Wilkins 950XL Double Check Valve Assemblies are backflow preventers built for low health hazard, non-potable applications where cross-connection protection is required by code. The assembly uses a wye pattern, short lay-length body with threaded end connections, rated for a maximum working pressure of 175 psi and a maximum working water temperature of 180 degrees Fahrenheit. Stainless steel springs, fasteners, and ball valve handles resist corrosion, while replaceable Noryl seats and silicone seal rings simplify field maintenance without replacing the entire assembly. Available in 3/4 inch through 2 inch sizes, the 950XL carries ASSE 1015, IAPMO, and CSA listings along with AWWA C510 compliance, which covers most jurisdictions requiring certified backflow protection. Contractors specify this assembly on irrigation systems, fire lines, and other non-potable services where a single check valve is not sufficient protection against backsiphonage or backpressure.
Subcategories
Buying Guide
Confirm the health hazard classification required for the connection point before selecting an assembly. Wilkins 950XL Double Check Valve Assemblies are listed for low health hazard, non-potable applications, which covers most irrigation and fire protection use, but a high hazard cross-connection needs a reduced pressure zone assembly instead. Match the size to the pipe run and expected flow rather than defaulting to the meter size, since an undersized assembly restricts flow and an oversized one adds unnecessary bulk and cost. Check local jurisdiction requirements, since many require ASSE 1015 listing, IAPMO or CSA listing, and AWWA C510 compliance before approving an installation, and the 950XL carries all of these. Consider access for annual testing. A standard 950XL requires enough clearance around the body to connect test cocks, while the 950XLT top-access variant speeds up testing in tight vaults or crawlspaces where full assembly removal is impractical. Verify the working pressure and temperature of the system against the assembly's 175 psi and 180 degree Fahrenheit ratings, since exceeding either voids the certification and creates a code violation. Check thread type and end connections against the existing pipe material to avoid an adapter that adds another failure point. Order replacement seat and seal kits alongside the assembly on older installations, since a full replacement is often faster than repeated field repair once seals start failing.
Frequently Asked Questions
What's the difference between the 950XL and 950XLT?
The 950XLT adds top-access covers that let a technician service internal check modules without disconnecting the assembly from the pipeline. Both variants share the same wye pattern body, working pressure rating of 175 psi, and certification listings. Choosing the XLT mainly comes down to how often the assembly needs annual testing and how much clearance exists around the installation. Tight vaults or crawlspaces favor the top-access design.
What sizes does the 950XL come in?
The 950XL is available in 3/4 inch, 1 inch, 1-1/2 inch, and 2 inch sizes. Smaller sizes typically serve residential and light commercial irrigation meters, while larger sizes handle higher-flow commercial and fire protection services. Sizing should match the pipe run and expected flow rather than the meter connection alone. Confirming the exact size against the existing line before ordering avoids a mismatch.
Is the 950XL rated for potable water protection?
The 950XL Double Check Valve Assembly is listed for low health hazard, non-potable applications such as irrigation and fire protection. Higher hazard cross-connections that involve potable water protection typically require a reduced pressure zone assembly instead. Checking the local water authority's cross-connection control requirements confirms which device type a given connection needs. Installing the wrong device type fails inspection even when the assembly itself is high quality.
What maintains the check valve seats over time?
Replaceable Noryl seats and silicone seal rings inside the 950XL allow a technician to rebuild the check modules without removing the entire assembly from the line. Stainless steel springs resist the corrosion that would otherwise weaken spring tension over years of service. Annual testing typically catches seat wear before it causes a failed backflow test. Keeping rebuild kits on hand speeds up repairs on older installations.
What pressure and temperature range does the 950XL handle?
The 950XL carries a maximum working water pressure of 175 psi and a maximum working water temperature of 180 degrees Fahrenheit. Hydrostatic test pressure is rated at 350 psi. Exceeding either the pressure or temperature rating voids the certification listing. Confirming system conditions against these ratings before installation avoids a code compliance issue later.