Crimp style manifolds are copper or brass distribution units that split a single water supply line into multiple PEX branch lines using crimped connections rather than push-fit or threaded joints. Manufacturers offer these manifolds with up to 15 circuits and trunk sizes ranging from 1 inch to 2 inches, giving installers flexibility for jobs ranging from a small bathroom remodel to a full radiant heating system. Plumbers and radiant heat installers choose crimp style manifolds when they want a permanent, low-maintenance connection that won't loosen over time the way some mechanical fittings can. Selecting the right port count and trunk size up front keeps a plumbing or hydronic system balanced and easy to service down the road.
Subcategories
Buying Guide
Start with port count. Crimp style manifolds are available with anywhere from a couple of branches up to 15 circuits, so match the port count to the number of fixtures or radiant loops the system needs to serve, with a little room to spare for future additions.
Next, confirm trunk size. Manifold trunks typically come in 1-inch, 1-1/4-inch, 1-1/2-inch, and 2-inch diameters, and the right size depends on the total flow demand running through the manifold. A trunk that's too small can restrict flow and cause pressure drop across multiple fixtures running at once.
Decide whether valved ports make sense for the job. A manifold with individual shutoff valves lets a plumber isolate one branch for repair without draining the whole system, which is especially useful in multi-bathroom homes or buildings with many zones. Non-valved manifolds cost less and work fine for simpler installations where isolating individual runs isn't a priority.
Check barb size compatibility last. Crimp style manifolds accept different barb sizes, commonly 3/8-inch through 3/4-inch, and the crimp rings used to attach PEX tubing must match that barb size exactly to form a reliable seal. Confirming barb size and crimp ring compatibility before ordering avoids a mismatched connection at rough-in.
Frequently Asked Questions
How many ports can a crimp style manifold have?
Crimp style manifolds are available with a wide range of port counts, with some manufacturers offering configurations from a couple of branches up to 15 circuits. The right count depends on how many fixtures or radiant heat loops the manifold needs to feed.
What trunk sizes are available for crimp style manifolds?
Trunk sizes commonly run from 1 inch up to 2 inches in diameter. Larger trunks handle higher flow demand, so the choice depends on the total number of branches and fixtures the manifold serves at once.
What's the difference between valved and non-valved crimp manifolds?
Valved manifolds include a shutoff valve at each branch port, letting a plumber isolate one line for repair without shutting down the entire system. Non-valved manifolds skip the individual valves, which lowers cost and works fine for simpler installations where isolating branches isn't necessary.
Can crimp style manifolds be used for radiant floor heating?
Crimp style manifolds are commonly used for radiant heat installations, often ordered as matched supply and return pairs to feed multiple floor loops from one location. These hydronic manifolds are typically factory pressure tested before they ship.
What crimp ring size do I need for a crimp style manifold?
The crimp ring size must match the barb size on the manifold port, which is commonly available in 3/8-inch, 1/2-inch, 5/8-inch, or 3/4-inch. Using a mismatched crimp ring size will prevent a proper seal at the connection.