Apply to be a TradeMaster!
Filter menu expanded

Filters

471,064 items
Reset

SORT

Wilo Z-15 Pump Parts

Help Face
Need a little help?
471064 items
Grid
List
Compare
Product Image of Shower Drain Head, Cast Matte Stainless Ring & Strainer
$38.37 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 820SA48045V17A-A Parts -Bryant Preferred 80% AFUE 45000 Btuh 4-Way Multipoise Non-Condensing 33-1/3 Gas Furnacenot-to-sell-product
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Compare
Product Image of 820TA48090V17A-B Parts - Bryant Preferred Series 80% AFUE Two-Stage Gas Furnacenot-to-sell-product
Backorder
Get it by Fri, Feb 26 - Fri, May 21
Backorder
Get it by Fri, Feb 26 - Fri, May 21
Compare
Product Image of 810AJX024000AAAA Parts - Carrier Split System Heat Pumpnot-to-sell-product
810AJX024000AAAA Parts - Carrier Split System Heat Pump
SKU: 810AJX024000AAAA
Carrier
SKU: 810AJX024000AAAA
Brand: Carrier
Backorder
Get it by Fri, Feb 26 - Fri, May 21
Backorder
Get it by Fri, Feb 26 - Fri, May 21
Compare
Product Image of 1/2" 2-Way Normally Closed Pilot Operated Oxygen Service Solenoid Valve, 4 Cv (120v)
$325.99 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 810AJX036000ADAA Parts - Carrier Split System Heat Pumpnot-to-sell-product
810AJX036000ADAA Parts - Carrier Split System Heat Pump
SKU: 810AJX036000ADAA
Carrier
SKU: 810AJX036000ADAA
Brand: Carrier
Backorder
Get it by Fri, Feb 26 - Fri, May 21
Backorder
Get it by Fri, Feb 26 - Fri, May 21
Compare
Product Image of 230v 1ph Fan Motor 1/6 HP 1350 RPM
230v 1ph Fan Motor 1/6 HP 1350 RPM
SKU: 810S124B38C
Tecumseh
SKU: 810S124B38C
Brand: Tecumseh
$425.72 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 810SA36070E17A-B Parts - Bryant Legacy Line 80% AFUE Single-Stage Gas Furnacenot-to-sell-product
Backorder
Get it by Fri, Feb 26 - Fri, May 21
Backorder
Get it by Fri, Feb 26 - Fri, May 21
Compare
Product Image of 2-1/2" General Purpose Solenoid Valve (208v)
2-1/2" General Purpose Solenoid Valve (208v)
SKU: 8210G101-208V
Asco RedHat
SKU: 8210G101-208V
Brand: Asco RedHat
$1,683.50 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Arrow Hart Extra Heavy-Duty Single Receptacle, #14-10 Awg 15A, Healthcare, 125V, Ivory, 8210V
$24.18 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 1" Normally Closed 2-Way Solenoid Valve, 13 CV (120VAC) (Lead Free)
$478.45 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 810SB48070M17A-A Parts - Carrier Legacy 80% AFUE Gas Furnacenot-to-sell-product
810SB48070M17A-A Parts - Carrier Legacy 80% AFUE Gas Furnace
SKU: 810SB48070M17A-A
Carrier
SKU: 810SB48070M17A-A
Brand: Carrier
Backorder
Get it by Fri, Feb 26 - Fri, May 21
Backorder
Get it by Fri, Feb 26 - Fri, May 21
Compare
Product Image of 810SB48070M17A-B Parts - Carrier Legacy 80% AFUE Gas Furnacenot-to-sell-product
810SB48070M17A-B Parts - Carrier Legacy 80% AFUE Gas Furnace
SKU: 810SB48070M17A-B
Carrier
SKU: 810SB48070M17A-B
Brand: Carrier
Backorder
Get it by Fri, Feb 26 - Fri, May 21
Backorder
Get it by Fri, Feb 26 - Fri, May 21
Compare
Product Image of 810SB60135M24A-A Parts - Carrier Legacy 80% AFUE Gas Furnacenot-to-sell-product
810SB60135M24A-A Parts - Carrier Legacy 80% AFUE Gas Furnace
SKU: 810SB60135M24A-A
Carrier
SKU: 810SB60135M24A-A
Brand: Carrier
Backorder
Get it by Fri, Feb 26 - Fri, May 21
Backorder
Get it by Fri, Feb 26 - Fri, May 21
Compare
Product Image of Packaged Hardware Set w/ Gasket (S45, S46, S55, S57)
$35.33 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Silencer OSS1, 807000016
Silencer OSS1, 807000016
SKU: 807000016
Rinnai
SKU: 807000016
Brand: Rinnai
$90.02 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Silencer OSS2, 807000017
Silencer OSS2, 807000017
SKU: 807000017
Rinnai
SKU: 807000017
Brand: Rinnai
$90.02 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Silencer OSS3/4, 807000018
Silencer OSS3/4, 807000018
SKU: 807000018
Rinnai
SKU: 807000018
Brand: Rinnai
$69.71 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Pump UPS20-58 120V, 807000039
Pump UPS20-58 120V, 807000039
SKU: 807000039
Rinnai
SKU: 807000039
Brand: Rinnai
$937.48 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Plate Exchanger E110C, 807000055
Plate Exchanger E110C, 807000055
SKU: 807000055
Rinnai
SKU: 807000055
Brand: Rinnai
$652.15 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 1" 125# Ib Trap w/ Thermal Bucket, 813T-1-125
$1,236.37 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 1" 180# Ib Trap w/ Thermal Bucket, 813T-1-180
$1,236.37 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 1-1/2" x 1-1/2" x 3/4" ProPress 316 Stainless Steel Reducing Tee (P x P x FPT)
$333.97 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Bolt M 5X16 (5/Pack), 809000015
Bolt M 5X16 (5/Pack), 809000015
SKU: 809000015
Rinnai
SKU: 809000015
Brand: Rinnai
$14.84 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of GASKET CONDENSATE TRAY iCON2, 807000136
GASKET CONDENSATE TRAY iCON2, 807000136
SKU: 807000136
Rinnai
SKU: 807000136
Brand: Rinnai
$54.90 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of HYDROBLOCK RETURN SOLO, 807000165
HYDROBLOCK RETURN SOLO, 807000165
SKU: 807000165
Rinnai
SKU: 807000165
Brand: Rinnai
$66.11 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Plate HEX, Medium, 807000184
Plate HEX, Medium, 807000184
SKU: 807000184
Rinnai
SKU: 807000184
Brand: Rinnai
$162.43 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 6" PVC Schedule 80 30-Degree Elbow
6" PVC Schedule 80 30-Degree Elbow
SKU: 815-060
SKU: 815-060
$98.12 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Commercial Specification Grade Duplex Receptacle, #14-10 Awg, 20A, 250V, SideWire, Ivory, 6-20R, 815V-BOX
$8.59 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Commercial Specification Grade Duplex Receptacle, #14-10 Awg, 20A, 250V, SideWire, White, 6-20R, 815W-BOX
$8.59 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 1/2" Socket CPVC Schedule 80 22.5° Elbow
1/2" Socket CPVC Schedule 80 22.5° Elbow
SKU: 816-005C
SKU: 816-005C
$5.51 each
BOX UP & SAVE 10%
$98.80 box of 20
$4.94 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 4" Socket CPVC Schedule 80 22.5° Elbow
4" Socket CPVC Schedule 80 22.5° Elbow
SKU: 816-040C
SKU: 816-040C
$103.94 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Three Way Valve Housing VC/O-Ring, 809000057
Three Way Valve Housing VC/O-Ring, 809000057
SKU: 809000057
Rinnai
SKU: 809000057
Brand: Rinnai
$226.74 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Bracket Q175S & Q205S, 809000066
Bracket Q175S & Q205S, 809000066
SKU: 809000066
Rinnai
SKU: 809000066
Brand: Rinnai
$47.75 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Cartridge Tool For 3 Way Valve, 809000128
Cartridge Tool For 3 Way Valve, 809000128
SKU: 809000128
Rinnai
SKU: 809000128
Brand: Rinnai
$73.62 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Snap Lock Casing QP, 809000136
Snap Lock Casing QP, 809000136
SKU: 809000136
Rinnai
SKU: 809000136
Brand: Rinnai
$119.02 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Socket Fitting 15mm, 809000144
Socket Fitting 15mm, 809000144
SKU: 809000144
Rinnai
SKU: 809000144
Brand: Rinnai
$70.55 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 1-1/2" x 1-1/2" x 1" ProPress 316 Stainless Steel Reducing Tee (P x P x FPT)
$250.72 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 1-1/2" LF Bronze Flange Kit for E7B, E8B, E9B, E12B, E14B, E12B-TE, E14B-TE, E15B, E17B, H-52AB Pumps (Pair)
$113.72 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Assembly 4000 Sba Bf
Assembly 4000 Sba Bf
SKU: 816036-011
Armstrong Pumps
SKU: 816036-011
$559.22 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Assembly #6 Sba B&g Replacement Ab
$2,067.33 each
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Compare
Product Image of 6" PVC Schedule 80 EPDM Union 2000 (S x Spig)
$156.20 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 6" CPVC Schedule 80 Union 2000 w/ EPDM O-Ring Seal (Socket x Spigot)
$343.35 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 6" CPVC Schedule 80 EPDM Union 2000 (Socket x Socket)
$366.45 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 1" CPVC Schedule 80 EPDM Union 2000 (FPT x FPT)
1" CPVC Schedule 80 EPDM Union 2000 (FPT x FPT)
SKU: 8098-010C
SKU: 8098-010C
$44.68 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 1-1/4" FPT CPVC Schedule 80 90° Elbow
1-1/4" FPT CPVC Schedule 80 90° Elbow
SKU: 808-012C
SKU: 808-012C
(4)
$24.41 each
BOX UP & SAVE 9%
$223.30 box of 10
$22.33 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Casing H66-h67
Casing H66-h67
SKU: 816174-011
Armstrong Pumps
SKU: 816174-011
$1,266.22 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Impeller Assembly Bronze 4.75"
Impeller Assembly Bronze 4.75"
SKU: 816303-051
Armstrong Pumps
SKU: 816303-051
$557.38 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Resources
FAQs, Manuals & Videos
Articles
More About Wilo Z-15 Pump Parts

Wilo Z-15 pump parts are the replacement components contractors use to service and rebuild Z-15 wet-rotor circulator pumps found in residential and light commercial hydronic heating and hot water recirculation systems. The Z-15 is a single-speed, in-line circulator, and its most commonly replaced parts are the pump head, rotor and impeller assembly, and the mounting gaskets that seal the pump body to the piping flanges. Over years of continuous operation, mineral buildup and worn bearings inside the wet-rotor cartridge are the usual reasons a Z-15 needs a rebuild rather than a full replacement. Keeping gaskets, cartridges, and mounting hardware on hand lets a contractor return a system to service the same day instead of waiting on a full pump swap, which matters most on boiler systems where extended downtime affects a building's heat.

Subcategories

  • Pump Heads: Pump heads house the motor and electrical connections for the Z-15 circulator and bolt directly onto the wet-rotor cartridge below. Contractors replace a pump head when the motor windings fail or a bad capacitor stops the rotor from starting, rather than swapping the entire unit. Because the head separates from the wet end without draining the whole system in most installations, it's often the fastest single-part repair on a Z-15. Matching the voltage and speed rating to the original nameplate keeps the replacement head compatible with the existing wiring.
  • Rotor & Impeller Assemblies: The rotor and impeller assembly is the wet-rotor cartridge that spins inside the pump body to move water through the system. Mineral scale and sediment are the most common causes of a sluggish or seized rotor, especially in older cast iron hydronic loops. Replacing the assembly restores full flow without needing to replace the pump housing or motor head. A worn sleeve bearing inside the assembly is usually what causes the humming or grinding noise contractors hear before a Z-15 fails outright.
  • Mounting Gaskets & Flanges: Mounting gaskets seal the pump body against the flanges that connect it to the supply and return piping. A worn or improperly seated gasket is one of the most common sources of a slow weep leak at the pump union. Flanges themselves rarely need replacement unless they've been damaged during a prior installation or corroded from years of exposure to boiler water. Keeping the correct gasket size on hand avoids a return trip when a routine pump service uncovers a leak at the union.
  • Cartridge Seal Kits: Cartridge seal kits bundle the O-rings and shaft seals needed to reseal the wet-rotor cartridge after it's opened for cleaning or bearing replacement. Using a complete kit instead of individual seals reduces the chance of missing a small O-ring that causes a repeat callback. Seal kits are typically sized to the specific cartridge generation, so matching the kit to the pump's production era matters more than matching it to the overall Z-15 model name alone. A fresh seal kit is standard practice any time the cartridge is removed for service, even if the old seals look intact.
  • Buying Guide

    When sourcing Wilo Z-15 pump parts, start with the failure symptom rather than guessing at a full parts list. A pump that hums but doesn't spin usually points to a seized rotor or worn bearing, calling for a rotor and impeller assembly rather than a new pump head. A pump that won't start electrically, or trips a breaker, more often points to the motor windings or capacitor inside the pump head itself. Confirm the exact age and cartridge generation of the installed unit before ordering, since Wilo has updated the internal cartridge design over the years and parts from a newer cartridge don't always fit an older pump body. For jobs where the pump has been in continuous service for many years, rebuilding with a full cartridge seal kit alongside the rotor assembly is often more efficient than replacing components piecemeal, since it addresses wear across the whole wet end in one visit. Keep a small stock of the most commonly needed Wilo Z-15 pump parts, gaskets, seal kits, and a spare pump head, on hand for routine hydronic service calls, since these are the components most likely to fail from years of continuous operation. For a pump that's failed catastrophically or is several rebuilds in already, replacing the entire unit is often the more practical long-term choice over continuing to source individual parts.

    Frequently Asked Questions

    How do I know if my Wilo Z-15 needs a new pump head or a full rotor assembly?

    If the pump is silent and doesn't spin at all, check the motor head first, since that usually points to a failed capacitor or burned winding. If the pump hums or vibrates but the rotor won't turn, the wet-rotor cartridge itself is more likely the problem. Testing continuity at the motor terminals before ordering parts helps confirm which component actually failed.

    Can I rebuild a Z-15 without draining the whole heating system?

    In most installations, the pump head separates from the wet-rotor cartridge without opening the main piping, so a motor swap doesn't require draining the loop. Replacing the cartridge, gaskets, or flanges does require isolating and draining the pump section, though the rest of the system can often stay filled if isolation valves are present. Always confirm the specific installation has isolation valves before promising a no-drain repair.

    Why does my Z-15 keep leaking at the union even after a new gasket?

    A repeat leak after a gasket replacement is usually a sign the flange itself is corroded, warped, or wasn't torqued evenly during installation. Overtightening a new gasket can also distort it and cause the same leak to return. Checking the flange surface for pitting and torquing bolts in a cross pattern typically resolves a recurring union leak.

    How long does a Z-15 cartridge seal kit typically last?

    Seal life depends heavily on water quality and how often the system cycles, so there's no single fixed interval for every installation. Systems with harder water or more mineral content tend to wear seals faster than closed loops with treated water. Replacing the seal kit any time the cartridge is opened for service, rather than waiting for a visible leak, helps avoid a repeat callback.

    Is it worth rebuilding an older Z-15 or should I replace the whole pump?

    A rebuild makes sense when the pump body and flanges are still in good condition and only the wet-rotor cartridge or motor head has failed. Once a pump has needed several rebuilds over a short period, or the housing itself shows corrosion, replacing the entire unit is usually the more practical option. Weighing the age of the installation against the parts already on hand helps make that call quickly during a service visit.