Apply to be a TradeMaster!
Filter menu expanded

Filters

1,221 items
Reset

SORT

Product Availability
–

Show In Stock Only (593)

Amperage
–

2.5 (2)
3 (2)
5 (4)
6 (2)
7 (5)
9 (29)
10 (17)
12 (21)
15 (3)
17 (1)

Voltage
–

12v (1)
12-250 V (1)
24 VAC (4)
24 VDC (4)
24-240V AC/DC (1)
24V (183)
36V (1)
50-129V AC/DC (1)
100V (1)
110v (69)

Poles
–

1 (77)
1.5 (15)
2 (161)
3 (475)
4 (53)
5 (1)
6 (6)
8 (5)
10 (2)
12 (2)

Review Score
–

(97)
(8)
(3)
(2)

Price Range
–

$5 to $10 (11)
$10 to $15 (50)
$15 to $20 (46)
$20 to $25 (52)
$25 to $30 (41)
$30 to $35 (61)
$35 to $40 (78)
$40 to $45 (51)
$45 to $50 (27)
$50 to $60 (69)

Electrical Contactors

Help Face
Need a little help?
1221 items
Grid
List
Compare
Product Image of 1-1/2 Pole Definite Purpose Contactor (30A, 240V)
$14.73 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 3-Pole NEMA Non-Reversing Motor Control Contactor, Full Voltage, Size 2 (120/110V, 45 Amp)
$1,412.18 each
In Stock
Get 1 by Tomorrow, Oct 1
In Stock
Get 1 by Tomorrow, Oct 1
Compare
Product Image of Contactor Auxiliary Contact Block For TeSys D And TeSys F, LADN01
Contactor Auxiliary Contact Block For TeSys D And TeSys F, LADN01
SKU: LADN01
Schneider Electric
SKU: LADN01
$16.76 each
In Stock
Get 19 by Mon, Oct 5 - Tue, Oct 6
In Stock
Get 19 by Mon, Oct 5 - Tue, Oct 6
Compare
Product Image of Contact Block, 1N/C (22 mm, Front Plate Mounting, 10A, 500V AC/DC)
Contact Block, 1N/C (22 mm, Front Plate Mounting, 10A, 500V AC/DC)
SKU: 3SU1400-1AA10-1CA0
Siemens
SKU: 3SU1400-1AA10-1CA0
Brand: Siemens
(1)
$17.58 each
In Stock
Get 4 by Mon, Oct 5
In Stock
Get 4 by Mon, Oct 5
Compare
Product Image of 3-Pole Non-Reversing Contactor (120V, 32 Amp)
3-Pole Non-Reversing Contactor (120V, 32 Amp)
SKU: XTCE032C10A
Eaton
SKU: XTCE032C10A
Brand: Eaton
$255.96 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 780 Series 2 Pole Definite Purpose Contractor w/ Quick Connect & Screw Type Termination (30A, 24V)
$31.81 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 100-250v 60hz Contactor, Af52-30-11-13
100-250v 60hz Contactor, Af52-30-11-13
SKU: AF52-30-11-13
ABB
SKU: AF52-30-11-13
Brand: ABB
$198.92 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 3 Pole N/C Non-Reversing Mini TeSys K Contactor, 9A (110V)
$100.68 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of No Enclosure, 3 Pole, Electrically Held Lighting Contactor 30 A (Tungsten), 110 VAC at 50 Hz, 120 VAC at 60 Hz, 8903SMO2V02
$450.03 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 3 Pole Definite Purpose Contactor (30A, 240V)
$29.42 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of Replacement Contact Kit for 3RT1054
Replacement Contact Kit for 3RT1054
SKU: 3RT1954-6A
Siemens
SKU: 3RT1954-6A
Brand: Siemens
$791.49 each
In Stock
Get 1 by Fri, Oct 2
In Stock
Get 1 by Fri, Oct 2
Compare
Product Image of 3 Pole Easy TeSys DPE IEC Contactor (5HP, 12A, 24 VAC, 480V)
$29.25 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of Jard 2 Pole Definite Purpose Contactor w/ Lugs (30A, 240V)
$24.04 each
In Stock
Get 4 by Mon, Oct 5
In Stock
Get 4 by Mon, Oct 5
Compare
Product Image of 3-Pole Definite Purpose Contactor (110/120V, 75 Amp)
3-Pole Definite Purpose Contactor (110/120V, 75 Amp)
SKU: C25FNF375A
Eaton
SKU: C25FNF375A
Brand: Eaton
$434.95 each
In Stock
Get 4 by Tomorrow, Oct 1
In Stock
Get 4 by Tomorrow, Oct 1
Compare
Product Image of 3-Pole XT IEC Non-Reversing Contactor, Full Voltage, Size E (110/120V, 25 Amp)
$599.70 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 24V-500Vac Contactor Non Rever, AF116-30-00-11
24V-500Vac Contactor Non Rever, AF116-30-00-11
SKU: AF116-30-00-11
ABB
SKU: AF116-30-00-11
Brand: ABB
$554.37 each
In Stock
Get 1 by Fri, Oct 2
In Stock
Get 1 by Fri, Oct 2
Compare
Product Image of Aux Contact 1 No/1 Nc, Cal19-11
Aux Contact 1 No/1 Nc, Cal19-11
SKU: CAL19-11
ABB
SKU: CAL19-11
Brand: ABB
$35.78 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of Contactor Thermal Unit For B Series, B8.20
$46.27 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 3 Pole, 38 Amp, 1NO/1NC, 220V Power Contactor
3 Pole, 38 Amp, 1NO/1NC, 220V Power Contactor
SKU: 3RT2028-1AN20
Siemens
SKU: 3RT2028-1AN20
Brand: Siemens
$309.54 each
In Stock
Get 4 by Fri, Oct 2
In Stock
Get 4 by Fri, Oct 2
Compare
Product Image of Auxiliary Switch for Titan Max Contactor 2NC
$16.90 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 2NC Contactor Auxiliary Contact Block For TeSys K, LA1KN02
$15.81 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 3 Pole Contactor w/ Box Lug Termination (90A, 120V)
$467.80 each
In Stock
Get 5 by Tomorrow, Oct 1
In Stock
Get 5 by Tomorrow, Oct 1
Compare
Product Image of 3 Pole, 110–120/220–240V, 3 Phase Non-Reversing Contactor w/ Switch (45A)
$788.91 each
In Stock
Get 2 by Fri, Oct 2
In Stock
Get 2 by Fri, Oct 2
Compare
Product Image of 3-Pole Contactor (24V, 40 Amp)
3-Pole Contactor (24V, 40 Amp)
SKU: XTCE040D00T
Eaton
SKU: XTCE040D00T
Brand: Eaton
$392.75 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 3 Pole Contactor, NO 200 to 208Vac at 50/60 Hz, TeSys K, LC1K0910L7
$91.14 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of Contact Repair Kit, Nema 2
Contact Repair Kit, Nema 2
SKU: 75FP14
Siemens
SKU: 75FP14
Brand: Siemens
$239.22 each
In Stock
Get 1 by Fri, Oct 2
In Stock
Get 1 by Fri, Oct 2
Compare
Product Image of 2 Nc Auxiliary Contact Block, Ve5-2
2 Nc Auxiliary Contact Block, Ve5-2
SKU: VE5-2
ABB
SKU: VE5-2
Brand: ABB
$75.15 each
In Stock
Get 1 by Fri, Oct 2
In Stock
Get 1 by Fri, Oct 2
Compare
Product Image of 40 to 65 Amp, Contactor Coil for LC1D40A-D65A, LC1DT60A, LC1DT80A and TeSys D, LXD3U7
$56.85 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 3 Pole, 65 Amp, 1NO/1NC, 110/120V Power Contactor
3 Pole, 65 Amp, 1NO/1NC, 110/120V Power Contactor
SKU: 3RT2037-1AK60
Siemens
SKU: 3RT2037-1AK60
Brand: Siemens
$438.20 each
In Stock
Get 3 by Fri, Oct 2
In Stock
Get 3 by Fri, Oct 2
Compare
Product Image of 3 Pole, 25 Amp, 1NO/1NC, 50 Hz, 24V Power Contactor
3 Pole, 25 Amp, 1NO/1NC, 50 Hz, 24V Power Contactor
SKU: 3RT2026-1AB00
Siemens
SKU: 3RT2026-1AB00
Brand: Siemens
$191.86 each
In Stock
Get 1 by Fri, Oct 2
In Stock
Get 1 by Fri, Oct 2
Compare
Product Image of Contactor 3p 24-60vac, Af38-30-00-11
Contactor 3p 24-60vac, Af38-30-00-11
SKU: AF38-30-00-11
ABB
SKU: AF38-30-00-11
Brand: ABB
$179.04 each
In Stock
Get 1 by Fri, Oct 2
In Stock
Get 1 by Fri, Oct 2
Compare
Product Image of Contactor Thermal Unit, A16.2
Contactor Thermal Unit, A16.2
SKU: A16.2
Square D
SKU: A16.2
Brand: Square D
$32.82 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 100-250v 50/60hz Dc Contactor, Af16-30-01-13
100-250v 50/60hz Dc Contactor, Af16-30-01-13
SKU: AF16-30-01-13
ABB
SKU: AF16-30-01-13
Brand: ABB
$139.24 each
In Stock
Get 2 by Fri, Oct 2
In Stock
Get 2 by Fri, Oct 2
Compare
Product Image of Class 42 DP 50A 3-Pole Definite Purpose Contactor, 24V Coil, Open Type
$281.55 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of Contact Repair Kit, NEMA Sz 1
Contact Repair Kit, NEMA Sz 1
SKU: 75DF14
Siemens
SKU: 75DF14
Brand: Siemens
$143.03 each
In Stock
Get 5 by Fri, Oct 2
In Stock
Get 5 by Fri, Oct 2
Compare
Product Image of 32 Amp 3-Pole NC & NO 220VAC 50/60 Hz IEC Contactor, LC1D32M7
$285.33 each
In Stock
Get 1 by Mon, Oct 5 - Tue, Oct 6
In Stock
Get 1 by Mon, Oct 5 - Tue, Oct 6
Compare
Product Image of 3 Pole 100-250vac-vdc Contactor, Af80-30-11-13
3 Pole 100-250vac-vdc Contactor, Af80-30-11-13
SKU: AF80-30-11-13
ABB
SKU: AF80-30-11-13
Brand: ABB
$444.26 each
In Stock
Get 4 by Fri, Oct 2
In Stock
Get 4 by Fri, Oct 2
Compare
Product Image of 1-1/2 Pole Definite Purpose Contactor w/ Screw Termination, A2L Compliant (30A, 120V)
$22.78 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of Contactor Thermal Unit For B Series, B11.5
$41.48 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 24vac 3p No Contactor, Af80-30-00-11
24vac 3p No Contactor, Af80-30-00-11
SKU: AF80-30-00-11
ABB
SKU: AF80-30-00-11
Brand: ABB
$454.20 each
In Stock
Get 1 by Fri, Oct 2
In Stock
Get 1 by Fri, Oct 2
Compare
Product Image of 1 Pole Contactor (220V, 32 Amp)
1 Pole Contactor (220V, 32 Amp)
SKU: RS-3210M7-220V
Robertshaw
SKU: RS-3210M7-220V
Brand: Robertshaw
$13.96 each
In Stock
Get 4 by Tomorrow, Oct 1
In Stock
Get 4 by Tomorrow, Oct 1
Compare
Product Image of 3 Pole, 40 Amp, 200/220V Power Contactor
3 Pole, 40 Amp, 200/220V Power Contactor
SKU: 3RT1035-1AN60-1AA0
Siemens
SKU: 3RT1035-1AN60-1AA0
Brand: Siemens
$229.89 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 1 Pole Contactor (24V, 32 Amp)
1 Pole Contactor (24V, 32 Amp)
SKU: RS-3210M7-24V
Robertshaw
SKU: RS-3210M7-24V
Brand: Robertshaw
$13.96 each
In Stock
Get 4 by Tomorrow, Oct 1
In Stock
Get 4 by Tomorrow, Oct 1
Compare
Product Image of 3 Pole, 40 Amp, 220/240V Power Contactor
3 Pole, 40 Amp, 220/240V Power Contactor
SKU: 3RT1035-1AP60
Siemens
SKU: 3RT1035-1AP60
Brand: Siemens
$204.48 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 3 Pole, 7 Amp, 24V Power Contactor
3 Pole, 7 Amp, 24V Power Contactor
SKU: 3RT20151AB01
Siemens
SKU: 3RT20151AB01
Brand: Siemens
$91.28 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of Contactor Suppressor Module for LC1D400-D650, LC1D80-D150, LP1D400-D650 and TeSys D, LA4DA2U
$34.13 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of N/C Aux Contact Kit
N/C Aux Contact Kit
SKU: 49AB01
Siemens
SKU: 49AB01
Brand: Siemens
$127.61 each
In Stock
Get 1 by Fri, Oct 2
In Stock
Get 1 by Fri, Oct 2
Compare
Product Image of Contactor 3 Pole 190 Amp 1 No/nc, Af190-30-11-13
Contactor 3 Pole 190 Amp 1 No/nc, Af190-30-11-13
SKU: AF190-30-11-13
ABB
SKU: AF190-30-11-13
Brand: ABB
$1,057.02 each
In Stock
Get 1 by Fri, Oct 2
In Stock
Get 1 by Fri, Oct 2
Resources
FAQs, Manuals & Videos
Articles
More About Contactors

Contactors are electromechanical switches that use a low-voltage control signal to open and close a higher-voltage power circuit, most commonly the circuit that feeds a compressor, condenser fan motor, or other large HVAC or electrical load. A thermostat or control board sends a small signal to energize the contactor's coil, which pulls a set of contacts together and completes the high-voltage circuit without routing that heavier current through the control wiring itself. HVAC technicians replace contactors more often than almost any other electrical component in a split system, since the contacts see repeated arcing every time the compressor or fan cycles on and off. A pitted, burned, or stuck contactor is a common cause of equipment that will not start, that hums without running, or that keeps running after the thermostat is satisfied. Contactors are sized by coil voltage, number of poles, and current rating, and matching all three to the application is what keeps a replacement working safely in place of the original.

Subcategories

  • Single-Pole Contactors: Single-pole contactors switch one leg of the power circuit while the other leg stays connected directly, a configuration common on smaller residential condensing units and single-phase loads. They cost less and take up less panel space than multi-pole versions, which makes them a common original-equipment choice on lighter-duty equipment. Technicians confirm the coil voltage and current rating match the original part before swapping one in, since an undersized contactor will fail quickly under the same load. Single-pole units are typically the most frequently replaced contactor type on residential service calls.
  • Double-Pole and Two-Pole Contactors: Double-pole contactors switch both legs of a two-wire power circuit simultaneously, fully disconnecting the load rather than leaving one leg energized. This configuration is common on larger residential and light commercial condensing units where fully isolating the compressor circuit is the standard design approach. Replacing a double-pole contactor with a single-pole unit is not a safe substitution even if the coil voltage matches, since the circuit design depends on both legs switching together. Technicians check the original wiring diagram when the pole configuration is not obvious from the failed part alone.
  • Three-Pole Contactors: Three-pole contactors switch all three legs of a three-phase power circuit, a configuration used almost exclusively on commercial and light industrial HVAC equipment rather than typical residential split systems. Failure symptoms mirror single and double-pole units, including pitted contacts, a stuck armature, or a coil that no longer pulls in reliably. Because three-phase equipment often carries higher current loads, three-pole contactors are built with heavier contact material to handle the added electrical stress. Matching current rating and coil voltage remains the deciding factor when selecting a replacement, the same as with lower pole-count contactors.
  • Definite Purpose Contactors: Definite purpose contactors are built specifically for a narrow range of applications, most often HVAC compressor and fan loads, rather than the broader industrial control uses that a general-purpose contactor covers. Their compact size and simplified mounting make them the standard choice for residential and light commercial condensing unit replacement work. Technicians stock definite purpose contactors in the most common voltage and pole configurations since these cover the large majority of service calls. Choosing a definite purpose model built for the specific application avoids paying for features meant for industrial control panels that a condensing unit will never use.

Buying Guide

Matching a replacement contactor to the failed original starts with three specifications: coil voltage, number of poles, and full-load or resistive current rating. Coil voltage refers to the low-voltage signal that energizes the contactor, commonly a value supplied by the control transformer, and it needs to match exactly since a contactor with the wrong coil voltage either will not pull in or will burn out quickly from overvoltage. Pole count determines how many legs of the power circuit the contactor switches, and current rating determines how much load the contacts can handle without excessive arcing or premature failure.

Physical size and terminal configuration matter for a clean installation, since Contactors mount inside a tight electrical compartment where a slightly larger or differently shaped replacement may not fit the existing bracket or wiring layout without modification. Comparing the physical footprint of a proposed replacement against the failed part before ordering avoids a return trip when the new contactor does not clear the panel enclosure.

Technicians working service routes across a mix of residential and light commercial equipment generally keep the most common single-pole and double-pole configurations on the truck, since these cover the majority of everyday calls. Three-pole contactors and less common voltage combinations are usually ordered once the specific unit's requirements are confirmed on site rather than stocked in bulk, since commercial three-phase equipment makes up a smaller share of most residential-focused service work.

Frequently Asked Questions

What are the signs that a contactor needs to be replaced?

A unit that hums but will not start, a compressor or fan that keeps running after the thermostat is satisfied, or visible pitting and burn marks on the contacts all point toward a failing contactor. A contactor that chatters or buzzes audibly when energized is also a common warning sign. Testing the coil for continuity and checking the contacts for excessive wear confirms the diagnosis before ordering a replacement.

How is coil voltage different from the contactor's power circuit voltage?

Coil voltage is the low-voltage signal, typically supplied through the control transformer, that energizes the contactor and pulls the contacts together. The power circuit voltage is the separate, usually much higher, voltage that the contacts switch on and off to run the compressor or fan motor. Both values need to be checked separately since matching one without the other will not produce a working replacement.

Can a single-pole contactor be replaced with a double-pole model?

A double-pole contactor can generally replace a single-pole unit as long as coil voltage and current rating match, since the extra pole simply switches the additional leg without disconnecting anything unusual. The reverse substitution, replacing a double-pole contactor with a single-pole unit, is not safe since it leaves one leg of the circuit energized when it should be fully disconnected. Checking the original wiring diagram before making the swap avoids this mistake.

Why do HVAC contactors fail more often than other electrical components?

Contactors switch a large electrical load every time the compressor or fan cycles on and off, and that repeated arcing gradually wears down the contact material until the connection becomes unreliable. Units that cycle frequently, such as during a hot summer with heavy air conditioning use, put more cumulative wear on the contactor than equipment that runs for longer, less frequent cycles. This wear pattern makes contactors one of the most commonly replaced parts in HVAC service work.

Is it safe to bypass a failed contactor temporarily?

Bypassing a contactor removes the low-voltage control point that allows the thermostat to safely start and stop the compressor or fan, which creates both a safety hazard and a risk of equipment damage from uncontrolled operation. A temporary bypass is not a substitute for a proper repair and should not be left in place beyond diagnosing the fault. Replacing the failed contactor with a correctly matched part is the only reliable fix.