Apply to be a TradeMaster!
Filter menu expanded

Filters

561 items
Reset

SORT

Product Availability
–

Show In Stock Only (385)

Connection Size
–

1/4" (15)
1/2" (32)
5/8" (21)
3/4" (11)
7/8" (16)
1" (3)
1-1/8" (10)
1-3/8" (6)
1-5/8" (2)
3/8" (35)

Connection Type
–

Female Threaded (3)
Flare (2)
NPTF (1)
ODF (194)
ODM (3)
SAE (3)
SAE Flare (6)
Spade Terminals (2)
Sweat (10)
Threaded (17)

Voltage
–

120v (27)
240v (14)
12 VDC (5)
120/240V (4)
208 VAC (10)
208-240V (5)
208V (1)
220 VAC (4)
24 VAC (13)
24 VDC (7)

Review Score
–

(12)
(4)
(1)

Price Range
–

$5 to $10 (1)
$10 to $15 (4)
$15 to $20 (1)
$20 to $25 (6)
$25 to $30 (2)
$30 to $35 (3)
$35 to $40 (2)
$40 to $45 (1)
$45 to $50 (8)
$50 to $60 (19)

Refrigeration & Industrial Solenoid Valves

Help Face
Need a little help?
561 items
Grid
List
Compare
Product Image of 5/8" ODF 200RB7T5 2-Way Pilot-Operated Normally Closed Manual Stem Valve
$197.83 each
In Stock
Get 1 by Mon, Nov 23
In Stock
Get 1 by Mon, Nov 23
Compare
Product Image of M-12 Connector 18" Cable, 805620
M-12 Connector 18" Cable, 805620
SKU: 805620
Sporlan
SKU: 805620
Brand: Sporlan
$114.08 each
In Stock
Get 3 by Tue, Nov 24
In Stock
Get 3 by Tue, Nov 24
Compare
Product Image of KT-47 30" Element, 181521
KT-47 30" Element, 181521
SKU: 181521
Sporlan
SKU: 181521
Brand: Sporlan
$93.93 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of KS-CDS-9 Motor & Adaptor Assembly Kit
$1,012.28 each
In Stock
Get 3 by Tue, Nov 24
In Stock
Get 3 by Tue, Nov 24
Compare
Product Image of 18E23C2-R1021E 9 ODF Normally Closed Secondary Coolant Valve w/o Coil, 0-150psi (5 Cv)
$508.54 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 1/2" x 5/8" 2-Way Normally Closed Valve (3.6 Cv)
$124.43 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 10 Watt Class F Open Spade Connection Coil (24V)
$52.47 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Compare
Product Image of 24 VAC Coil, 10W
24 VAC Coil, 10W
SKU: C111B2
Parker Hannifin
SKU: C111B2
$60.91 each
In Stock
Get 3 by Tue, Nov 24
In Stock
Get 3 by Tue, Nov 24
Compare
Product Image of ORB/RB9 Series Refrigeration Valve Repair Kit
$101.73 each
In Stock
Get 20 by Tue, Nov 24
In Stock
Get 20 by Tue, Nov 24
Compare
Product Image of KS-XRM Disc/ Piston/ Diaphragm Kit for Rapid Cycle Valves
$316.31 each
In Stock
Get 1 by Mon, Nov 23
In Stock
Get 1 by Mon, Nov 23
Compare
Product Image of 3/8" ODF R26E63M Normally Closed Refrigeration Solenoid Valve
$173.81 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of 1/2" ODF R36E104M Normally Closed Refrigeration Solenoid Valve
$340.87 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Compare
Product Image of 5/8" x 7/8" ODF R-22 10 Ton TXV, 124219
$596.17 each
In Stock
Get 3 by Tue, Nov 24
In Stock
Get 3 by Tue, Nov 24
Compare
Product Image of 3/8" ODF 200RB5T3 2-Way Pilot-Operated Normally Closed Standard Valve
$112.16 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of 12 Watt ASC2-Series Open Frame Conduit Connection Coil (24V)
$113.93 each
In Stock
Get 3 by Tue, Nov 24
In Stock
Get 3 by Tue, Nov 24
Compare
Product Image of Solenoid Service Magnet
Solenoid Service Magnet
SKU: 310250
Sporlan
SKU: 310250
Brand: Sporlan
$108.25 each
In Stock
Get 3 by Tue, Nov 24
In Stock
Get 3 by Tue, Nov 24
Compare
Product Image of KS-B10/E10-HP Internal Parts Kit for Normally Closed Valves
$197.11 each
In Stock
Get 1 by Mon, Nov 23
In Stock
Get 1 by Mon, Nov 23
Compare
Product Image of 3/8" Npt 150 Psi W6p1 Air/water/steam Valve, 3901-00
$188.30 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Compare
Product Image of 1/4" ODF R16E32 Normally Closed Refrigeration Solenoid Valve
$121.35 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of 15 Watt ASC2-Series Open Frame Conduit Connection Coil (208-240V)
$99.21 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 5/8" ODF Normally Closed Secondary Coolant Valve (4 Cv)
$367.74 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Ol-60ar Oil Level Control, 960093
Ol-60ar Oil Level Control, 960093
SKU: 960093
Sporlan
SKU: 960093
Brand: Sporlan
$579.13 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Of-303-bp Oil Filter, 960014
Of-303-bp Oil Filter, 960014
SKU: 960014
Sporlan
SKU: 960014
Brand: Sporlan
$281.80 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 1-1/8" Aux. Side Connector
1-1/8" Aux. Side Connector
SKU: 206841
Sporlan
SKU: 206841
Brand: Sporlan
$235.52 each
In Stock
Get 2 by Mon, Nov 23
In Stock
Get 2 by Mon, Nov 23
Compare
Product Image of MKC-2 JAK 12VDC Coil w/ Junction Box
$196.22 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Compare
Product Image of Ks-e35-hp Solenoid Valve Rebuild Kit, 958741
$683.81 each
In Stock
Get 5 by Tue, Nov 24
In Stock
Get 5 by Tue, Nov 24
Compare
Product Image of 7/8" ODF- 1-1/8" ODM MB19S2 2-Way Normally Closed Solenoid Valve
$683.86 each
In Stock
Get 3 by Tue, Nov 24
In Stock
Get 3 by Tue, Nov 24
Compare
Product Image of Normally Closed Solenoid Valve Body E3s140, 1/2" Odf, Without Coil, 4198-00
$159.84 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of Me10s150-hp, Me, No Coil, Valve, 4342-00
$251.55 each
In Stock
Get 1 by Mon, Nov 23
In Stock
Get 1 by Mon, Nov 23
Compare
Product Image of 120V Coil Asc2, 015384
120V Coil Asc2, 015384
SKU: 015384
Copeland
SKU: 015384
Brand: Copeland
$114.07 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Compare
Product Image of 3/8" ODF 200RB4T3 2-Way Pilot-Operated Manual Stem Valve
$119.36 each
In Stock
Get 3 by Tue, Nov 24
In Stock
Get 3 by Tue, Nov 24
Compare
Product Image of 1-1/8" ODF 540RA12T9-Series 2-Way Normally Open Standard Diaphragm Valve
$374.40 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of 5/8" ODF 200RB 2-Way Pilot-Operated Manual Stem Valve
$111.46 each
In Stock
Get 2 by Mon, Nov 23
In Stock
Get 2 by Mon, Nov 23
Compare
Product Image of 1-1/8" x 1 5/8" R-404A 30 Ton TXV, 124960
$1,076.33 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of MKC-2 120V/208-240V Coil w/ Conduit Box
$276.75 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 5/8" Sweat Nc Manual Steam, W/O Coil9/16, 1840079
$211.88 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 1/2" ODF EXT XRN-3 W/MH 2-Way Normally Closed Solenoid Valve
$888.26 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Compare
Product Image of 1/4" Buna-N Direct-Acting Unidirectional Normally Closed Valve (0.7 Cv)
$74.19 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Compare
Product Image of Asc2L 24V 60H Coil, 063542
Asc2L 24V 60H Coil, 063542
SKU: 063542
Copeland
SKU: 063542
Brand: Copeland
$121.57 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of 3/4" NC 0/100# DirectLift NBR
3/4" NC 0/100# DirectLift NBR
SKU: 72218BN5VN00
Parker Hannifin
SKU: 72218BN5VN00
$242.84 each
In Stock
Get 3 by Tue, Nov 24
In Stock
Get 3 by Tue, Nov 24
Compare
Product Image of OMKC-2 DUAL 120-208-240V/50-60V Coil w/ Junction Box
$151.52 each
In Stock
Get 4 by Tue, Nov 24
In Stock
Get 4 by Tue, Nov 24
Compare
Product Image of 3/8" Sweat Ball Valve w/ Access, V34500
$66.91 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of Bq Case - Stocked Solder Thermostatic Expansion Valve, 168392
$1,717.00 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Element Kit KT-47-L2, 181550
Element Kit KT-47-L2, 181550
SKU: 181550
Sporlan
SKU: 181550
Brand: Sporlan
$160.24 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of KIT-CABLE-M12-40'-S-4 Wire, 805344
KIT-CABLE-M12-40'-S-4 Wire, 805344
SKU: 805344
Sporlan
SKU: 805344
Brand: Sporlan
$314.52 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Sensor, Blue
Sensor, Blue
SKU: 230076
Sporlan
SKU: 230076
Brand: Sporlan
$53.32 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Compare
Product Image of PKC-2-24DC Solenoid Coil for Normally Closed Refrigeration Solenoid Valves (24 VDC)
$162.83 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Compare
Product Image of OMKC-2 JAK 24 VDC Coil w/ Junction Box
$174.54 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Resources
FAQs, Manuals & Videos
Articles
More About Refrigeration & Industrial Solenoid Valves

Refrigeration and industrial solenoid valves are electrically operated valves that open or close fluid or refrigerant flow using a coil-driven plunger, giving a control system fast, repeatable on and off switching without a manually operated valve. When the coil is energized, it lifts or lowers the plunger to open the flow path, and de-energizing the coil returns the plunger to its normal position, which is either closed or open depending on the valve's design. These valves show up throughout refrigeration racks, chillers, and industrial process lines wherever a thermostat, pressure switch, or controller needs to start or stop flow automatically. A solenoid valve is typically paired with a matching coil sold separately, since the same valve body can often accept different coil voltages depending on the control circuit it's wired into. Technicians troubleshoot no-flow or stuck-open complaints by checking coil resistance and confirming voltage at the coil before assuming the valve body itself has failed.

Subcategories

  • Solenoid Valve Bodies: Valve bodies are the mechanical portion of the assembly, containing the plunger, seat, and ports that control flow once a coil is installed and energized. They're specified by port size, pressure rating, and whether they're normally open or normally closed in their de-energized state. A valve body is typically sold without a coil, so the correct coil voltage still needs to be selected separately to complete the assembly. Matching the body's material and seal compatibility to the refrigerant or fluid in the system is critical to avoid premature seal failure.
  • Replacement Coils: Coils are the electromagnetic component that lifts the plunger inside a compatible valve body when energized. They're specified by voltage, frequency, and physical mounting style to match the valve body they're paired with. A coil is one of the more common failure points in a solenoid valve assembly, often showing symptoms like a valve that hums but doesn't open or one that draws no current at all. Replacing just the coil is usually far less expensive and disruptive than replacing the entire valve body when only the coil has failed.
  • Normally Closed Valves: Normally closed valves stay shut when the coil is de-energized and open only when power is applied, making them the standard choice for most refrigeration and process applications where flow should stop by default if power is lost. This fail-safe behavior is important on refrigerant lines and other systems where uncontrolled flow during a power interruption could cause damage. Selecting a normally closed valve for a new application is the safer default unless the process specifically requires the opposite behavior.
  • Normally Open Valves: Normally open valves stay open when de-energized and close only when the coil is powered, which suits applications where flow needs to continue by default during a power loss. These are less common than normally closed valves but are specified deliberately in processes where stopping flow, rather than allowing it, would create a hazard or damage equipment. Confirming which failure mode a given application actually requires before ordering avoids installing a valve that behaves opposite to what the system needs during an outage.
  • Buying Guide

    Start with the fluid or refrigerant type moving through the valve, since seal and body materials need to be compatible with it to avoid premature failure. A valve rated for one refrigerant family isn't automatically suitable for another.

    Confirm the required failure mode before selecting normally open or normally closed. Most refrigeration and process applications default to normally closed so flow stops automatically if power is interrupted, but some processes specifically need flow to continue during an outage.

    Size the valve's port and orifice to the system's flow requirements and available pressure differential, since an undersized valve restricts flow more than intended and an oversized one can be harder to control precisely.

    When selecting refrigeration and industrial solenoid valves as a replacement, match the coil voltage and mounting style to the control circuit already in place rather than assuming a universal fit, since coils vary by voltage, frequency, and physical connection type.

    Finally, stock replacement coils separately from valve bodies for common models already in the field, since a coil failure is one of the more frequent service calls and swapping just the coil is faster and less costly than replacing the entire assembly.

    Frequently Asked Questions

    What's the difference between a normally open and normally closed solenoid valve?

    A normally closed valve stays shut until the coil is energized, while a normally open valve stays open until the coil is energized. The choice depends on how the system should behave if power is lost.

    Can a solenoid coil be replaced without replacing the valve body?

    Yes, in most cases the coil and valve body are separate components, and a failed coil can be swapped out on its own as long as the replacement coil matches the required voltage and mounting style.

    Why would a solenoid valve hum but not open?

    A humming valve that doesn't open often points to a weak or partially failed coil, low supply voltage, or debris obstructing the plunger. Checking coil resistance and voltage at the coil helps narrow down the cause.

    How is a solenoid valve sized for an application?

    Sizing depends on the required flow rate, the available pressure differential across the valve, and the port size needed to avoid excessive restriction. Undersizing the valve limits flow more than the system needs.

    Does the refrigerant type affect which solenoid valve to use?

    Yes, seal and body materials need to be compatible with the specific refrigerant or fluid passing through the valve. Using a valve rated for a different fluid family can cause the seals to degrade prematurely.