White Rodgers Contactors are electrical contactors for central air conditioning and heating equipment, and the listing covers 2 pole and 3 pole models with 24 VAC, 120 VAC, and 208/240 VAC coils. Contact ratings in the records include 30 amp and 40 amp. The 2 pole Type 122 models list double break contacts, a low VA coil for cooler operation and increased life, and a universal style mounting bracket that fits existing mounting holes. Coil voltage and contact rating are the first specs to match, because the contactor has to suit both the control circuit and the load it switches. The 3 pole contactor in the listing has a 24 VAC coil with 30 amp contacts, 7.2 ohms DC resistance, and 187 mA, so the coil details differ from model to model.
Subcategories
Buying Guide
Start with the coil voltage, since it must match the control circuit on the equipment. The records list 24 VAC, 120 VAC, and 208/240 VAC coils, and each coil has its own DC resistance and current draw, such as 250 mA for a 24 VAC Type 122 coil, 50 mA for 120 VAC, and 25 mA for 208/240 VAC.
Next, check the contact rating. The 2 pole Type 122 records show 30 amp contacts, and one 24 VAC version shows 40 amp contacts. The 3 pole model is listed with 30 amp contacts. Pick a rating that covers the load being switched.
Then decide the number of poles. A 2 pole and a 3 pole contactor are different devices, so count the legs the equipment needs to switch before choosing.
When comparing White Rodgers Contactors, look at construction features too. Double break contacts, a low VA coil, and a universal style mounting bracket are listed on the Type 122 models, while the 3 pole model lists any position mounting and an interchangeable mounting plate. Check frequency as well, since the records list 50 and 60 hertz for some models and 60 hertz only for the 208/240 VAC model.
Confirm the match against the equipment nameplate or the original part number, and ask the SupplyHouse team if the fit is unclear.
Frequently Asked Questions
What coil voltages are included in White Rodgers Contactors?
White Rodgers Contactors in the listing include 24 VAC, 120 VAC, and 208/240 VAC coil versions. The 2 pole Type 122 line covers all three voltages. Match the coil voltage to the control circuit on the equipment.
What's the difference between the 30 amp and 40 amp Type 122 contactors?
The White Rodgers 2 pole Type 122 contactors with a 24 VAC coil are listed with either 30 amp or 40 amp contacts. Both list 11 ohms DC resistance and 250 mA, so the coil details match and the contact rating is the difference. Pick the rating that covers the load.
Do White Rodgers contactors have double break contacts?
The White Rodgers 2 pole Type 122 contactors and the 3 pole contactor in the listing are described with double break contacts. Product details describe positive make and break. Confirm the details on the product page for the specific model.
Can I mount a White Rodgers contactor in any position?
The White Rodgers 3 pole contactor in the listing is described with any position mounting and an interchangeable mounting plate. The 2 pole Type 122 models list a universal style mounting bracket that fits existing mounting holes. Check the product page for the mounting details on the specific model.
What's the coil current on White Rodgers Type 122 contactors?
White Rodgers Type 122 coil current depends on the coil voltage, at 250 mA for 24 VAC, 50 mA for 120 VAC, and 25 mA for 208/240 VAC. All of the Type 122 records list 6 VA nominal and 32 VA inrush. Confirm the numbers on the specific model before ordering.