Description

The Motorized Valve Actuator (MVA) (24VAC) features quick-opening motorized valve head that mounts directly onto 1-1/4" Brass and TruFLOW Valved Manifolds. The open/close indicator allows for easy visual inspection. It provides individual flow control on a multi-zoned manifold (manifold serving more than one zone). MVA includes end switch for activation of relay (pump), heat plant or other auxiliary devices. Power-open, spring-closed, do not mount actuators upside down.
Note: The MVA is not compatible with the Wirsbo Genius control system.

Specs

Application:

Zoning

Voltage:

24V

Operating Range:

24V +/- 10% VAC

Max Close-Off PSI:

17 psi/39.2 feet of head

Wiring:

Four-Wire

Type:

Motorized

Max Number of Actuators:

6 MVAs (50VA transformer)

9 MVAs (75VA transformer)

12 MVAs (100VA transformer)

Used With:

TruFLOW Manifolds

Current Draw Range:

0.29 Amps

Contact

Help Face
CALL US
Question? Call or text 888-757-4774
+
Help Face

Questions?

Speak with a real person who will go out of the way to help!
Call or text 888-757-4774
MondayThursday
8am7:45pm
Friday
9am7:45pm
SaturdaySunday
9am5:45pm


Product Reviews

4.41 out of 22 reviews
95% would recommend this product
4.41
out of 22 Reviews
95% would recommend this product
WRITE A REVIEW
5 star
68%
4 star
18%
3 star
5%
2 star
5%
1 star
5%
WRITE A REVIEW

Most Liked Positive Review

Wirsbo MVA have good track record

We have radiant floor heating in 23 homes. Each home uses one Wirsbo MVA for each heating zone. With an average of 4 per home have a total of about 100 heating zones thus 100 valves. The system was installed 11 years ago. Over the last 5 years we have replaced 10 Wirsbo MVA's. I expect to replace a few each season. When they die they tend to stay open so the heat runs constantly. We keep 3 in stock at all times. They take about 10 minutes to install. No need to call the plumber. 90% of the valves have been working for over 10 years. I think that's pretty good. We'll replace as necessary. I'd love it if they would work forever but I guess I need to be real about this.
VS

Most Liked Negative Review

Easy to install

I use the product as part of my home heating system. The valves are easy to replace and the price from Pex Supply is the best around. Unfortunately the valves need replacing about every two to three years. I don't think they're sealed and internal corrosion makes them malfunction.
Showing 1-10 of 22 reviews

Be prepared to replace every 2-3 years

Works fine but have to replace every 2-3 years.
Jim
PA
11 years ago
Was this review helpful to you?

MVA for Radiant Heating

Used for zone control in a radiant heating system with 8 MVA valves. All valves have been replaced once. We are now starting to replace the last Wirsbo's with the blue Uponor's. System is 15 years old this October. The MVA's work good for about 5-7 years. Then the small motors begin to fail or the end switch to the pump fails closed.
donmac
Whidbey Island, Washington
13 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

they work like they are supposed to

easy to use easy to trouble shoot
swede
hot springs village arkansas
13 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Very good product.

Product works very well.
Mal
Newaygo, MI
13 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Quick acting

Works great, replacement for a MVA with bad end switch so we will see.
Sears6341
Beecher Il
13 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Valve Actuator

simple screw it on, hook up 4 wires. 2 min time floor heat is up and running, floor is worm again, saved a pile of money
Hillbilly
outback Mn.
13 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Fills the bill.

One of the motorized valve actuators in our heating system failed. I ordered this part as a replacement and it works perfectly.
Steve
Montrose, CO
13 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Just like picture, different color is al

This was a easy replacement would recommend to any homeowner.
Vic
Orcas Island WA
14 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Purchase process was great...

The system works great but more important is the quality follow up processes if your need replacement parts. There are real people who talk to you that help you with technical questions, installation adjustments, who will call you back when there are upgrades. All done quickly, they know that time is important and respect you time. They are great....
Walt
Ocean City, MD
14 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

PexSupply exceeded ecpectations.

Installation is simple and straight forward. The directions mention that the manifolds should be balanced. It would have been helpful to have instructions on how to balance the manifolds - I'm a handy homeowner, not an experienced radiant floor installer.
Fred G. (for great) Sanford
Loveland, CO
14 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Product Q&A

14 Questions
14 Questions
ASK A QUESTION

Q: I am a DYI homeowner, my systemis 10-years old. THere are a couple of rooms where the radiant heat seems to be "hot" all the time, is there a way to test to see if the actuator is bad or if I have other problems. Thanks

Asked by 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

You can always check the actuator with a zone meter to see if the unit is opening and closing based on a call for heat.

Was this review helpful to you?
- takman67

Sure, just look at the front of the actuator. If the needle on the valve is in the open position all the time, just disconnect one set of the red and yellow wires from the thermostat connection. If the valve stays open replace it. If it closes, then reopens when you reconnect the themostat wires, your themostat may need replacing.

Was this review helpful to you?

Q: I am a DIY homeowner and have a faulty MVA on a 7 valve manifold. It seems like I should be able to replace the MVA myself but before I order parts I would like to know where I can find installation info for the MVA. I prefer to be knowledgeable about a task before spending money on materials and then realize I am in over my head. Can you provide a link where I can get install info for the A3020522 MVA? Thanks

Asked by DIYinNM 16 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Please take a look at this document: http://s3.pexsupply.com/manuals/1291296857222/42040_PROD_FILE.pdf

Was this review helpful to you?

Q: how do I know wether I can use SKU 3010522 or 3020522 or 3020416 for replacements on my existing system. I have a mix of both types of units now.

Asked by 16 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

The A3010522 is a thermal 4 wire unit and is slow opening (about 3-5 mins. to fully open), the A3020522 is a motorized 4 wire unit and is fast acting (opens in about 4 secs.), and the the A3020416 is a thermal 2 wire unit and is slow opening (about 3-5 mins. to fully open). All three are actuators and do the same thing as the end result, but each does it differently. So you can use any of them, it just depends on how you want it done.

Was this review helpful to you?

Q: Trying to put together a 10 loop heating system. Is the manifold # * A2641000 * Brand: Wirsbo (Uponor) compatible with tthis actuator? Could you help me with putting together a list of necessary items in addition to the manifold listed above to make my setup complete. I will be using 5/8 hePex plus for this setup, that i have already purchased from you guys. Thank you in advance for your help.

Asked by 16 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

The 10 loop manifold A2641000 is compatible with this actuator, A3020522. Two components you will definitely need are fitting assemblies (20) A4020625 to connect the PEX loops to the manifold and supply/return adapters. The other necessary components will depend on your system setup. Some common system components include pump, switching relay, transformer, and thermostats.