Copper Crimp Valveless Manifolds are copper water distribution manifolds that split one supply into multiple branch lines without integral shutoff valves. The Sioux Chief 672X0490, for example, has four 1/2" F1807 branches on a 1" Type L copper tube trunk with branches spaced 2 inches on-center. Sioux Chief 672X manifolds such as the 672X0490 and 672X0990 are made of copper (NL/DZR), comply with ASTM F1807, and carry NSF/ANSI/CAN-61 and NSF/ANSI/CAN-372 listings. Sioux Chief lists the unvalved 672X0990 as a great secondary manifold. Port count and trunk connection vary from model to model, so the right pick depends on fixture count and how the supply line arrives. Matching those details to the job keeps the rough-in organized and avoids ordering the wrong configuration for the plumbing layout. Sioux Chief also warns against modifying a manifold, because doing so voids the warranty.
Subcategories
Buying Guide
Start with the supply connection. Confirm whether the trunk inlet needs a 3/4" F1807 connection, as on the Sioux Chief 672X0490, or a male sweat connection, as on the 672X0440 with its 1" male sweat inlet. A mismatch forces extra fittings at the trunk.
Next, count the branches. Total every fixture and appliance the manifold will feed, then choose a port count that covers it. The 672X family is available in 3 to 12 port configurations, and the 672X0690, 672X0830, and 672X0990 offer six, eight, and nine 1/2" F1807 branches with 2 inch on-center spacing.
Check the trunk end. The 672X0440, 672X0490, 672X0690, 672X0830, and 672X0990 all use a closed trunk, so the manifold ends at the last branch instead of passing flow to another run. Sioux Chief instructs installers not to recirculate through any manifold branch, so a branch should never serve as a return.
Decide on valves next. When individual shutoffs are not needed at the manifold, Copper Crimp Valveless Manifolds keep the assembly simple. The 672X0990 has no integral valves, and Sioux Chief calls it a great secondary manifold. Jobs that need branch shutoff call for a valved model instead.
Finally, confirm listings. Sioux Chief 672X models carry NSF/ANSI/CAN-61 and NSF/ANSI/CAN-372 listings and comply with ASTM F1807, which matters for potable water work and local code review. Do not modify the manifold, because Sioux Chief states that doing so voids the warranty.
Frequently Asked Questions
What are copper crimp valveless manifolds used for?
Copper Crimp Valveless Manifolds distribute one water supply to multiple branch lines through a copper trunk. The Sioux Chief 672X0990, for example, has nine 1/2" F1807 branches and no integral valves. Sioux Chief lists it as a great secondary manifold.
Can I recirculate through a branch on a valveless copper manifold?
Sioux Chief instructs installers not to recirculate through any manifold branch on its 672X copper manifolds. Copper crimp valveless manifolds are built for distribution, so a return line should connect elsewhere in the system.
What inlet options do valveless copper manifolds have?
Copper crimp valveless manifolds in the Sioux Chief 672X line come with different inlets. The 672X0490 has a 3/4" F1807 inlet, the 672X0440 has a 1" male sweat inlet, and the 672X0830 has a 3/4" male sweat inlet. Each of those models uses a closed trunk.
How far apart are the branches on these manifolds?
Copper crimp valveless manifolds such as the Sioux Chief 672X0440, 672X0490, 672X0830, and 672X0990 space their 1/2" F1807 branches 2 inches on-center. The spacing matters when planning the mounting area for the manifold.
Are valveless copper manifolds lead-free and listed for potable water?
Copper crimp valveless manifolds like the Sioux Chief 672X0690 and 672X0990 are lead-free certified under IAPMO RT NSF 61 and carry NSF/ANSI/CAN-61 and NSF/ANSI/CAN-372 listings. Verify the listing on the specific model before specifying it for a project.