Apply to be a TradeMaster!
Filter menu expanded

Filters

462,990 items
Reset

SORT

Wilo Z-15 Pump Parts

Help Face
Need a little help?
462990 items
Grid
List
Compare
Product Image of Hot Stick Holder, S-Hook
Hot Stick Holder, S-Hook
SKU: BC515S
Klein Tools
SKU: BC515S
Brand: Klein Tools
$198.00 each
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of 2-Man Bucket Cover
2-Man Bucket Cover
SKU: BC516C
Klein Tools
SKU: BC516C
Brand: Klein Tools
$288.19 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of LiftPro 20" Wall Mount System, BC600WA
$265.00 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 3/4" x 3/4" FPT Single Solenoid Gas Valve, 430,000 BTU (25V)
$192.87 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 4" 2-Way Normally Closed Industrial Butterfly Valve, 2-Position, 120V (175 PSI)
$1,285.57 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Retainer Scr 883 1/2 Npt, B3789-1
$82.02 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of LiftPro 24" Wall Mount System
LiftPro 24" Wall Mount System
SKU: BC700WA
Klein Tools
SKU: BC700WA
Brand: Klein Tools
$498.99 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of BCA48TA002A/P1177206C Parts - Amana Air Handlernot-to-sell-product
BCA48TA002A/P1177206C Parts - Amana Air Handler
SKU: BCA48TA002A/P1177206C
Goodman-Amana
SKU: BCA48TA002A/P1177206C
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of BCAA36C002A/P1102004C Parts - Amana Air Handlernot-to-sell-product
BCAA36C002A/P1102004C Parts - Amana Air Handler
SKU: BCAA36C002A/P1102004C
Goodman-Amana
SKU: BCAA36C002A/P1102004C
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of BCCB-T048AB Parts - Coleman Heat Pumpnot-to-sell-product
BCCB-T048AB Parts - Coleman Heat Pump
SKU: BCCB-T048AB
Coleman
SKU: BCCB-T048AB
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of BGM06008C Parts - Coleman Furnacenot-to-sell-product
BGM06008C Parts - Coleman Furnace
SKU: BGM06008C
Coleman
SKU: BGM06008C
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of BGM07512BD Parts - Coleman Furnacenot-to-sell-product
BGM07512BD Parts - Coleman Furnace
SKU: BGM07512BD
Coleman
SKU: BGM07512BD
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of BGM10016BXD Parts - Coleman Furnacenot-to-sell-product
BGM10016BXD Parts - Coleman Furnace
SKU: BGM10016BXD
Coleman
SKU: BGM10016BXD
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of BGTA180C2E Parts - Trane Central Air Conditionernot-to-sell-product
BGTA180C2E Parts - Trane Central Air Conditioner
SKU: BGTA180C2E
Trane
SKU: BGTA180C2E
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of BGTA736B1B Parts - Trane Central Air Conditionernot-to-sell-product
BGTA736B1B Parts - Trane Central Air Conditioner
SKU: BGTA736B1B
Trane
SKU: BGTA736B1B
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of BGTA872R4D00 Parts - Trane Central Air Conditionernot-to-sell-product
BGTA872R4D00 Parts - Trane Central Air Conditioner
SKU: BGTA872R4D00
Trane
SKU: BGTA872R4D00
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of 1-1/2" x 50' Long Flexible Liquidtight Conduit, Black, B2150
$469.91 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of B3CH060A06B Parts - York Heat Pumpnot-to-sell-product
B3CH060A06B Parts - York Heat Pump
SKU: B3CH060A06B
York
SKU: B3CH060A06B
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of B3CH060A46A/12-1991 Parts - York Heat Pumpnot-to-sell-product
B3CH060A46A/12-1991 Parts - York Heat Pump
SKU: B3CH060A46A/12-1991
York
SKU: B3CH060A46A/12-1991
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of BCCB-T060AC Parts - Coleman Heat Pumpnot-to-sell-product
BCCB-T060AC Parts - Coleman Heat Pump
SKU: BCCB-T060AC
Coleman
SKU: BCCB-T060AC
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of BCCB-X060AA Parts - Coleman Heat Pumpnot-to-sell-product
BCCB-X060AA Parts - Coleman Heat Pump
SKU: BCCB-X060AA
Coleman
SKU: BCCB-X060AA
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of BCEA24T001A/P9846207C Parts - Amana Air Handlernot-to-sell-product
BCEA24T001A/P9846207C Parts - Amana Air Handler
SKU: BCEA24T001A/P9846207C
Goodman-Amana
SKU: BCEA24T001A/P9846207C
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Door Gasket, 45.25" x 30.375" x 0.5, BCP00214
$184.00 each
In Stock
Get 3 by Wed, Nov 25
In Stock
Get 3 by Wed, Nov 25
Compare
Product Image of BCPH036XXX1DXXX/CPH036XXX1DXXXB Parts - Goodman Air Handlernot-to-sell-product
BCPH036XXX1DXXX/CPH036XXX1DXXXB Parts - Goodman Air Handler
SKU: BCPH036XXX1DXXX/CPH036XXX1DXXXB
Goodman
SKU: BCPH036XXX1DXXX/CPH036XXX1DXXXB
Brand: Goodman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of BGTC120A3B Parts - Trane Central Air Conditionernot-to-sell-product
BGTC120A3B Parts - Trane Central Air Conditioner
SKU: BGTC120A3B
Trane
SKU: BGTC120A3B
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of BGTE120C4A06 Parts - Trane Air Handlernot-to-sell-product
BGTE120C4A06 Parts - Trane Air Handler
SKU: BGTE120C4A06
Trane
SKU: BGTE120C4A06
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of BGU10016A/09-2001 Parts - Coleman Furnacenot-to-sell-product
BGU10016A/09-2001 Parts - Coleman Furnace
SKU: BGU10016A/09-2001
Coleman
SKU: BGU10016A/09-2001
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Model B22 12", 1/2" MPT x Sweat Inlet Hot & Cold Box Anti-Siphon Faucet w/ Metal Handle (Chrome)
$902.04 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of B4CH048A58B Parts - York Heat Pumpnot-to-sell-product
B4CH048A58B Parts - York Heat Pump
SKU: B4CH048A58B
York
SKU: B4CH048A58B
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of B4CH048A58C Parts - York Heat Pumpnot-to-sell-product
B4CH048A58C Parts - York Heat Pump
SKU: B4CH048A58C
York
SKU: B4CH048A58C
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Cartridges w/ Blank Insert Cartridge, Rail System (2 Pack)
$23.19 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of BGWA090C3E Parts - Trane Heat Pumpnot-to-sell-product
BGWA090C3E Parts - Trane Heat Pump
SKU: BGWA090C3E
Trane
SKU: BGWA090C3E
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of BGWA090C4C Parts - Trane Heat Pumpnot-to-sell-product
BGWA090C4C Parts - Trane Heat Pump
SKU: BGWA090C4C
Trane
SKU: BGWA090C4C
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of 2-1/2" Conduit, Safety Switch Plate Hub For Load Centers, Rb Devices, B250
$87.13 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 18kw 480v Heating Element, B5047-3-18KW-480V
18kw 480v Heating Element, B5047-3-18KW-480V
SKU: B5047-3-18KW-480V
Armstrong Air
SKU: B5047-3-18KW-480V
$1,834.00 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Bd, Sight Glass, BD710112101V
Bd, Sight Glass, BD710112101V
SKU: BD710112101V
Utica-Dunkirk
SKU: BD710112101V
$2.05 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Bd, 3-way Valve Block - System, BD710266901V
$217.17 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Bd, Gas Nozzle B&p D.5, 8, BD710458501V
Bd, Gas Nozzle B&p D.5, 8, BD710458501V
SKU: BD710458501V
Utica-Dunkirk
SKU: BD710458501V
$3.09 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of BGWE318G1A Parts - Trane Air Handlernot-to-sell-product
BGWE318G1A Parts - Trane Air Handler
SKU: BGWE318G1A
Trane
SKU: BGWE318G1A
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of BGWE424G1F Parts - Trane Air Handlernot-to-sell-product
BGWE424G1F Parts - Trane Air Handler
SKU: BGWE424G1F
Trane
SKU: BGWE424G1F
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of BH14NB042P0GAAAA Parts -Bryant Sentry - 3.5 Ton 14 SEER Residential Heat Pump Condensing Unitnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of B25AE03 Parts - Trane Central Air Conditionernot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Tank Lid Gasket Kit Cs-14, B5399
$792.11 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 10.75" 1 Groove Ci Sheave, 1-3/16", BK110X13/16
10.75" 1 Groove Ci Sheave, 1-3/16", BK110X13/16
SKU: BK110X13/16
Browning
SKU: BK110X13/16
Brand: Browning
$166.64 each
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of BA-15E36DWAAA1A Parts - Coleman Heat Pumpnot-to-sell-product
BA-15E36DWAAA1A Parts - Coleman Heat Pump
SKU: BA-15E36DWAAA1A
Coleman
SKU: BA-15E36DWAAA1A
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of BA-15E54ATBAA1A Parts - Coleman Heat Pumpnot-to-sell-product
BA-15E54ATBAA1A Parts - Coleman Heat Pump
SKU: BA-15E54ATBAA1A
Coleman
SKU: BA-15E54ATBAA1A
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of BA-15E72AWAAA1A Parts - Coleman Heat Pumpnot-to-sell-product
BA-15E72AWAAA1A Parts - Coleman Heat Pump
SKU: BA-15E72AWAAA1A
Coleman
SKU: BA-15E72AWAAA1A
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Resources
FAQs, Manuals & Videos
Articles
More About Wilo Z-15 Pump Parts

Wilo Z-15 pump parts are the replacement components contractors use to service and rebuild Z-15 wet-rotor circulator pumps found in residential and light commercial hydronic heating and hot water recirculation systems. The Z-15 is a single-speed, in-line circulator, and its most commonly replaced parts are the pump head, rotor and impeller assembly, and the mounting gaskets that seal the pump body to the piping flanges. Over years of continuous operation, mineral buildup and worn bearings inside the wet-rotor cartridge are the usual reasons a Z-15 needs a rebuild rather than a full replacement. Keeping gaskets, cartridges, and mounting hardware on hand lets a contractor return a system to service the same day instead of waiting on a full pump swap, which matters most on boiler systems where extended downtime affects a building's heat.

Subcategories

  • Pump Heads: Pump heads house the motor and electrical connections for the Z-15 circulator and bolt directly onto the wet-rotor cartridge below. Contractors replace a pump head when the motor windings fail or a bad capacitor stops the rotor from starting, rather than swapping the entire unit. Because the head separates from the wet end without draining the whole system in most installations, it's often the fastest single-part repair on a Z-15. Matching the voltage and speed rating to the original nameplate keeps the replacement head compatible with the existing wiring.
  • Rotor & Impeller Assemblies: The rotor and impeller assembly is the wet-rotor cartridge that spins inside the pump body to move water through the system. Mineral scale and sediment are the most common causes of a sluggish or seized rotor, especially in older cast iron hydronic loops. Replacing the assembly restores full flow without needing to replace the pump housing or motor head. A worn sleeve bearing inside the assembly is usually what causes the humming or grinding noise contractors hear before a Z-15 fails outright.
  • Mounting Gaskets & Flanges: Mounting gaskets seal the pump body against the flanges that connect it to the supply and return piping. A worn or improperly seated gasket is one of the most common sources of a slow weep leak at the pump union. Flanges themselves rarely need replacement unless they've been damaged during a prior installation or corroded from years of exposure to boiler water. Keeping the correct gasket size on hand avoids a return trip when a routine pump service uncovers a leak at the union.
  • Cartridge Seal Kits: Cartridge seal kits bundle the O-rings and shaft seals needed to reseal the wet-rotor cartridge after it's opened for cleaning or bearing replacement. Using a complete kit instead of individual seals reduces the chance of missing a small O-ring that causes a repeat callback. Seal kits are typically sized to the specific cartridge generation, so matching the kit to the pump's production era matters more than matching it to the overall Z-15 model name alone. A fresh seal kit is standard practice any time the cartridge is removed for service, even if the old seals look intact.
  • Buying Guide

    When sourcing Wilo Z-15 pump parts, start with the failure symptom rather than guessing at a full parts list. A pump that hums but doesn't spin usually points to a seized rotor or worn bearing, calling for a rotor and impeller assembly rather than a new pump head. A pump that won't start electrically, or trips a breaker, more often points to the motor windings or capacitor inside the pump head itself. Confirm the exact age and cartridge generation of the installed unit before ordering, since Wilo has updated the internal cartridge design over the years and parts from a newer cartridge don't always fit an older pump body. For jobs where the pump has been in continuous service for many years, rebuilding with a full cartridge seal kit alongside the rotor assembly is often more efficient than replacing components piecemeal, since it addresses wear across the whole wet end in one visit. Keep a small stock of the most commonly needed Wilo Z-15 pump parts, gaskets, seal kits, and a spare pump head, on hand for routine hydronic service calls, since these are the components most likely to fail from years of continuous operation. For a pump that's failed catastrophically or is several rebuilds in already, replacing the entire unit is often the more practical long-term choice over continuing to source individual parts.

    Frequently Asked Questions

    How do I know if my Wilo Z-15 needs a new pump head or a full rotor assembly?

    If the pump is silent and doesn't spin at all, check the motor head first, since that usually points to a failed capacitor or burned winding. If the pump hums or vibrates but the rotor won't turn, the wet-rotor cartridge itself is more likely the problem. Testing continuity at the motor terminals before ordering parts helps confirm which component actually failed.

    Can I rebuild a Z-15 without draining the whole heating system?

    In most installations, the pump head separates from the wet-rotor cartridge without opening the main piping, so a motor swap doesn't require draining the loop. Replacing the cartridge, gaskets, or flanges does require isolating and draining the pump section, though the rest of the system can often stay filled if isolation valves are present. Always confirm the specific installation has isolation valves before promising a no-drain repair.

    Why does my Z-15 keep leaking at the union even after a new gasket?

    A repeat leak after a gasket replacement is usually a sign the flange itself is corroded, warped, or wasn't torqued evenly during installation. Overtightening a new gasket can also distort it and cause the same leak to return. Checking the flange surface for pitting and torquing bolts in a cross pattern typically resolves a recurring union leak.

    How long does a Z-15 cartridge seal kit typically last?

    Seal life depends heavily on water quality and how often the system cycles, so there's no single fixed interval for every installation. Systems with harder water or more mineral content tend to wear seals faster than closed loops with treated water. Replacing the seal kit any time the cartridge is opened for service, rather than waiting for a visible leak, helps avoid a repeat callback.

    Is it worth rebuilding an older Z-15 or should I replace the whole pump?

    A rebuild makes sense when the pump body and flanges are still in good condition and only the wet-rotor cartridge or motor head has failed. Once a pump has needed several rebuilds over a short period, or the housing itself shows corrosion, replacing the entire unit is usually the more practical option. Weighing the age of the installation against the parts already on hand helps make that call quickly during a service visit.