Fab 5 Fabriflex Low Pressure Ducting is flexible air duct made from reinforced aluminized trilaminate, mechanically locked together by a corrosion-resistant galvanized steel helix. The non-insulated Fab 5 is a UL-181 Class 1 and ULC-S110 product. It's formed as a low to medium pressure duct, the type often required by VAV commercially designed air conditioning and heating applications. The family also includes insulated constructions, the Fab 5-T and the Fab 5-M, so the same duct style can serve runs that need thermal protection as well as runs that don't. Duct selection touches code compliance, energy performance, and install time all at once. Knowing how each version is built helps estimators, installers, and engineers pick the right duct before material is ordered, which keeps submittals clean and cuts the risk of swapping product on site.
Subcategories
Buying Guide
Start with the job spec. If the drawings call for UL-181 Class 1 flexible duct, confirm the exact version carries that listing before anything else. The manufacturer lists the non-insulated Fab 5 and the Fab 5-M as UL-181 Class 1 and ULC-S110 products, while its Fab 5-T page lists UL-181 Class 1 only. When a project calls for ULC-S110, verify that version against the manufacturer's published data first.
Next, decide on insulation. Non-insulated Fab 5 suits runs where insulation is handled separately or isn't required. Insulated versions include thermal protection as part of the duct. Between the two insulated options, the Fab 5-T uses a polyethylene vapor barrier and the Fab 5-M uses a mylar sleeve, so match the covering to the conditions on the job.
Then check the pressure class. Fab 5 Fabriflex Low Pressure Ducting is built for low to medium pressure duct, so compare the system's design static pressure with the manufacturer's published ratings for the diameter being ordered. Catch a mismatch before the order is placed, not after the duct is hung.
Finally, match diameter and length to the layout, and order connectors, clamps, and sealing materials with the duct so the crew isn't waiting on parts. Record exact part numbers on the submittal so the engineer and inspector review the same product the crew installs.
Frequently Asked Questions
What is Fab 5 Fabriflex duct made of?
Fab 5 Fabriflex Low Pressure Ducting is made of reinforced aluminized trilaminate. The layers are mechanically locked together by a corrosion-resistant galvanized steel helix. The manufacturer describes the construction as a low to medium pressure duct.
Is Fab 5 flexible duct UL-181 Class 1 listed?
Fab 5 Fabriflex duct is listed by the manufacturer as a UL-181 Class 1 product. The non-insulated Fab 5 and the Fab 5-M are also listed as ULC-S110 products. The Fab 5-T page lists UL-181 Class 1, so check the manufacturer's data if ULC-S110 is required on that version.
What's the difference between Fab 5-T and Fab 5-M?
Both insulated Fab 5 versions use the reinforced aluminized trilaminate and galvanized steel helix construction with thick fiberglass insulation. The Fab 5-T uses GREENGUARD certified JM Formaldehyde-free insulation covered by a flame retardant, non-toxic polyethylene vapor barrier. The Fab 5-M is built with fiberglass insulation and a mylar sleeve.
Where do contractors use Fab 5 Fabriflex duct?
Fab 5 Fabriflex Low Pressure Ducting is a low to medium pressure duct, and the manufacturer notes that this type of duct is often required by VAV commercially designed air conditioning and heating applications. The manufacturer describes the insulated Fab 5-M assembly as ideal for energy efficient HVAC installations. Check the project spec for the required pressure class and listings before choosing a version.
Does Fab 5 flexible duct come insulated?
The Fab 5 line from the manufacturer includes a non-insulated Fab 5 and insulated Fab 5-T and Fab 5-M versions. Fab 5-T uses fiberglass insulation with a polyethylene vapor barrier, and Fab 5-M uses fiberglass insulation with a mylar sleeve. Pick the version that matches the insulation requirement on the job.