Apply to be a TradeMaster!
Filter menu expanded

Filters

460,971 items
Reset

SORT

Wilo Top S Pump Parts

Help Face
Need a little help?
460971 items
Grid
List
Compare
Product Image of Vav Slave Diffuser Retrofit Kit For 6" Neck (Includes Mounting Screws), VD-RK-06-SD
Vav Slave Diffuser Retrofit Kit For 6" Neck (Includes Mounting Screws), VD-RK-06-SD
SKU: VD-RK-06-SD
iO HVAC Controls
SKU: VD-RK-06-SD
$347.59 each
In Stock
Get 2 by Mon, Nov 30 - Wed, Dec 2
In Stock
Get 2 by Mon, Nov 30 - Wed, Dec 2
Compare
Product Image of Vav Slave Diffuser Retrofit Kit For 12" Neck (Includes Mounting Screws), VD-RK-12-SD
$347.59 each
In Stock
Get 1 by Mon, Nov 30 - Wed, Dec 2
In Stock
Get 1 by Mon, Nov 30 - Wed, Dec 2
Compare
Product Image of VD2-780 Parts - VD2 780 Vitorond 200 Oil/Gas-fired Boilernot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Relay Ovld 0.40-0.60a, V09420
Relay Ovld 0.40-0.60a, V09420
SKU: V09420
AAON
SKU: V09420
Brand: AAON
$92.74 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Fan Coil Unit Cxb-06 4r Noheat, V11330
Fan Coil Unit Cxb-06 4r Noheat, V11330
SKU: V11330
AAON
SKU: V11330
Brand: AAON
$4,525.88 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Sound Blanket Zp103 Compressor, V12130
Sound Blanket Zp103 Compressor, V12130
SKU: V12130
AAON
SKU: V12130
Brand: AAON
$493.00 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Hinge Cont Stainless Steel 2.00 x 90.00, V12320
$77.29 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 03.45W12B0 Plenum Wheel, V15650
03.45W12B0 Plenum Wheel, V15650
SKU: V15650
AAON
SKU: V15650
Brand: AAON
$1,013.54 each
In Stock
Get 1 by Wed, Nov 25
In Stock
Get 1 by Wed, Nov 25
Compare
Product Image of 3/4hp 460v 1140rpm 48y Cfm Motor, V94280
3/4hp 460v 1140rpm 48y Cfm Motor, V94280
SKU: V94280
AAON
SKU: V94280
Brand: AAON
$1,083.39 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of VE75C3401 Electric Unit Heater, Vertical, 600V, 7.5 kW
$2,708.73 each
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of 1/2" Threaded Union 2Cv 24V 2 Positionnc Aux, VE24112NEP2.04530S
$245.70 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Element Ht Thermolec, V16240
Element Ht Thermolec, V16240
SKU: V16240
AAON
SKU: V16240
Brand: AAON
$641.42 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Pump Boiler, V18940
Pump Boiler, V18940
SKU: V18940
AAON
SKU: V18940
Brand: AAON
$931.00 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Valve, Gas, Dungs, V2022300
Valve, Gas, Dungs, V2022300
SKU: V2022300
Laars
SKU: V2022300
Brand: Laars
$9,661.57 each
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of VCA60C2C/P1254403C Parts - Amana Remote Condensing Unitnot-to-sell-product
VCA60C2C/P1254403C Parts - Amana Remote Condensing Unit
SKU: VCA60C2C/P1254403C
Goodman-Amana
SKU: VCA60C2C/P1254403C
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of 10" Vinyl Circular Saw Blade
10" Vinyl Circular Saw Blade
SKU: VCB2-EV
Malco
SKU: VCB2-EV
Brand: Malco
$21.00 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Motor 1.5/3/208-230 Teao, V21370
Motor 1.5/3/208-230 Teao, V21370
SKU: V21370
AAON
SKU: V21370
Brand: AAON
$1,124.72 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of VCC36C2A/P1246210C Parts - Amana Remote Condensing Unitnot-to-sell-product
VCC36C2A/P1246210C Parts - Amana Remote Condensing Unit
SKU: VCC36C2A/P1246210C
Goodman-Amana
SKU: VCC36C2A/P1246210C
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of Coil Condenser 58.0x 52.0 25mm Mc, V4942Q
$2,268.57 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Coil Condenser 58.0x 52.0 25mm Mc, V4942R
$3,335.99 each
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of 1/8" to 1/2" Step Drill Bit w/ 13 Hole Sizes
$35.86 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Coil Condenser 59.9x 48.1 1r23f Mc, V2645Q
$2,383.84 each
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Fuse Elec 90a/600v Cl J Td, V27200
Fuse Elec 90a/600v Cl J Td, V27200
SKU: V27200
AAON
SKU: V27200
Brand: AAON
$80.64 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Cont Aux Hartland Hcd Series, V29750
Cont Aux Hartland Hcd Series, V29750
SKU: V29750
AAON
SKU: V29750
Brand: AAON
$38.59 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Solder Silver 452 45% Blue, V29850
Solder Silver 452 45% Blue, V29850
SKU: V29850
AAON
SKU: V29850
Brand: AAON
$200.80 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 0.88 Fitting Cu Saddle Tube, V30460
0.88 Fitting Cu Saddle Tube, V30460
SKU: V30460
AAON
SKU: V30460
Brand: AAON
$53.08 each
In Stock
Get 4 by Wed, Nov 25
In Stock
Get 4 by Wed, Nov 25
Compare
Product Image of Seal Pump Mechanical, V50480
Seal Pump Mechanical, V50480
SKU: V50480
AAON
SKU: V50480
Brand: AAON
$380.83 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Cap Run 25+5mfd 440v, V3099B
Cap Run 25+5mfd 440v, V3099B
SKU: V3099B
AAON
SKU: V3099B
Brand: AAON
$17.50 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Gasket Chiller R07730, V34620
Gasket Chiller R07730, V34620
SKU: V34620
AAON
SKU: V34620
Brand: AAON
$225.32 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Ground Motor Shaft 1.63 Split, V39623
Ground Motor Shaft 1.63 Split, V39623
SKU: V39623
AAON
SKU: V39623
Brand: AAON
$1,829.19 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 3/4" NPT High Pressure Industrial Gas Valve w/ On-Off Safety Shut-Off
$899.38 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Sequencer Heat 2t/3s Hs24a345, V5232B
Sequencer Heat 2t/3s Hs24a345, V5232B
SKU: V5232B
AAON
SKU: V5232B
Brand: AAON
$50.23 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Sequencer Heat 2t/4s Hs24a346, V5233B
Sequencer Heat 2t/4s Hs24a346, V5233B
SKU: V5233B
AAON
SKU: V5233B
Brand: AAON
$54.58 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 230v3ph 164,000btu R-22 Comp, V5314B
230v3ph 164,000btu R-22 Comp, V5314B
SKU: V5314B
AAON
SKU: V5314B
Brand: AAON
$11,260.18 each
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of 460v3ph 53,400btu R22 Recpcomp, V54430
460v3ph 53,400btu R22 Recpcomp, V54430
SKU: V54430
AAON
SKU: V54430
Brand: AAON
$2,079.09 each
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of 208-230v 1100rpm Ecm Motor , V40170
208-230v 1100rpm Ecm Motor , V40170
SKU: V40170
AAON
SKU: V40170
Brand: AAON
$1,515.64 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of UCG-80H-199-3X Parts - Commander Series Atmospheric Vent Water Heater, LPnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Switch Fcs 100-470 Psi Adj, V41090
Switch Fcs 100-470 Psi Adj, V41090
SKU: V41090
AAON
SKU: V41090
Brand: AAON
$214.77 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Fuse Holder, 1 Pole, DIN Rail Mount, 600 VAC/VDC, 30A, USCC1I
$51.37 each
In Stock
Get 12 by Fri, Nov 27 - Mon, Nov 30
In Stock
Get 12 by Fri, Nov 27 - Mon, Nov 30
Compare
Product Image of Distributor, V60510
Distributor, V60510
SKU: V60510
AAON
SKU: V60510
Brand: AAON
$1,372.81 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 290f Limit Switch, V65400
290f Limit Switch, V65400
SKU: V65400
AAON
SKU: V65400
Brand: AAON
$66.26 each
In Stock
Get 2 by Wed, Nov 25
In Stock
Get 2 by Wed, Nov 25
Compare
Product Image of 3/4" 2-Way Normally Closed V710(B) Quick Opening Trim Hydramotor Valve Body
$1,080.20 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Aluminum Gas Valve Body 3/4" Linear Trim
$2,830.11 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of UCG-80H-199-5N Parts - Commander Series Atmospheric Vent Water Heater, NGnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Filter Drier Liq Line .25 Odf, V4331B
Filter Drier Liq Line .25 Odf, V4331B
SKU: V4331B
AAON
SKU: V4331B
Brand: AAON
$21.49 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Filter Drier Rep Dcr .875, V4373B
Filter Drier Rep Dcr .875, V4373B
SKU: V4373B
AAON
SKU: V4373B
Brand: AAON
$252.35 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Wheel Fan 22.5, V46570
Wheel Fan 22.5, V46570
SKU: V46570
AAON
SKU: V46570
Brand: AAON
$7,579.66 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Underdeck Clamp Kit for 3" & 4" PRD900 Series Roof Drains, UDC990
$27.63 each
Out of Stock
Get it by Wed, Dec 2 - Fri, Dec 4
Out of Stock
Get it by Wed, Dec 2 - Fri, Dec 4
Resources
FAQs, Manuals & Videos
Articles
More About Wilo Top S Pump Parts

Wilo Top S pump parts keep the Wilo Top S line of hydronic circulator pumps running in residential and light commercial heating and cooling systems. Wilo Top S circulators move hot or chilled water through hydronic piping in boiler, radiant, and fan coil applications, and replacement parts extend the service life of pumps already installed in the field. Common parts include motor cartridges, seal kits, gaskets, and control modules that wear or fail well before the pump housing itself needs replacement. Technicians servicing a Wilo Top S pump typically diagnose whether the issue is electrical, mechanical, or related to a worn wet end before ordering parts. Stocking the right cartridge and seal combination for a given pump size shortens repair time on a callback. Sourcing genuine Wilo replacement parts helps maintain the pump's original flow and efficiency performance rather than settling for a full pump swap.

Subcategories

  • Motor Cartridges: Motor cartridges contain the wet-rotor motor assembly that drives the pump impeller. Technicians replace a cartridge when the motor windings fail or bearings wear out, since the cartridge can typically be swapped without removing the pump body from the piping. Matching cartridge voltage and pump size to the installed housing is essential for proper fit. Replacing the cartridge alone is usually faster and less disruptive than replacing the entire pump.
  • Seal and Gasket Kits: Seal and gasket kits address leaks at the pump housing and cartridge interface, a common failure point in circulators that run continuously through a heating season. Technicians inspect for mineral buildup or a hardened gasket before assuming the pump body itself is damaged. Replacing seals proactively during scheduled maintenance can prevent a leak from becoming a no-heat emergency call. Kits are sized to match specific Wilo Top S pump models.
  • Control Modules: Control modules on variable-speed Wilo Top S pumps manage speed settings and communicate operating status. A failed module often causes the pump to run at a fixed speed or stop responding to system demand. Technicians troubleshoot wiring and power supply before replacing a module outright. Choosing the correct module version for the pump's control type avoids compatibility issues.
  • Flanges and Mounting Hardware: Flanges and mounting hardware connect the Wilo Top S pump body to the system piping and support proper alignment. Worn or corroded flange gaskets are a frequent source of slow leaks around the pump connection points. Technicians replace flange hardware during a full pump service to prevent recurring leaks. Correct flange sizing keeps the pump properly aligned with existing piping runs.
  • Buying Guide

    Ordering the correct Wilo Top S pump parts starts with confirming the exact pump model and voltage printed on the unit's nameplate, since cartridges and control modules are not interchangeable across the full Top S lineup. Technicians should determine whether the pump uses a fixed-speed or variable-speed motor cartridge before ordering a replacement, since installing the wrong type can leave the system without proper speed control. When a pump is leaking, checking whether the failure is at the seal, the gasket, or a cracked housing helps determine whether a seal kit will resolve the issue or a full cartridge or pump replacement is needed. For control modules, confirming the communication protocol the building automation system expects prevents a mismatch between the new module and existing controls. Contractors stocking Wilo Top S pump parts for commercial service routes often keep cartridges and seal kits on hand for the pump sizes most common in their service area, since hydronic systems can fail without much warning during cold weather. Reviewing the pump's original installation documentation, when available, helps confirm the exact part numbers needed and reduces the chance of ordering an incompatible component. Replacing worn parts on a Wilo Top S pump promptly, rather than waiting for a full failure, typically costs less in labor than an emergency pump swap during peak heating season.

    Frequently Asked Questions

    Can a Wilo Top S motor cartridge be replaced without draining the whole system?

    Most Wilo Top S pumps allow the cartridge to be removed while isolating the pump with flange-mounted isolation valves, limiting water loss to the pump body itself. Systems without isolation valves will require draining before cartridge replacement. Checking for isolation valves ahead of the service call helps technicians plan the repair more efficiently.

    What typically causes a Wilo Top S pump to run noisy?

    Noise often points to air trapped in the system, a worn bearing inside the motor cartridge, or debris caught in the impeller. Bleeding air from the system is usually the first troubleshooting step before replacing any parts. Persistent grinding or humming after bleeding usually indicates a cartridge replacement is needed.

    How do I identify the correct replacement seal kit for a Wilo Top S pump?

    The pump's model number and size, found on the nameplate, determine the correct seal kit, since kits vary by pump body size. Technicians should record this information before removing the pump for service. Ordering by nameplate model number avoids fit issues with the wrong kit.

    Why would a variable-speed Wilo Top S pump stop responding to a building automation system?

    A failed or disconnected control module is a common cause, along with wiring faults at the communication terminals. Technicians should verify power and signal wiring before replacing the module. Confirming the module's communication protocol matches the automation system prevents recurring issues after replacement.

    Is it possible to upgrade a fixed-speed Wilo Top S pump to variable-speed using replacement parts?

    Fixed-speed and variable-speed Wilo Top S pumps use different motor cartridges and control architectures, so an upgrade generally requires a cartridge designed for variable-speed operation along with a compatible control module. Confirming the pump housing supports the variable-speed cartridge is an important step before ordering parts. Contractors should check manufacturer documentation to confirm compatibility before attempting the upgrade.