Apply to be a TradeMaster!
Filter menu expanded

Filters

460,971 items
Reset

SORT

Wilo Top S Pump Parts

Help Face
Need a little help?
460971 items
Grid
List
Compare
Product Image of YSC090F3ELA000 Parts - Trane Packaged Gas/electricnot-to-sell-product
YSC090F3ELA000 Parts - Trane Packaged Gas/electric
SKU: YSC090F3ELA000
Trane
SKU: YSC090F3ELA000
Brand: Trane
Backorder
Get it by Tue, Feb 23 - Tue, May 18
Backorder
Get it by Tue, Feb 23 - Tue, May 18
Compare
Product Image of YSC090HWEMA001S Parts - Gas Electric Packaged Commercial Unitnot-to-sell-product
YSC090HWEMA001S Parts - Gas Electric Packaged Commercial Unit
SKU: YSC090HWEMA001S
Trane
SKU: YSC090HWEMA001S
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of 22mm Blue Push-Button Switch, ZB4BW36
$24.69 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of FE81 3-Phase TEFC General Purpose Motor, 286T Frame (230/460V, 30 HP, 1775 RPM), YC30P2B
$5,877.64 each
In Stock
Get 5 by Tue, Dec 1 - Fri, Dec 4
In Stock
Get 5 by Tue, Dec 1 - Fri, Dec 4
Compare
Product Image of YCC018F1L0BJ Parts - Trane Packaged Unit/RTUnot-to-sell-product
YCC018F1L0BJ Parts - Trane Packaged Unit/RTU
SKU: YCC018F1L0BJ
Trane
SKU: YCC018F1L0BJ
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of YCC030F1M0BH Parts - Trane Packaged Unit/RTUnot-to-sell-product
YCC030F1M0BH Parts - Trane Packaged Unit/RTU
SKU: YCC030F1M0BH
Trane
SKU: YCC030F1M0BH
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Limit Switch Lever, ZCKY15
$7.64 each
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of Limit Switch Lever, ZCKY51
$7.14 each
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of Limit Switch Lever, ZCKY81
$10.62 each
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of Connector NC NO SA CAB 25M 5 Conductors, ZCMC21L25
$145.88 each
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of Body Limit Switch NC+NO Snap,  Amp 4P, ZCMD21AM4
$60.36 each
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of Limit Switch Metal NO and NC, ZCMD21L1R12SCU
$79.25 each
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of Harmony XVU Illuminated LED Modular Tower Light, Steady, IP65 - Yellow (24 VAC/DC)
$42.39 each
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of Tower Light Module, Harmony XV4, Grey, XVZ06
$22.99 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Sensor Pushbutton, For Ultrasonic Sensor, XXZPB100
$85.46 each
In Stock
Get 1 by Fri, Nov 27 - Mon, Nov 30
In Stock
Get 1 by Fri, Nov 27 - Mon, Nov 30
Compare
Product Image of Safety Limit Switch, NO/NC, 30m Cable, Series 33, XY2CH33010H7
$315.96 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Push-Button Switch, 22 mm Mounting Hole Dia, Momentary, Round, Yellow Pushbutton, Nonilluminated, Momentary, ZB5AC5
$44.51 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of YCJD36S44S3EA Parts - York Central Air Conditionernot-to-sell-product
YCJD36S44S3EA Parts - York Central Air Conditioner
SKU: YCJD36S44S3EA
York
SKU: YCJD36S44S3EA
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of YCJD42S41S1A Parts - York Central Air Conditionernot-to-sell-product
YCJD42S41S1A Parts - York Central Air Conditioner
SKU: YCJD42S41S1A
York
SKU: YCJD42S41S1A
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of YCJD42S41S1H Parts - York Central Air Conditionernot-to-sell-product
YCJD42S41S1H Parts - York Central Air Conditioner
SKU: YCJD42S41S1H
York
SKU: YCJD42S41S1H
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of YCJD42S41S1HA Parts - York Central Air Conditionernot-to-sell-product
YCJD42S41S1HA Parts - York Central Air Conditioner
SKU: YCJD42S41S1HA
York
SKU: YCJD42S41S1HA
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of YCJD42S41S2HEA Parts - York Central Air Conditionernot-to-sell-product
YCJD42S41S2HEA Parts - York Central Air Conditioner
SKU: YCJD42S41S2HEA
York
SKU: YCJD42S41S2HEA
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of 8" x 6" Modulating Commercial Zone Damper, ZD-0806
$383.60 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 20" x 6" Modulating Commercial Zone Damper, ZD-2006
$423.75 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 24" x 10" Modulating Commercial Zone Damper - Bottom Mount, ZD-2410-BM
$444.77 each
In Stock
Get 1 by Mon, Nov 30 - Wed, Dec 2
In Stock
Get 1 by Mon, Nov 30 - Wed, Dec 2
Compare
Product Image of XYAS14301A Parts - York Central Air Conditionernot-to-sell-product
XYAS14301A Parts - York Central Air Conditioner
SKU: XYAS14301A
York
SKU: XYAS14301A
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of XYHS13241A Parts - York Heat Pumpnot-to-sell-product
XYHS13241A Parts - York Heat Pump
SKU: XYHS13241A
York
SKU: XYHS13241A
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of XYPH1342AAA Parts - York Heat Pumpnot-to-sell-product
XYPH1342AAA Parts - York Heat Pump
SKU: XYPH1342AAA
York
SKU: XYPH1342AAA
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Sensor Cordset, M8 4-Pin Female Straight, 5m Cable, 4 Amp, 60 VAC, IP67, XZCP0941L5
$26.92 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Harmony XB5R Wireless Push Button, Marked O, Spring Return, w/o Battery, Plastic, Red
$131.42 each
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of YCJD48S21S2HA Parts - York Central Air Conditionernot-to-sell-product
YCJD48S21S2HA Parts - York Central Air Conditioner
SKU: YCJD48S21S2HA
York
SKU: YCJD48S21S2HA
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of YCJD48S41S1EA Parts - York Central Air Conditionernot-to-sell-product
YCJD48S41S1EA Parts - York Central Air Conditioner
SKU: YCJD48S41S1EA
York
SKU: YCJD48S41S1EA
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
YCJD60S41S1B Parts - York Central Air Conditioner
SKU: YCJD60S41S1B
York
SKU: YCJD60S41S1B
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Flara 24" Grab Bar, YG0324NL (Polished Nickel)
Flara 24" Grab Bar, YG0324NL (Polished Nickel)
SKU: YG0324NL
Moen
SKU: YG0324NL
Brand: Moen
$271.87 each
Out of Stock
Get it by Fri, Dec 18 - Mon, Dec 28
Out of Stock
Get it by Fri, Dec 18 - Mon, Dec 28
Compare
Product Image of 26" x 8" Modulating Commercial Zone Damper, ZD-2608
$492.16 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 26" x 10" Modulating Commercial Zone Damper, ZD-2610
$521.87 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 28" x 16" Modulating Commercial Zone Damper, ZD-2816
$616.36 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Y13AC04C6IDEBDA Parts - York Central Air Conditionernot-to-sell-product
Y13AC04C6IDEBDA Parts - York Central Air Conditioner
SKU: Y13AC04C6IDEBDA
York
SKU: Y13AC04C6IDEBDA
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Y13AN24Q2KAABB Parts - York Central Air Conditionernot-to-sell-product
Y13AN24Q2KAABB Parts - York Central Air Conditioner
SKU: Y13AN24Q2KAABB
York
SKU: Y13AN24Q2KAABB
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Y13AN25M1KANBCA Parts - York Central Air Conditionernot-to-sell-product
Y13AN25M1KANBCA Parts - York Central Air Conditioner
SKU: Y13AN25M1KANBCA
York
SKU: Y13AN25M1KANBCA
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Multiple Amp Levels, Electrical Switch Contact Block Screw Terminal, ZBE1016
$40.15 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Contact Block, Harmony XB4, Silver Alloy, 1NC, ZBE202
$10.67 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Harmony ZB Wireless Push Button w/ Simple & Double Action Buttons, ZBRT Transmitter, w/o Battery
$435.06 each
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of Transmitter for Wireless & Batteryless Push Button, Double Action - Black
Transmitter for Wireless & Batteryless Push Button, Double Action - Black
SKU: ZBRT2
$116.74 each
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of 24 V White Lens LED Indicating Light, ZBVB1
$57.38 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Compare
Product Image of LED Indicating Light (Green), ZBVB37
$30.91 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 14 in. x 28 in. TrueZONE Rectangular Parallel Blade Damper
$377.80 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Y13AN42A3IANDA Parts - York Central Air Conditionernot-to-sell-product
Y13AN42A3IANDA Parts - York Central Air Conditioner
SKU: Y13AN42A3IANDA
York
SKU: Y13AN42A3IANDA
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Resources
FAQs, Manuals & Videos
Articles
More About Wilo Top S Pump Parts

Wilo Top S pump parts keep the Wilo Top S line of hydronic circulator pumps running in residential and light commercial heating and cooling systems. Wilo Top S circulators move hot or chilled water through hydronic piping in boiler, radiant, and fan coil applications, and replacement parts extend the service life of pumps already installed in the field. Common parts include motor cartridges, seal kits, gaskets, and control modules that wear or fail well before the pump housing itself needs replacement. Technicians servicing a Wilo Top S pump typically diagnose whether the issue is electrical, mechanical, or related to a worn wet end before ordering parts. Stocking the right cartridge and seal combination for a given pump size shortens repair time on a callback. Sourcing genuine Wilo replacement parts helps maintain the pump's original flow and efficiency performance rather than settling for a full pump swap.

Subcategories

  • Motor Cartridges: Motor cartridges contain the wet-rotor motor assembly that drives the pump impeller. Technicians replace a cartridge when the motor windings fail or bearings wear out, since the cartridge can typically be swapped without removing the pump body from the piping. Matching cartridge voltage and pump size to the installed housing is essential for proper fit. Replacing the cartridge alone is usually faster and less disruptive than replacing the entire pump.
  • Seal and Gasket Kits: Seal and gasket kits address leaks at the pump housing and cartridge interface, a common failure point in circulators that run continuously through a heating season. Technicians inspect for mineral buildup or a hardened gasket before assuming the pump body itself is damaged. Replacing seals proactively during scheduled maintenance can prevent a leak from becoming a no-heat emergency call. Kits are sized to match specific Wilo Top S pump models.
  • Control Modules: Control modules on variable-speed Wilo Top S pumps manage speed settings and communicate operating status. A failed module often causes the pump to run at a fixed speed or stop responding to system demand. Technicians troubleshoot wiring and power supply before replacing a module outright. Choosing the correct module version for the pump's control type avoids compatibility issues.
  • Flanges and Mounting Hardware: Flanges and mounting hardware connect the Wilo Top S pump body to the system piping and support proper alignment. Worn or corroded flange gaskets are a frequent source of slow leaks around the pump connection points. Technicians replace flange hardware during a full pump service to prevent recurring leaks. Correct flange sizing keeps the pump properly aligned with existing piping runs.
  • Buying Guide

    Ordering the correct Wilo Top S pump parts starts with confirming the exact pump model and voltage printed on the unit's nameplate, since cartridges and control modules are not interchangeable across the full Top S lineup. Technicians should determine whether the pump uses a fixed-speed or variable-speed motor cartridge before ordering a replacement, since installing the wrong type can leave the system without proper speed control. When a pump is leaking, checking whether the failure is at the seal, the gasket, or a cracked housing helps determine whether a seal kit will resolve the issue or a full cartridge or pump replacement is needed. For control modules, confirming the communication protocol the building automation system expects prevents a mismatch between the new module and existing controls. Contractors stocking Wilo Top S pump parts for commercial service routes often keep cartridges and seal kits on hand for the pump sizes most common in their service area, since hydronic systems can fail without much warning during cold weather. Reviewing the pump's original installation documentation, when available, helps confirm the exact part numbers needed and reduces the chance of ordering an incompatible component. Replacing worn parts on a Wilo Top S pump promptly, rather than waiting for a full failure, typically costs less in labor than an emergency pump swap during peak heating season.

    Frequently Asked Questions

    Can a Wilo Top S motor cartridge be replaced without draining the whole system?

    Most Wilo Top S pumps allow the cartridge to be removed while isolating the pump with flange-mounted isolation valves, limiting water loss to the pump body itself. Systems without isolation valves will require draining before cartridge replacement. Checking for isolation valves ahead of the service call helps technicians plan the repair more efficiently.

    What typically causes a Wilo Top S pump to run noisy?

    Noise often points to air trapped in the system, a worn bearing inside the motor cartridge, or debris caught in the impeller. Bleeding air from the system is usually the first troubleshooting step before replacing any parts. Persistent grinding or humming after bleeding usually indicates a cartridge replacement is needed.

    How do I identify the correct replacement seal kit for a Wilo Top S pump?

    The pump's model number and size, found on the nameplate, determine the correct seal kit, since kits vary by pump body size. Technicians should record this information before removing the pump for service. Ordering by nameplate model number avoids fit issues with the wrong kit.

    Why would a variable-speed Wilo Top S pump stop responding to a building automation system?

    A failed or disconnected control module is a common cause, along with wiring faults at the communication terminals. Technicians should verify power and signal wiring before replacing the module. Confirming the module's communication protocol matches the automation system prevents recurring issues after replacement.

    Is it possible to upgrade a fixed-speed Wilo Top S pump to variable-speed using replacement parts?

    Fixed-speed and variable-speed Wilo Top S pumps use different motor cartridges and control architectures, so an upgrade generally requires a cartridge designed for variable-speed operation along with a compatible control module. Confirming the pump housing supports the variable-speed cartridge is an important step before ordering parts. Contractors should check manufacturer documentation to confirm compatibility before attempting the upgrade.