| Length (Inches): | 10" |
|---|---|
| Application: | 1/2" PEX |
| Material: | Aluminum |
| Tubing Type: | Oxygen Barrier |
You can use standard spray-foam insulation, but not the canned kind. For your application, this insulation may prevent heat transfer to your home.
You will only be able to get 22 BTUs per square foot through the hardwood floors before damaging them.
We would not recommend going smaller than 3/4" PEX if you are tying into your existing zone. 3/4" should work fine.
Yes, you should insulate under the Ultra-Fin plates.
Yes, you can use 180 degree water. The water temperature will be based on the heat load of the room. Please have a look at the manual to determine what water temperature is needed: http://s3.pexsupply.com/manuals/1249544874360/UltraFin_Install_Manual.pdf .
Spacing will be determined by whether you will be using a high temperature or modulating system. Please refer to page four of the installation manual for the correct layout. http://s3.pexsupply.com/manuals/1249544874360/UltraFin_Install_Manual.pdf
The Ultra-fin system uses ½" (5/8" O.D.) tubing.