Pressure Switches are controls that open or close an electrical circuit when system pressure reaches a set point. The SupplyHouse listing includes Telemecanique (Square D) water pump switches, an air-pump switch, and a 3-pole toggle switch. The Pumptrol 9013FSG model with a 40/60 PSI setting, for example, covers a 5 to 65 psi range with a DPST switch. Cut-in and cut-out settings, differential, and contact form decide whether a switch suits a given pump and tank setup. Contractors who service jet, submersible, and reciprocating pumps choose a switch by those numbers, not by appearance. The 9013FSG water pump switches are diaphragm actuated and are UL Listed and CSA certified as commercial control equipment. Matching the factory setting and range to the application helps keep pump cycling predictable and limits repeat service calls.
Subcategories
Buying Guide
Start with the pump and the pressure settings it needs. Pump type matters as well, so confirm the switch is meant for the pump style on the job. The factory on/off setting, such as 30/50 or 40/60 psi, should match the system's target operating range. Confirm that the switch range covers those setpoints with room to adjust. The 40/60 PSI Pumptrol 9013FSG, for example, carries a 5 to 65 psi range, and a DPST model in the listing carries a 5 to 80 psi range.
Next, compare differential, the gap between cut-in and cut-out pressure. The water pump models listed show 15 to 30 psi, while the air-pump model shows 6 to 20 psi. A wider differential means longer run cycles and fewer starts, and a narrower one cycles the pump more often.
Then match the electrical side. Check contact form, amperage, and enclosure against the motor and panel. The listed water pump switches are DPST, the 40/60 PSI model lists 10 amp with a NEMA-1 enclosure, and the 4 to 45 psi air-pump model is also DPST. Choosing among Pressure Switches this way keeps the spec sheet, not guesswork, in charge of the order. Port size is the last check. The 30/50 PSI model uses a 1/4 inch FNPS port and lists no manual switch action or unloader.
Frequently Asked Questions
What do the two numbers in a pressure switch setting mean?
On a pressure switch such as the 30/50 PSI water pump model, the first number is the cut-in pressure and the second is the cut-out pressure. The factory setting on that model is 30/50 psi, and its range runs 5 to 65 psi. Adjust within the range to fit the system.
Can I run a pressure switch from this category on a submersible pump?
The Pumptrol 9013FSG water pump pressure switches are described as suitable for jet, submersible, and reciprocating pumps. Pressure switches should still be matched to the pump's pressure settings and the motor's electrical load. Check the model's range and amperage before installing.
What differential range do these water pump pressure switches offer?
The listed water pump pressure switches show a 15 to 30 psi differential. The air-pump pressure switch listed shows 6 to 20 psi. Differential sets the gap between cut-in and cut-out, so it affects how often the pump cycles.
Are the Square D pressure switches UL and CSA rated?
The product description for the 9013FSG water pump pressure switches states they are UL Listed and CSA certified as commercial control equipment. That rating is stated for the 9013FSG series, so pressure switches from other families need their own rating check.
What contact form and amperage do these pressure switches use?
The water pump and air-pump pressure switches in the listing are DPST. The 40/60 PSI model lists 10 amp with a NEMA-1 enclosure, and the DPST model with a 5 to 80 psi range also lists 10 amp. Confirm amperage against the motor load before ordering.