discharge Bypass Valve, Externally Equalized (0/75 PSIG)
$322.85 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Kit Mih Bvs Repair, 90593
$73.97 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Damper (LP), 906000018
Damper (LP), 906000018
SKU: 906000018
Rinnai
SKU: 906000018
Brand: Rinnai
$3.24 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of NEMA Size 2 Melting Alloy Replacement Overload Relay (600VAC), 9065SDO8
$234.16 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of NEMA Size 1 Melting Alloy Separate Mount Overload Relay (600VAC), 9065SEO5
$155.04 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Comb Floor Base Yy2011 Ctn, 90700
$653.17 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Block Wbv-04 Steam Close Kd, 90708
$5,403.68 each
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 1 Pole, 120 Volt, Fuse Block 1/4" Diameter x 1-1/4" Fuse Length, 9070FB1A
$151.82 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Transformer Cover, for Type T & TF Transformers, 9070FSC1
$31.57 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Top Mount Fuse Block Control Transformer (300VA, 1PH), 9070TF300D5
$517.11 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Pressure Switch 480VAC 10 Amp G +Options, 9012GDW2
$399.60 each
Out of Stock
Get it by Tue, Dec 15 - Tue, Dec 22
Out of Stock
Get it by Tue, Dec 15 - Tue, Dec 22
Compare
Product Image of Pressure Switch, 480 V, 10 Amp
$950.00 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Resources
FAQs, Manuals & Videos
Articles
More About Wilo Top S Pump Parts

Wilo Top S pump parts keep the Wilo Top S line of hydronic circulator pumps running in residential and light commercial heating and cooling systems. Wilo Top S circulators move hot or chilled water through hydronic piping in boiler, radiant, and fan coil applications, and replacement parts extend the service life of pumps already installed in the field. Common parts include motor cartridges, seal kits, gaskets, and control modules that wear or fail well before the pump housing itself needs replacement. Technicians servicing a Wilo Top S pump typically diagnose whether the issue is electrical, mechanical, or related to a worn wet end before ordering parts. Stocking the right cartridge and seal combination for a given pump size shortens repair time on a callback. Sourcing genuine Wilo replacement parts helps maintain the pump's original flow and efficiency performance rather than settling for a full pump swap.

Subcategories

  • Motor Cartridges: Motor cartridges contain the wet-rotor motor assembly that drives the pump impeller. Technicians replace a cartridge when the motor windings fail or bearings wear out, since the cartridge can typically be swapped without removing the pump body from the piping. Matching cartridge voltage and pump size to the installed housing is essential for proper fit. Replacing the cartridge alone is usually faster and less disruptive than replacing the entire pump.
  • Seal and Gasket Kits: Seal and gasket kits address leaks at the pump housing and cartridge interface, a common failure point in circulators that run continuously through a heating season. Technicians inspect for mineral buildup or a hardened gasket before assuming the pump body itself is damaged. Replacing seals proactively during scheduled maintenance can prevent a leak from becoming a no-heat emergency call. Kits are sized to match specific Wilo Top S pump models.
  • Control Modules: Control modules on variable-speed Wilo Top S pumps manage speed settings and communicate operating status. A failed module often causes the pump to run at a fixed speed or stop responding to system demand. Technicians troubleshoot wiring and power supply before replacing a module outright. Choosing the correct module version for the pump's control type avoids compatibility issues.
  • Flanges and Mounting Hardware: Flanges and mounting hardware connect the Wilo Top S pump body to the system piping and support proper alignment. Worn or corroded flange gaskets are a frequent source of slow leaks around the pump connection points. Technicians replace flange hardware during a full pump service to prevent recurring leaks. Correct flange sizing keeps the pump properly aligned with existing piping runs.
  • Buying Guide

    Ordering the correct Wilo Top S pump parts starts with confirming the exact pump model and voltage printed on the unit's nameplate, since cartridges and control modules are not interchangeable across the full Top S lineup. Technicians should determine whether the pump uses a fixed-speed or variable-speed motor cartridge before ordering a replacement, since installing the wrong type can leave the system without proper speed control. When a pump is leaking, checking whether the failure is at the seal, the gasket, or a cracked housing helps determine whether a seal kit will resolve the issue or a full cartridge or pump replacement is needed. For control modules, confirming the communication protocol the building automation system expects prevents a mismatch between the new module and existing controls. Contractors stocking Wilo Top S pump parts for commercial service routes often keep cartridges and seal kits on hand for the pump sizes most common in their service area, since hydronic systems can fail without much warning during cold weather. Reviewing the pump's original installation documentation, when available, helps confirm the exact part numbers needed and reduces the chance of ordering an incompatible component. Replacing worn parts on a Wilo Top S pump promptly, rather than waiting for a full failure, typically costs less in labor than an emergency pump swap during peak heating season.

    Frequently Asked Questions

    Can a Wilo Top S motor cartridge be replaced without draining the whole system?

    Most Wilo Top S pumps allow the cartridge to be removed while isolating the pump with flange-mounted isolation valves, limiting water loss to the pump body itself. Systems without isolation valves will require draining before cartridge replacement. Checking for isolation valves ahead of the service call helps technicians plan the repair more efficiently.

    What typically causes a Wilo Top S pump to run noisy?

    Noise often points to air trapped in the system, a worn bearing inside the motor cartridge, or debris caught in the impeller. Bleeding air from the system is usually the first troubleshooting step before replacing any parts. Persistent grinding or humming after bleeding usually indicates a cartridge replacement is needed.

    How do I identify the correct replacement seal kit for a Wilo Top S pump?

    The pump's model number and size, found on the nameplate, determine the correct seal kit, since kits vary by pump body size. Technicians should record this information before removing the pump for service. Ordering by nameplate model number avoids fit issues with the wrong kit.

    Why would a variable-speed Wilo Top S pump stop responding to a building automation system?

    A failed or disconnected control module is a common cause, along with wiring faults at the communication terminals. Technicians should verify power and signal wiring before replacing the module. Confirming the module's communication protocol matches the automation system prevents recurring issues after replacement.

    Is it possible to upgrade a fixed-speed Wilo Top S pump to variable-speed using replacement parts?

    Fixed-speed and variable-speed Wilo Top S pumps use different motor cartridges and control architectures, so an upgrade generally requires a cartridge designed for variable-speed operation along with a compatible control module. Confirming the pump housing supports the variable-speed cartridge is an important step before ordering parts. Contractors should check manufacturer documentation to confirm compatibility before attempting the upgrade.