Apply to be a TradeMaster!
Filter menu expanded

Filters

285 items
Reset

SORT

Product Availability
–

Show In Stock Only (139)

Brand
–

ABB (20)
Eaton (21)
Embraco (39)
Schneider Electric (81)
Siemens (50)
Square D (72)
Supco (2)

Voltage
–

110v (2)
120v (1)
220v (2)
115V (2)
24 VAC (1)
24 VAC/VDC (1)
480V (1)
575v (1)
600 VAC (13)
600V (1)

Amperage
–

4.6 (1)
10 (8)
16 (2)
18 (5)
30 (2)
32 (10)
0.16 (1)
0.25 (1)
0.4 (2)
0.63 (1)

Review Score
–

(10)
(1)

Price Range
–

$10 to $15 (4)
$15 to $20 (8)
$20 to $25 (12)
$25 to $30 (9)
$30 to $35 (5)
$35 to $40 (32)
$45 to $50 (2)
$50 to $60 (4)
$60 to $70 (5)
$70 to $80 (15)

Overload Relays

Help Face
Need a little help?
285 items
Grid
List
Compare
Product Image of Indicator
Indicator
SKU: 2810-C4-X2
Square D
SKU: 2810-C4-X2
Brand: Square D
$13.72 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Solid State Overload Relay, Manual Auto Reset, 12.5-50 Amp
$348.57 each
Out of Stock
Get it by Tue, Dec 8 - Tue, Dec 15
Out of Stock
Get it by Tue, Dec 8 - Tue, Dec 15
Compare
Product Image of Overload Relay, Manual Auto Reset, Size S00, Class 10, 1.8-2.5 Amp
$51.76 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Stand-Alone Assembly Support for 3RU21/3RB30/3RB31/3RR2 Size S2 Overload Relays
$37.83 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of NEMA Size 3 Melting Alloy Replacement Overload Relay (600VAC), 9065SDO12
$292.99 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of NEMA Size 2 Motor Logic Solid State Overload Relay, Separate Mount (15-45A, 600VAC), 9065SF220
$353.13 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of NEMA Size 3 Motor Logic Solid State Overload Relay, Replacement (30-90A, 600VAC), 9065ST320
$401.00 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of NEMA Size 3 Motor Logic Solid State Overload Relay, Separate Mount (30-90A, 600VAC), 9065SF320
$430.05 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of NEMA Size 0 Melting Alloy Replacement Overload Relay (600VAC), 9065SDO5
$176.09 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of NEMA Size 2 Melting Alloy Separate Mount Overload Relay (600VAC), 9065SEO8
$210.26 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of NEMA Size 4 Motor Logic Solid State Overload Relay, Separate Mount (45-135A, 600VAC), 9065SF420
$643.17 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Easy TeSys DPER Thermal Overload Relay (0.16 - 0.25A, Class 10)
$26.89 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 3NO/NC 24 VDC Control Relay, CA3KN31BD3
$178.30 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Contactor Lug For CR1F400 And LC1F400, DZ2FJ1
$17.74 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 4CO 24 VDC 1,500 VA Electromechanical Plug-In General Purpose Relay, 3 Amp At 250 VAC And 28 VDC, 6 Amp At 250/277 VAC And 28 VDC, 8 Amp At 30 VDC, RXM4AB3BD
$19.83 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 30 to 40 Amp, 690 VAC, Thermal IEC Overload Relay Trip Class 20, for LC1D80 and LC1D95, LR3D3555
$260.62 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 3 Pole, NEMA Size 00-1, 7 to 10 Amp, 690 VAC, Thermal NEMA Overload Relay, LRD14L
$162.19 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 37 to 50 Amp, 690 VAC, Thermal IEC Overload Relay Trip Class 10A, for LC1D40A and LC1D65A, LRD350
$295.92 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 37 to 50 Amp, 690 VAC, Thermal IEC Overload Relay Trip Class 20, for LC1D40A and LC1D65A, LRD350L
$270.16 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 1.25-5A Starter Control Unit For ASILUFC5, ASILUFC51, LUFC00, LUFDA01, LUFDA10, LUFDH11, LUFN, LUFV2, LUFW10, LULC031, LULC033, LULC07, LULC08, LULC09 And LULC15, LUCB05BL
$248.17 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 17 to 25 Amp, 690 VAC, Thermal IEC Overload Relay Trip Class 20, for LC1D40A and LC1D65A, LRD325L
$274.16 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 9 to 13 Amp, 690 VAC, Thermal IEC Overload Relay Trip Class 10A, for LC1D12 and LC1D38, LR3D16
$177.64 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 3 Pole, NEMA Size 0-1, 12 to 18 Amp, 690 VAC, Thermal NEMA Overload Relay, LR3D21L
$152.29 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 7 to 10 Amp, 690 VAC, Thermal IEC Overload Relay Trip Class 10A, for LC1D09 and LC1D38, LRD146
$175.33 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 17 To 25 Amp 690 VAC Trip Class 10A Thermal IEC Overload Relay For LC1D40A And LC1D65A, LRD325
$451.50 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 4 To 6 Amp 690 VAC Trip Class 10A Thermal IEC Overload Relay For LC1D09 And LC1D38, LR3D10
$148.22 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 63 to 80 Amp, 690 VAC, Thermal IEC Overload Relay Trip Class 20, for LC1D80 and LC1D95, LR3D3563
$312.08 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 90 To 150 Amp 690V Trip Class 10 And 10A Thermal IEC Overload Relay For LC1D115, LC1D150 And NSX Circuit Breakers, LR9D5369
$383.36 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Overload Relay, EF19-6.3
Overload Relay, EF19-6.3
SKU: EF19-6.3
ABB
SKU: EF19-6.3
Brand: ABB
$178.53 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of Overload Relay (30-40A)
Overload Relay (30-40A)
SKU: LRD3355
Square D
SKU: LRD3355
Brand: Square D
$175.58 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of Overload Relay 29.0-35.0, Tf42-35
Overload Relay 29.0-35.0, Tf42-35
SKU: TF42-35
ABB
SKU: TF42-35
Brand: ABB
$118.09 each
In Stock
Get 3 by Tue, Nov 24
In Stock
Get 3 by Tue, Nov 24
Compare
Product Image of Relay, 2271110-ESP
Relay, 2271110-ESP
SKU: 2271110-ESP
Embraco
SKU: 2271110-ESP
Brand: Embraco
$39.15 each
Out of Stock
Get it by Tue, Dec 8 - Tue, Dec 15
Out of Stock
Get it by Tue, Dec 8 - Tue, Dec 15
Compare
Product Image of Relay, 1SVR405618R2100
Relay, 1SVR405618R2100
SKU: 1SVR405618R2100
ABB
SKU: 1SVR405618R2100
Brand: ABB
$52.81 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Overload Relay, Manual Auto Reset, Size S0, Class 10, 7-10 Amp
$91.95 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of SIRIUS Safety Relay, 3 NO 1 NC (24V AC/DC)
SIRIUS Safety Relay, 3 NO 1 NC (24V AC/DC)
SKU: 3SK1111-2AB30
Siemens
SKU: 3SK1111-2AB30
Brand: Siemens
$544.09 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Overload Relay, Manual Auto Reset, Size S0, Class 10, 2.8-4 Amp
$104.98 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Stand-Alone Assembly Support for 3RU1 Overload Relays
Stand-Alone Assembly Support for 3RU1 Overload Relays
SKU: 3RU1936-3AA01
Siemens
SKU: 3RU1936-3AA01
Brand: Siemens
$25.08 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Overload Relay, 3RB3026-2SB0
Overload Relay, 3RB3026-2SB0
SKU: 3RB3026-2SB0
Siemens
SKU: 3RB3026-2SB0
Brand: Siemens
$202.03 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Overload Relay, Manual Auto Reset, Size S2, Class 10, 36-45 Amp
$117.36 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Overload Relay, Manual Auto Reset, Size S2, Class 10, 14-20 Amp
$123.89 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of NEMA Size 3 Melting Alloy Separate Mount Overload Relay (600VAC), 9065SEO12
$273.71 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of NEMA Size 2 Motor Logic Solid State Overload Relay, Replacement (15-45A, 600VAC), 9065ST220
$338.50 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Starter Control Terminal Block For LU6MB0 And TeSys U, LU9MR1
$19.09 each
In Stock
Get 2 by Wed, Nov 25 - Fri, Nov 27
In Stock
Get 2 by Wed, Nov 25 - Fri, Nov 27
Compare
Product Image of 32 Amp Non-Reversing Advanced Starter Power Base For TeSys U, LUB320
$1,059.61 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 10 to 14 Amp, 250 VDC, 690 Volt and 690 VAC, Thermal IEC Overload Relay, LR2K0321
$91.14 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 1 To 1.6 Amp 690 VAC Trip Class 10A Thermal IEC Overload Relay For LC1D09 And LC1D38, LR3D06
$154.04 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 2.5 to 4 Amp, 690 VAC, Thermal IEC Overload Relay Trip Class 10A, for LC1D09 and LC1D38, LR3D08
2.5 to 4 Amp, 690 VAC, Thermal IEC Overload Relay Trip Class 10A, for LC1D09 and LC1D38, LR3D08
SKU: LR3D08
Schneider Electric
SKU: LR3D08
$155.02 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 12 to 18 Amp, 690 VAC, Thermal IEC Overload Relay, LR3D21
12 to 18 Amp, 690 VAC, Thermal IEC Overload Relay, LR3D21
SKU: LR3D21
Schneider Electric
SKU: LR3D21
$147.52 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Resources
FAQs, Manuals & Videos
Articles
More About Overload Relays

Overload relays are protective devices that monitor motor current and interrupt power when a motor draws more amperage than it is rated for. Electricians and HVAC technicians install them in the same enclosure as a motor starter to protect compressors, blowers, and pumps from damage caused by a locked rotor, a failing bearing, or a prolonged overload condition. Most overload relays use either a bimetallic strip or an electronic current sensor to detect the fault, tripping a set of contacts that cuts power to the motor before windings overheat. Because a nuisance trip can shut down equipment unnecessarily, matching the relay's amperage range to the motor's actual full-load current is a key step during installation. Replacing a worn or mis-sized overload relay is one of the more common repairs on commercial refrigeration and rooftop HVAC equipment.

Subcategories

  • Bimetallic Overload Relays: Bimetallic overload relays use a heat-sensitive metal strip that bends as current passes through it, tripping the relay once the strip reaches a preset temperature tied to a specific overcurrent level. They are a common, cost-effective choice for standard motor starter applications. Manual or automatic reset options are typically available depending on how quickly a technician needs the circuit back in service.
  • Electronic Overload Relays: Electronic overload relays use current sensors and a solid-state circuit to detect an overload condition, often with adjustable trip points and additional protection features like phase-loss detection. They tend to offer more precise, repeatable trip settings than a bimetallic design. Many models display fault information that helps a technician diagnose why a motor tripped.
  • Overload Relay Heaters: Overload relay heaters are the replaceable elements inside a bimetallic relay that are sized to a specific motor's full-load amperage. Swapping the heater element lets a technician adjust an existing relay to protect a different motor without replacing the whole relay body. Heaters are selected from a manufacturer's amperage chart based on the motor's nameplate rating.
  • Buying Guide

    Sizing overload relays correctly starts with the motor's nameplate full-load current rather than the motor's horsepower rating, since two motors of the same horsepower can draw different amperage depending on voltage and efficiency. Most manufacturers publish an amperage range for each relay or heater element, and the goal is to select a range that brackets the motor's actual full-load current rather than just its maximum rated output. Reset style is worth considering next. A manual-reset relay requires someone to physically reset the device after a trip, which is useful when a technician wants to inspect the equipment before restarting it. An automatic-reset relay restores power on its own once the bimetallic strip cools, which suits unattended equipment where a nuisance trip should not leave a system down indefinitely. Ambient temperature at the installation location matters too, particularly for bimetallic relays, since some models are compensated for temperature swings in the enclosure and others are not. Overload relays installed in an uninsulated rooftop enclosure that sees wide seasonal swings benefit from a temperature-compensated design. Compatibility with the existing motor starter or contactor is the final check; overload relays are typically matched to a specific contactor frame size, so confirming fit before ordering avoids a part that will not mount correctly.

    Frequently Asked Questions

    How do I size an overload relay for a motor?

    Size the relay to the motor's full-load current listed on its nameplate, not its horsepower rating. Most manufacturers publish a chart matching amperage ranges to specific relay or heater part numbers.

    What is the difference between a manual and automatic reset overload relay?

    A manual-reset relay stays tripped until someone presses the reset button, while an automatic-reset relay restores power on its own once it cools down. Manual reset is preferred where a technician wants to check the equipment before restarting it.

    Why does an overload relay keep tripping even though the motor seems fine?

    A relay sized too small for the motor's actual running current will trip repeatedly even on a healthy motor. Checking the relay's amperage range against the motor's nameplate current is the first troubleshooting step.

    Can an overload relay heater be swapped without replacing the whole relay?

    Yes, on bimetallic-style relays the heater element is replaceable and can be resized to match a different motor without swapping the relay body.

    Do electronic overload relays need to be programmed?

    Most electronic overload relays require setting a trip current on a dial or keypad rather than full programming. Some models also let a technician set additional protections, like phase-loss detection, at the same time.