Apply to be a TradeMaster!
Main product image of Ultra 105 - 81,000 BTU Output High Efficiency Boiler (Nat Gas or LP)
Magnifying glass
Hover image to zoom

Ultra 105 - 81,000 BTU Output High Efficiency Boiler (Nat Gas or LP)

SKU:
383-500-722
Rating:
(19)
Q&A:
(16)
Ultra 105 - 81,000 BTU Output High Efficiency Boiler (Nat Gas or LP)
Magnifying glass
Hover image to zoom
383-500-722 has been discontinued
Discontinued September 7, 2017
This product was discontinued because the part number was changed by the manufacturer. No modifications were made to the replacement product.
Direct Replacement:
Ultra 105 - 81,000 BTU Output High Efficiency Boiler - Series 4 (Nat Gas or LP)
SKU:383-500-734
(19)
VIEW REPLACEMENT
VIEW REPLACEMENT

Product Highlights

Product Highlight: Fuel Type
Natural Gas, Propane
Product Highlight: Vent Type
PVC, Direct Vent, AL29-4C
Product Highlight: Warranty
15 Year Limited (Heat Exchanger), 1 Year (Parts) Warranty
Product Highlight: System Type
Hydronic (Water)
Product Highlight: Width (Inches)
22-13/16" Width
Product Highlight: Color
Slate Gray

Description

Heating equipment must be installed, commissioned, and serviced by a licensed and qualified professional in accordance with manufacturer instructions, applicable codes, and industry standards. Manufacturers do not accept warranty or technical support requests from homeowners or unlicensed individuals. All warranty and technical inquiries must be initiated by the licensed professional responsible for the installation.

Note: Product Title reflects this boiler's IBR Net Output Rating

Easy-up Manifold Installation Options:

Propane Conversion Orifice included for LP Gas Applications
The Ultra Easy-Up Manifold Kit can speed up installation of the primary/secondary piping required on Ultra boilers. Weil-McLain's Easy-Up manifold kit is designed by the boiler manufacturer and provides the added feature of optional indirect water heater connections.

Key Features
  • Gas fired water boiler with cast aluminum heat exchanger
  • Venturi mixing body mixes air and gas providing higher efficiency
  • Designed to operate in low temperature condensing applications
  • Outdoor reset and domestic hot water priority standard
  • Negative regulated gas valve precisely delivers gas to the boiler
  • Electronic control module automatically adjusts blower speed and gas flow rate in response to environment
  • Modulates with 5 to 1 turndown ratio
  • Variable speed motor matches combustion output to heating need
  • High grade stainless steel burner features quiet operation, high efficiency, and cleaner combustion for low NOx applications.

Specs

Width (Inches):

22-13/16"

Fuel Type:

Natural Gas

Propane

Vent Type:

PVC

Direct Vent

AL29-4C

Boiler Type:

High Efficiency

Color:

Slate Gray

Efficiency:

94%

System Type:

Hydronic (Water)

Features:

Direct Vent

EI/Spark Ignition

Condensing

Vent Size:

2"

3"

Water Connection:

1"

Gas Connection:

1/2"

BTU Input:

105000

DOE Rating:

94000

IBR Rating:

81000

Warranty:

15 Year Limited (Heat Exchanger), 1 Year (Parts)

Depth (Inches):

19-15/16"

Height (Inches):

43.0625"

Help Face

Questions?

Speak with a real person who will go out of the way to help!
Call or text 888-757-4774
MondayThursday
8am7:45pm
Friday
9am7:45pm
SaturdaySunday
9am5:45pm


Need help calculating?
Use Our Calculator

Compare Similar Products

Brand
Width (Inches)
Fuel Type
Vent Type
Efficiency
System Type
CURRENT ITEM
Product Image of Ultra 105 - 81,000 BTU Output High Efficiency Boiler (Nat Gas or LP)
Ultra 105 - 81,000 BTU Output High Efficiency Boiler (Nat Gas or LP)
SKU: 383-500-722
(19)
22-13/16"
Natural Gas
Propane
PVC
Direct Vent
AL29-4C
94%
Hydronic (Water)
16-11/16"
Propane
Natural Gas
CPVC
PVC
Direct Vent
95%
Hydronic (Water)
17-1/4"
Natural Gas
Direct Vent
95%
Hydronic (Water)
17-1/4"
Propane
Natural Gas
Direct Vent
95%
Hydronic (Water)

You May Also Need

Box

Ultra 105 CT NG (S3)

Replacement Parts

SKU: 383-500-722

Brand: Weil-McLain

Search Parts:
SEARCH PARTS
Door Gasket Replacement Kit, 383-500-610
383-500-610
Weil-McLain
(1)
Jacket Front Door, 383-500-135
383-500-135
Weil-McLain
(1)
Help Image
Need help finding a replacement part?
Fill out the part request form and someone will get back to you shortly.
PART REQUEST FORM

Product Reviews

4.21 out of 19 reviews
84% would recommend this product
4.21
out of 19 Reviews
84% would recommend this product
WRITE A REVIEW
5 star
68%
4 star
16%
3 star
0%
2 star
0%
1 star
16%
WRITE A REVIEW
Customer Images

Most Liked Positive Review

great product

for basement floor and garage floor it is the best,,, floor heat is the only way to go ,,, love it
VS

Most Liked Negative Review

WeilMcLane 105 Gas Boiler

Residential Use Gas Boiler In the period of 1 year I have had problems that the Weil Mc Lane company has not been able to fix. Last year the boiler went out and after delayed responses and being without the use of the boiler for about 3 weeks the company replaced the unit under warranty. In less then a year the boiler went out again and the contractor has tried several new parts and the company has delayed action to solve the problem for about 1 month.The nights have averaged below 0 with several -10. Very poor support by the company Weil McLane.
Showing 1-10 of 19 reviews

Quality Boiler

I replaced a boiler with the Weil-McLain Ultra modulating boiler. Soooo quiet and extremely efficient.
Boiler Tech
Portland, OR
1 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Expensive, lots of maintance, does not light when cold.

Had trouble with this boiler from the first winter it was installed. When it gets below zero, it will not light. Replaced, blower, gas valve, venture, computer, changed venting. Nothing worked. Works fine in the summer and fall. No good for cold Montana winters. 13 years later, still fighting this boiler. Gets cold and will not light and goes into lockout. I finally installed a damper on the exhaust flue that closes when boiler is not running o trap the heat. Also removed intake vent and use room air for combustion. Seems to be lighting better this fall but we have not had cold weather below zero yet.
D
Montana
2 years ago
Was this review helpful to you?

Ultra 105 S3

Installed In 2013. CO2 Detecter Started going Off In Boiler Room Late Winter 2024. Did Mtc On 9/2/24 And Found A Hole In Back Of Heat Exchanger While Cleaning. Stick With a Cast Iron Boiler. No Headaches No Mtc. Bought All My Parts And Material From Supply House. Always Have Parts And Ships Ssme Or Next Day. Ten Stars For Supply House. One Star Fir The Ultra S3
PCs
Long Island NY
2 years ago
Was this review helpful to you?

I would recommend this boiler

Works great
Frank D
Pennsylvanian
4 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Great product, happy customer

Great efficient, reliable boiler. Like any boiler, they only run as well as they are installed.
Taylor
Burlington, wi
5 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Ultra 105 Boiler

I recently installed one of these boilers that replaced an older cast iron boiler heating system. The boiler fed 3 fin tube zones, a radiant floor zone and an indirect water heater. The installation went very smoothly and the boiler fired right up. The installation was for some friends. They were very impressed with how quiet this boiler operates and how much more hot water they were getting, basically never running out! The instructions that come with this boiler are very thorough and the technical support is first rate. The boiler integrated well with a Taco zone controller.
William
New York
7 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

I would recommend this boiler

Boiler runs great. It would be good if they included the Sentinel water treatment that is required for operation.
Dan H
Pennsylvania
8 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Nice Boiler for the price.

Installation and startup were straightforward. Operation is quiet. The Ultra 105 ships with a Taco 007 boiler pump. Weil Mclain would do well to replace this with one of the new ECM pumps (something like the Grundfos Alpha2. These ECM pumps run at about 25% of the power consumption of the older pumps. I downloaded the installation manual from Weil McLains website prior to ordering the unit. The downloaded manual was out of date and did not reflect the current hardware. I will say the install manual is very well done. Now the temps have dropped the boiler got its first real test today and so far so good.
SunRock
Cincinnati, Ohio
8 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Boiler purchased was a fantastic bargain

Included many items to make installation easy
Andy
Michigan
9 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

This something you won't regreat

I put this boiler in 2 years ago I found that if you service it when your supposed to its at the top of its class. I install all types of boilers there is nothing to compare it
Kevin
Tabernacle new jersey
11 years ago
Was this review helpful to you?

Product Q&A

16 Questions
16 Questions
ASK A QUESTION

Q: with the ultra 105 will i need a seprate water heater for the domestic supply?

Asked by 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Yes, it would need to be connected to an indirect water heater.

Was this review helpful to you?

Q: does it make a lott of noise?

Asked by joe 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

No, this unit is designed to operate quietly.

Was this review helpful to you?

Q: does this unit come with a vent termination kit

Asked by Al 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

No, the kit needs to be purchased separately. It is part number 383-500-350.

Was this review helpful to you?

Q: What size Ultra do I need to heat 1600 square feet?

Asked by 16 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

In order to determine which boiler would be best for you, please try our boiler sizing calculator ( http://www.pexsupply.com/pex/control/BTUCalculator ).

Was this review helpful to you?

Q: Can these units be converted for the use of propane (LP) and what will the manifold pressure be exiting to the burner?

Asked by 05silvermark 16 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Yes, these units can be converted over to LP. A conversion kit, including an alternate orifice, should have came with your unit. The pressure exiting the manifold depends on which gas you are using. Natural gas supply would give you a pressure between 5 w.c-13 w.c (water column = w.c). Liquid Propane supply would give you a pressure between 4 w.c. - 13 w.c.

Was this review helpful to you?

Q: If the input BTU is 105,000 and the output is 81,000 BTU I don't get an efficiency of 95 but 77. What am I doing wrong?

Asked by Electrical EE 16 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

The BTU output of 81,000 is if you are installing the boiler in a place that already does not have heat, such as a shed- which would be your worse case scenario. Most people are installing the boiler in a house which changes the output to around 94,000 which increases that efficiency rating as well. All this information can be found in the product manual which can be viewed below: http://s3.pexsupply.com/manuals/1276634743893/31976_PROD_FILE.pdf

Was this review helpful to you?
- Don The Heating Guy

The lower rating is called IBR (Institute of Boiler & Radiators ) output. It is basically counting for btu losses in uninsulated supply and return piping as well as the radiator or baseboards themselves. In modern radiant tubing installations with low temperature condensing boilers, the DOE number which is much closer to actual input can be used. On forced air furnaces, it would be equivilent to the amount we have to figure in our heat loss studies for duct leakage and poor insulation on the ducts. The boiler manufacturer is basically covering it's tail and making sure you have a little margine for below design day conditions or any other factors they have no control over. I can assure you that the boiler listed here can easily handle a radiant heating system in a house needing 81,000 btu/h by an accurate heat loss study and still have close to 16% spare capacity.

Was this review helpful to you?
- Don The Heating Guy

As a follow up to the answer I gave earlier, the actual efficiency of the boiler is for every 100,000 btu's of gas supplied to boiler, you get 95,000 btu's transfered to the water inside the boiler. It does not take any losses in the rest of the system into account. It is the only thing the boiler manufactuer can control.

Was this review helpful to you?