Apply to be a TradeMaster!
Filter menu expanded

Filters

463,427 items
Reset

SORT

Wilo Z-15 Pump Parts

Help Face
Need a little help?
463427 items
Grid
List
Compare
Product Image of HB048HELNDCC1XX1 Parts - Heil Quaker (ICP) Geothermal Hp, Packaged Unit, Low Tiernot-to-sell-product
Backorder
Get it by Thu, Feb 25 - Thu, May 20
Backorder
Get it by Thu, Feb 25 - Thu, May 20
Compare
Product Image of HB048HSRCXCC1XX1 Parts - Heil Quaker (ICP) Geothermal Hp, Packaged Unit, Low Tier, 4.0 Ton, 208/230-1-60not-to-sell-product
Backorder
Get it by Thu, Feb 25 - Thu, May 20
Backorder
Get it by Thu, Feb 25 - Thu, May 20
Compare
Product Image of HB048HSRNXCC1XX1 Parts - Heil Quaker (ICP) Geothermal Hp, Packaged Unit, Low Tier, 4.0 Ton, 208/230-1-60not-to-sell-product
Backorder
Get it by Thu, Feb 25 - Thu, May 20
Backorder
Get it by Thu, Feb 25 - Thu, May 20
Compare
Product Image of HB048VTLCDCC1XX1 Parts - Heil Quaker (ICP) Geothermal Hp, Packaged Unit, Low Tier, 4.0 Ton, 208/230-1-60not-to-sell-product
HB048VTLCDCC1XX1 Parts - Heil Quaker (ICP) Geothermal Hp, Packaged Unit, Low Tier, 4.0 Ton, 208/230-1-60
SKU: HB048VTLCDCC1XX1
Heil Quaker (ICP)
SKU: HB048VTLCDCC1XX1
Backorder
Get it by Thu, Feb 25 - Thu, May 20
Backorder
Get it by Thu, Feb 25 - Thu, May 20
Compare
Product Image of HB048VTLNDCC1XX1 Parts - Heil Quaker (ICP) Geothermal Hp, Packaged Unit, Low Tier, 4.0 Ton, 208/230-1-60not-to-sell-product
HB048VTLNDCC1XX1 Parts - Heil Quaker (ICP) Geothermal Hp, Packaged Unit, Low Tier, 4.0 Ton, 208/230-1-60
SKU: HB048VTLNDCC1XX1
Heil Quaker (ICP)
SKU: HB048VTLNDCC1XX1
Backorder
Get it by Thu, Feb 25 - Thu, May 20
Backorder
Get it by Thu, Feb 25 - Thu, May 20
Compare
Product Image of 1-1/4" Sweat Run x 1" Hydro-Core Right Flange Manifold w/ 3/4" Sweat Union Connection
$330.20 each
In Stock
Get 1 by Tue, Dec 1 - Wed, Dec 2
In Stock
Get 1 by Tue, Dec 1 - Wed, Dec 2
Compare
Product Image of 1" Push-Fit x FNPT Union Ball Valve (Lead Free)
$86.23 each
In Stock
Get 221 by Tue, Dec 1 - Wed, Dec 2
In Stock
Get 221 by Tue, Dec 1 - Wed, Dec 2
Compare
Product Image of HOV13A-Oil Hydramotor Actuator with Auxiliary Switch (120V)
$2,939.41 each
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Compare
Product Image of Label, Elect, Warning, Shock, H0269100
Label, Elect, Warning, Shock, H0269100
SKU: H0269100
Laars
SKU: H0269100
Brand: Laars
$5.56 each
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Compare
Product Image of H036AKA1 Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Wed, Dec 30 - Tue, Feb 2
Backorder
Get it by Wed, Dec 30 - Tue, Feb 2
Compare
Product Image of 125 VAC, 20 Amp, L5-20R NEMA, Self Grounding Receptacle, HBL2310
$48.64 each
In Stock
Get 66 by Tue, Dec 1 - Wed, Dec 2
In Stock
Get 66 by Tue, Dec 1 - Wed, Dec 2
Compare
Product Image of 1" MIP x G1 Brass Union w/ Integral Check Valve (Lead Free)
$20.92 each
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Compare
Product Image of 20A Industrial Locking Connector, L21-20R, 120 & 208V, Shrouded, Black & White, HBL2513SW
$184.52 each
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Compare
Product Image of 120/208 VAC, 20 Amp, 21-20P NEMA, Self Grounding Inlet, HBL2515SW
$168.68 each
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Compare
Product Image of HBBA-F030S Parts - York Central Air Conditionernot-to-sell-product
HBBA-F030S Parts - York Central Air Conditioner
SKU: HBBA-F030S
York
SKU: HBBA-F030S
Brand: York
Backorder
Get it by Wed, Dec 30 - Tue, Feb 2
Backorder
Get it by Wed, Dec 30 - Tue, Feb 2
Compare
Product Image of Low Voltage Relay Control Section, 25 A (240V)
$329.98 each
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Compare
Product Image of Low Voltage Relay Control Section, 25 A (208V)
$329.99 each
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Compare
Product Image of 1/2" Press Solar Thermostatic Mixing Valve w/ Check Valve (Lead Free)
$152.22 each
In Stock
Get 1 by Tue, Dec 1 - Wed, Dec 2
In Stock
Get 1 by Tue, Dec 1 - Wed, Dec 2
Compare
Product Image of 2P 3 Wire 480 VAC, 30 Amp, L8-30R NEMA, Self Grounding Receptacle, Black, HBL2640
$71.73 each
In Stock
Get 5 by Tue, Dec 1 - Wed, Dec 2
In Stock
Get 5 by Tue, Dec 1 - Wed, Dec 2
Compare
Product Image of 3P 30A Industrial Locking Plug, L15-30P, 250V Male, Black & White, HBL2721SW
$239.41 each
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Compare
Product Image of 250 VAC, 30 Amp, Non-NEMA, Self Grounding Receptacle, Black, HBL3430G
$97.64 each
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Compare
Product Image of HBC090M1BA Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Wed, Dec 30 - Tue, Feb 2
Backorder
Get it by Wed, Dec 30 - Tue, Feb 2
Compare
Product Image of HBC180S1AA Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Wed, Dec 30 - Tue, Feb 2
Backorder
Get it by Wed, Dec 30 - Tue, Feb 2
Compare
Product Image of HBHB-T120AC Parts - Central Air Conditionernot-to-sell-product
HBHB-T120AC Parts - Central Air Conditioner
SKU: HBHB-T120AC
Coleman
SKU: HBHB-T120AC
Brand: Coleman
Backorder
Get it by Wed, Dec 30 - Tue, Feb 2
Backorder
Get it by Wed, Dec 30 - Tue, Feb 2
Compare
Product Image of HBHB-W120AC Parts - Coleman Air Conditionernot-to-sell-product
HBHB-W120AC Parts - Coleman Air Conditioner
SKU: HBHB-W120AC
Coleman
SKU: HBHB-W120AC
Brand: Coleman
Backorder
Get it by Wed, Dec 30 - Tue, Feb 2
Backorder
Get it by Wed, Dec 30 - Tue, Feb 2
Compare
Product Image of 6-15P Industrial 250VAC Yellow Straight Blade Plug, HBL14W49
$31.46 each
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Compare
Product Image of 6 Outlets, 125 Volts, 15 Amps, 6' Cord, Power Outlet Strip, Ivory, HBL20C215IV
$206.69 each
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Compare
Product Image of Straight Blade Duplex Receptacle, NEMA 5-15R, 15A, Self-Grounding, Gray, HBL5252GY
$33.23 each
In Stock
Get 5 by Tue, Dec 1 - Wed, Dec 2
In Stock
Get 5 by Tue, Dec 1 - Wed, Dec 2
Compare
Product Image of 2 Pole, 3 Wire, 250 VAC, 20 Amp, NEMA L6-20R, Self-Grounding Receptacle, Gray, HBL2320AR
$43.83 each
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Compare
Product Image of 2P 3 Wire 250 VAC, 20 Amp, L6-20R NEMA, Self Grounding Receptacle, Gray, HBL2320SR
$54.56 each
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Compare
Product Image of 2P 3 Wire 20A Industrial Watertight Locking Plug, L6-20R, 250V, Black & White, HBL2323SW
$141.68 each
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Compare
Product Image of 2 Pole, 3 Wire, 480 VAC, 20 Amp, NEMA L16-20R, Self-Grounding Receptacle, Gray, HBL2430AR
$75.63 each
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Compare
Product Image of 3/4" Press Run x PEX Crimp Pro-Pal Multi-Port Tee w/ Drain
$88.92 each
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Compare
Product Image of 60 Second Open & 8 Second Close Hydramotor Actuator (120V)
$4,765.52 each
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Compare
Product Image of Straight Blade Duplex Receptacle, NEMA 5-20R, 20A, Self-Grounding, Gray, HBL5352GY
$42.24 each
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Compare
Product Image of Metal Raceway Utility Box, 1-Gang, HBL500/700/750 Series, Ivory, HBL57242IVA
$33.44 each
In Stock
Get 1 by Tue, Dec 1 - Wed, Dec 2
In Stock
Get 1 by Tue, Dec 1 - Wed, Dec 2
Compare
Product Image of 10' Long x 0.85" Deep x 0.76" Wide Metal Raceway, Ivory, HBL75010IV
$44.25 each
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Compare
Product Image of 3P 20A Industrial Locking Plug, L16-20R, 480V, Black & White, HBL2433
$84.93 each
In Stock
Get 20 by Tue, Dec 1 - Wed, Dec 2
In Stock
Get 20 by Tue, Dec 1 - Wed, Dec 2
Compare
Product Image of 20A Industrial Locking Plug, L22-20R, 277 & 480V, Black & White, HBL2523
$93.07 each
In Stock
Get 5 by Tue, Dec 1 - Wed, Dec 2
In Stock
Get 5 by Tue, Dec 1 - Wed, Dec 2
Compare
Product Image of 125/250 VAC, 30 Amp, L14-30P NEMA, Self Grounding Inlet, HBL2715SW
$225.95 each
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Compare
Product Image of 250 VAC, 30 Amp, L15-30R NEMA, Self Grounding Receptacle, Gray, HBL2720SR2
$114.66 each
In Stock
Get 5 by Tue, Dec 1 - Wed, Dec 2
In Stock
Get 5 by Tue, Dec 1 - Wed, Dec 2
Compare
Product Image of 3P 30A Industrial Locking Connector, L15-30R, 250V Female, Black & White, HBL2723SW
$196.99 each
In Stock
Get 2 by Tue, Dec 1 - Wed, Dec 2
In Stock
Get 2 by Tue, Dec 1 - Wed, Dec 2
Compare
Product Image of FZ02 3-Phase TEFC General Purpose Motor, 284T Frame (230V, 15 HP, 1185 RPM), H15T3B
$4,001.16 each
Backorder
Get it by Wed, Dec 30 - Tue, Feb 2
Backorder
Get it by Wed, Dec 30 - Tue, Feb 2
Compare
Product Image of Auxiliary Contact Kit for Unfused Disconnect Switches, Normally Closed, HBLAC1
$85.63 each
In Stock
Get 5 by Tue, Dec 1 - Wed, Dec 2
In Stock
Get 5 by Tue, Dec 1 - Wed, Dec 2
Compare
Product Image of 3P 30A Industrial Locking Plug, L17-30P, 600V Male, Black & White, HBL2741SW
$212.98 each
In Stock
Get 5 by Tue, Dec 1 - Wed, Dec 2
In Stock
Get 5 by Tue, Dec 1 - Wed, Dec 2
Compare
Product Image of Single Pole Male Connector, Double Set Screw, 400A, 250 VDC/600 VAC, AWG 2/0, White, HBL400MW
$68.04 each
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Compare
Product Image of Weatherproof Cover, 1-Gang, 1 Toggle, PBT, Gray, HBL5201
$67.48 each
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Backorder
Get it by Tue, Dec 29 - Thu, Jan 28
Compare
Product Image of Heat Exchanger Kit - 5350-6350, H000022
Heat Exchanger Kit - 5350-6350, H000022
SKU: H000022
Raypak
SKU: H000022
Brand: Raypak
$4,428.34 each
Backorder
Get it by Wed, Dec 30 - Tue, Feb 2
Backorder
Get it by Wed, Dec 30 - Tue, Feb 2
Resources
FAQs, Manuals & Videos
Articles
More About Wilo Z-15 Pump Parts

Wilo Z-15 pump parts are the replacement components contractors use to service and rebuild Z-15 wet-rotor circulator pumps found in residential and light commercial hydronic heating and hot water recirculation systems. The Z-15 is a single-speed, in-line circulator, and its most commonly replaced parts are the pump head, rotor and impeller assembly, and the mounting gaskets that seal the pump body to the piping flanges. Over years of continuous operation, mineral buildup and worn bearings inside the wet-rotor cartridge are the usual reasons a Z-15 needs a rebuild rather than a full replacement. Keeping gaskets, cartridges, and mounting hardware on hand lets a contractor return a system to service the same day instead of waiting on a full pump swap, which matters most on boiler systems where extended downtime affects a building's heat.

Subcategories

  • Pump Heads: Pump heads house the motor and electrical connections for the Z-15 circulator and bolt directly onto the wet-rotor cartridge below. Contractors replace a pump head when the motor windings fail or a bad capacitor stops the rotor from starting, rather than swapping the entire unit. Because the head separates from the wet end without draining the whole system in most installations, it's often the fastest single-part repair on a Z-15. Matching the voltage and speed rating to the original nameplate keeps the replacement head compatible with the existing wiring.
  • Rotor & Impeller Assemblies: The rotor and impeller assembly is the wet-rotor cartridge that spins inside the pump body to move water through the system. Mineral scale and sediment are the most common causes of a sluggish or seized rotor, especially in older cast iron hydronic loops. Replacing the assembly restores full flow without needing to replace the pump housing or motor head. A worn sleeve bearing inside the assembly is usually what causes the humming or grinding noise contractors hear before a Z-15 fails outright.
  • Mounting Gaskets & Flanges: Mounting gaskets seal the pump body against the flanges that connect it to the supply and return piping. A worn or improperly seated gasket is one of the most common sources of a slow weep leak at the pump union. Flanges themselves rarely need replacement unless they've been damaged during a prior installation or corroded from years of exposure to boiler water. Keeping the correct gasket size on hand avoids a return trip when a routine pump service uncovers a leak at the union.
  • Cartridge Seal Kits: Cartridge seal kits bundle the O-rings and shaft seals needed to reseal the wet-rotor cartridge after it's opened for cleaning or bearing replacement. Using a complete kit instead of individual seals reduces the chance of missing a small O-ring that causes a repeat callback. Seal kits are typically sized to the specific cartridge generation, so matching the kit to the pump's production era matters more than matching it to the overall Z-15 model name alone. A fresh seal kit is standard practice any time the cartridge is removed for service, even if the old seals look intact.
  • Buying Guide

    When sourcing Wilo Z-15 pump parts, start with the failure symptom rather than guessing at a full parts list. A pump that hums but doesn't spin usually points to a seized rotor or worn bearing, calling for a rotor and impeller assembly rather than a new pump head. A pump that won't start electrically, or trips a breaker, more often points to the motor windings or capacitor inside the pump head itself. Confirm the exact age and cartridge generation of the installed unit before ordering, since Wilo has updated the internal cartridge design over the years and parts from a newer cartridge don't always fit an older pump body. For jobs where the pump has been in continuous service for many years, rebuilding with a full cartridge seal kit alongside the rotor assembly is often more efficient than replacing components piecemeal, since it addresses wear across the whole wet end in one visit. Keep a small stock of the most commonly needed Wilo Z-15 pump parts, gaskets, seal kits, and a spare pump head, on hand for routine hydronic service calls, since these are the components most likely to fail from years of continuous operation. For a pump that's failed catastrophically or is several rebuilds in already, replacing the entire unit is often the more practical long-term choice over continuing to source individual parts.

    Frequently Asked Questions

    How do I know if my Wilo Z-15 needs a new pump head or a full rotor assembly?

    If the pump is silent and doesn't spin at all, check the motor head first, since that usually points to a failed capacitor or burned winding. If the pump hums or vibrates but the rotor won't turn, the wet-rotor cartridge itself is more likely the problem. Testing continuity at the motor terminals before ordering parts helps confirm which component actually failed.

    Can I rebuild a Z-15 without draining the whole heating system?

    In most installations, the pump head separates from the wet-rotor cartridge without opening the main piping, so a motor swap doesn't require draining the loop. Replacing the cartridge, gaskets, or flanges does require isolating and draining the pump section, though the rest of the system can often stay filled if isolation valves are present. Always confirm the specific installation has isolation valves before promising a no-drain repair.

    Why does my Z-15 keep leaking at the union even after a new gasket?

    A repeat leak after a gasket replacement is usually a sign the flange itself is corroded, warped, or wasn't torqued evenly during installation. Overtightening a new gasket can also distort it and cause the same leak to return. Checking the flange surface for pitting and torquing bolts in a cross pattern typically resolves a recurring union leak.

    How long does a Z-15 cartridge seal kit typically last?

    Seal life depends heavily on water quality and how often the system cycles, so there's no single fixed interval for every installation. Systems with harder water or more mineral content tend to wear seals faster than closed loops with treated water. Replacing the seal kit any time the cartridge is opened for service, rather than waiting for a visible leak, helps avoid a repeat callback.

    Is it worth rebuilding an older Z-15 or should I replace the whole pump?

    A rebuild makes sense when the pump body and flanges are still in good condition and only the wet-rotor cartridge or motor head has failed. Once a pump has needed several rebuilds over a short period, or the housing itself shows corrosion, replacing the entire unit is usually the more practical option. Weighing the age of the installation against the parts already on hand helps make that call quickly during a service visit.