Apply to be a TradeMaster!
Filter menu expanded

Filters

68 items
Reset

SORT

Product Availability

Show In Stock Only (55)

Used With

42 Series (1)
42S Series (1)
47 Series (2)
61 Series (3)
63-BM (1)
63-M (1)
64 Series (4)
67 Series (5)
67-G (1)
69 Series (4)

Review Score

(25)
(1)
(1)

Price Range

$5 to $10 (2)
$10 to $15 (5)
$15 to $20 (1)
$30 to $35 (1)
$45 to $50 (1)
$50 to $60 (2)
$60 to $70 (2)
$70 to $80 (2)
$90 to $100 (1)
$100 to $200 (6)

Mcdonnell & Miller Low Water Cutoff Replacement Parts

Help Face
Need a little help?
68 items
Grid
List
Compare
Product Image of E-11M-24V Manual Reset Switch
E-11M-24V Manual Reset Switch
SKU: 354001
McDonnell & Miller
SKU: 354001
$351.77 each
In Stock
Get 3 by Tomorrow, Aug 19
In Stock
Get 3 by Tomorrow, Aug 19
Compare
Product Image of 69-113, O-Ring for 69
69-113, O-Ring for 69
SKU: 318826
McDonnell & Miller
SKU: 318826
$10.48 each
In Stock
Get 2 by Thu, Aug 20
In Stock
Get 2 by Thu, Aug 20
Compare
Product Image of SA64-30, Float Assembly for 64
$248.69 each
In Stock
Get 3 by Thu, Aug 20
In Stock
Get 3 by Thu, Aug 20
Compare
Product Image of Test-N-Check Lower Valve (TC-L)
$481.99 each
Backorder
Get it by Thu, Sep 17 - Thu, Oct 15
Backorder
Get it by Thu, Sep 17 - Thu, Oct 15
Compare
Product Image of MA559 Quick Hook-Up Fittings for 67 Series
$231.00 each
Backorder
Get it by Thu, Sep 17 - Thu, Oct 15
Backorder
Get it by Thu, Sep 17 - Thu, Oct 15
Compare
Product Image of 69-114, O-Ring for 69
$11.69 each
In Stock
Get 4 by Thu, Aug 20
In Stock
Get 4 by Thu, Aug 20
Compare
Product Image of SA63-5, Bellows Assembly for 63 Series
$570.47 each
In Stock
Get 2 by Thu, Aug 20
In Stock
Get 2 by Thu, Aug 20
Compare
Product Image of UWH-RB-24-S, Replacement Wiring Harness for RB-24E-S
$59.50 each
Backorder
Get it by Thu, Sep 17 - Thu, Oct 15
Backorder
Get it by Thu, Sep 17 - Thu, Oct 15
Compare
Product Image of SA63-30, Float Assembly w/ Gasket for 63 Series
$140.70 each
In Stock
Get 7 by Thu, Aug 20
In Stock
Get 7 by Thu, Aug 20
Compare
Product Image of 7-BM Manual Reset Proportioning Switch
$1,868.07 each
Backorder
Get it by Thu, Sep 17 - Thu, Oct 15
Backorder
Get it by Thu, Sep 17 - Thu, Oct 15
Compare
Product Image of Series 93, Low Water Cut-Off/Pump Controller - Snap Acting Switch
$2,416.44 each
In Stock
Get 5 by Thu, Aug 20
In Stock
Get 5 by Thu, Aug 20
Compare
Product Image of 48" G-4-SS Non-Teflon Ground Probe
$56.34 each
Backorder
Get it by Thu, Sep 17 - Thu, Oct 15
Backorder
Get it by Thu, Sep 17 - Thu, Oct 15
Compare
Product Image of 159S-HD, Head Assembly for Combination Low Water Cutoff & Pump Controller w/ 2 SPST switches
$1,437.36 each
In Stock
Get 3 by Thu, Aug 20
In Stock
Get 3 by Thu, Aug 20
Compare
Product Image of 72" G-6-Ss Non-Teflon Ground Probe
$72.62 each
Backorder
Get it by Thu, Sep 17 - Thu, Oct 15
Backorder
Get it by Thu, Sep 17 - Thu, Oct 15
Compare
Product Image of 158S-HD, Head Assembly for 158S Low Water Cutoff
$1,305.17 each
Backorder
Get it by Thu, Sep 17 - Thu, Oct 15
Backorder
Get it by Thu, Sep 17 - Thu, Oct 15
Compare
Product Image of 60" G-5-SS Non-Teflon Ground Probe
$71.38 each
Backorder
Get it by Thu, Sep 17 - Thu, Oct 15
Backorder
Get it by Thu, Sep 17 - Thu, Oct 15
Compare
Product Image of 158S-M-MD-HD, Head Assembly for 158S Low Water Cutoff, w/ Manual Reset, w/ Maximum Differential
$1,289.38 each
Backorder
Get it by Thu, Sep 17 - Thu, Oct 15
Backorder
Get it by Thu, Sep 17 - Thu, Oct 15
Compare
Product Image of 93-M-HD, Head Mechanism for 93 & 193 Series Combination Low Water Cutoff/Pump Controllers
$2,255.00 each
In Stock
Get 1 by Tomorrow, Aug 19
In Stock
Get 1 by Tomorrow, Aug 19
Compare
Product Image of 158S-M-HD, Head Assembly for 158S Low Water Cutoff, w/ Manual Reset
$1,295.50 each
Backorder
Get it by Thu, Sep 17 - Thu, Oct 15
Backorder
Get it by Thu, Sep 17 - Thu, Oct 15
Compare
Product Image of 157R158S-HD, Head Replacement for Low Water Cutoff
$2,034.17 each
Backorder
Get it by Thu, Sep 17 - Thu, Oct 15
Backorder
Get it by Thu, Sep 17 - Thu, Oct 15
Resources
FAQs, Manuals & Videos
Articles
More About Mcdonnell & Miller Low Water Cutoff Replacement Parts

Mcdonnell & Miller low water cutoff replacement parts keep a boiler's most important safety control working correctly after the original float, probe, or gasket wears out. A low water cutoff shuts down the burner or ignition system when water level inside the boiler drops below a safe operating point, protecting the heat exchanger from the damage that dry-firing causes. Mcdonnell & Miller has supplied these controls to the hydronic heating trade for decades, and both its mechanical float and electronic probe designs remain standard equipment on residential and commercial boilers alike. This category covers the individual components a low water cutoff is built from, including float assemblies, probes, gaskets, and switch mechanisms sized to specific Mcdonnell & Miller models. Replacing a single worn part restores full function without the cost of swapping the entire control. Because a low water cutoff is a life-safety device, matching the exact model and mounting pattern matters more here than on most other boiler components.

Subcategories

  • Float Assemblies: Float assemblies are the moving mechanical component inside a traditional float-style low water cutoff, rising and falling with the water level to trip the switch. Boiler technicians replace them when a float becomes waterlogged, corroded, or sluggish, since a slow-moving float can delay shutdown. Matching the exact float diameter and arm length to the original model keeps the trip point accurate. A pitted or heavily scaled float is often the first sign that the whole chamber needs cleaning too.
  • Probes and Sensors: Probes and sensors serve the same safety function as a float but use an electronic conductivity or infrared signal to detect water level instead of a moving part. Technicians favor probe-style cutoffs on systems where sediment or debris could jam a mechanical float. Replacement probes must match the control module's voltage and sensing method exactly, since mixing components from different control generations can produce false trips or no trip at all.
  • Gaskets and Seals: Gaskets and seals stop water from leaking past the cutoff's mounting flange or inspection cover, and they harden or compress over years of heat cycling. A technician doing routine boiler maintenance often replaces the gasket as a matter of course whenever the cutoff housing is opened for cleaning or float inspection. Using the correct gasket thickness keeps the float chamber sealed without over-compressing and cracking the housing.
  • Switches and Relays: Switches and relays are the electrical components that translate the float or probe's position into a signal that shuts down the burner circuit. These parts wear from repeated electrical cycling long before the mechanical float itself fails. A sticking or corroded switch contact can leave a boiler either nuisance-tripping or, worse, failing to cut off power when water runs low, which is why technicians test switch continuity as part of any low water cutoff service call.

Buying Guide

Start by identifying the exact Mcdonnell & Miller model number stamped on the cutoff housing before ordering any replacement part, since float sizes, probe types, and mounting patterns have changed across product generations. A part that looks similar but doesn't match the original model can fail to seat correctly or, worse, fail to trip the burner circuit when water level drops.

Next, decide whether the job calls for a single component repair or a full control replacement. A cutoff with a corroded float chamber, cracked housing, or repeated switch failures is often more cost-effective to replace outright than to keep repairing piece by piece. When browsing Mcdonnell & Miller low water cutoff replacement parts, contractors servicing older cast-iron boilers should pay close attention to thread size and pipe connection style, since older installations sometimes use fittings that newer replacement kits don't include.

Because this is a safety device tied to fire and scald protection, never substitute a generic float switch or aftermarket probe unless it's explicitly rated as a direct replacement for the specific Mcdonnell & Miller model in service. After installation, test the cutoff by draining water below the trip point and confirming the burner shuts down, rather than assuming a new part is functioning correctly based on appearance alone. Keeping a small stock of the most common float and gasket sizes for the boiler models serviced most often shortens a routine maintenance call considerably.

Frequently Asked Questions

How often should a low water cutoff be tested?

Most manufacturers and boiler manuals recommend testing a low water cutoff at the start of every heating season and again partway through, since sediment buildup during the off-season is a common cause of a sluggish or stuck float. Commercial boilers often follow a more frequent schedule set by local code or insurance requirements.

Can a probe-style cutoff replace a float-style unit on the same boiler?

Only if the mounting pattern, tapping size, and control voltage all match, since the two designs sense water level differently and use different wiring. In most cases swapping designs means replacing the entire control rather than just the sensing element.

What does it mean when a low water cutoff keeps tripping even with adequate water?

A nuisance trip usually points to a sticking float, a fouled probe, or sediment inside the chamber rather than an actual water shortage. Cleaning the chamber and testing float or probe movement by hand typically resolves it, but a switch that continues tripping after cleaning should be replaced.

Do these parts work on both steam and hot water boilers?

Mcdonnell & Miller makes low water cutoff models for both steam and hydronic hot water systems, but the internal float and probe designs differ between the two. Confirming the boiler type before ordering parts avoids mismatched components.

Is a low water cutoff required by code on residential boilers?

Requirements vary by state and municipality, but many jurisdictions mandate a working low water cutoff on any boiler, residential or commercial. Checking local plumbing and heating code before removing or bypassing one is standard practice, since it's a life-safety device.

Didn't find what you're looking for? 
Let us know
.