Apply to be a TradeMaster!
Filter menu expanded

Filters

1,221 items
Reset

SORT

Product Availability
–

Show In Stock Only (593)

Amperage
–

2.5 (2)
3 (2)
5 (4)
6 (2)
7 (5)
9 (29)
10 (17)
12 (21)
15 (3)
17 (1)

Voltage
–

12v (1)
12-250 V (1)
24 VAC (4)
24 VDC (4)
24-240V AC/DC (1)
24V (183)
36V (1)
50-129V AC/DC (1)
100V (1)
110v (69)

Poles
–

1 (77)
1.5 (15)
2 (161)
3 (475)
4 (53)
5 (1)
6 (6)
8 (5)
10 (2)
12 (2)

Review Score
–

(97)
(8)
(3)
(2)

Price Range
–

$5 to $10 (11)
$10 to $15 (50)
$15 to $20 (46)
$20 to $25 (52)
$25 to $30 (41)
$30 to $35 (61)
$35 to $40 (78)
$40 to $45 (51)
$45 to $50 (27)
$50 to $60 (69)

Electrical Contactors

Help Face
Need a little help?
1221 items
Grid
List
Compare
Product Image of Contactor Enclosure For Class 8910 Type DPA14/DPA24/DPA34/DPA44/DPA52/DPA53 Contactor, 9991DPG2
$94.09 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 120V, 80 Amp Contactor
120V, 80 Amp Contactor
SKU: 3RT1045-1AK60
Siemens
SKU: 3RT1045-1AK60
Brand: Siemens
$325.02 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of Contactor Suppressor Module for LC1D40A-D65A, LC1DT60A-DT80A and TeSys D, LAD4V3G
$35.65 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 12 Pole N/O Mechanically Held Lighting Contactor, NEMA 1 (30A, 600V, 110/120VAC Coil), 8903LXG1200V02
$1,527.19 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of Contactor Auxiliary Contact Block for CR1F, TeSys D and TeSys F, LADN40
$61.40 each
In Stock
Get 2 by Mon, Oct 5 - Tue, Oct 6
In Stock
Get 2 by Mon, Oct 5 - Tue, Oct 6
Compare
Product Image of 2 Pole N/O Definite Purpose Contactor, 60A (480V)
2 Pole N/O Definite Purpose Contactor, 60A (480V)
SKU: 8910DPA62V14
Square D
SKU: 8910DPA62V14
Brand: Square D
$340.62 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of TeSys D IEC Non-Reversing Contactor (25A Inductive/40A Resistive, 120V AC Coil, 4P (2 NO+2 NC))
$309.70 each
In Stock
Get 5 by Mon, Oct 5 - Tue, Oct 6
In Stock
Get 5 by Mon, Oct 5 - Tue, Oct 6
Compare
Product Image of 3 Pole Contactor, NC & NO 24VDC, TeSys Deca, LC1D093BL
$176.10 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 80 to 95 Amp, Contactor Coil for LC1D80, LC1D95 and TeSys D, LX1D6T6
$58.48 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of Magnetic Contactor/Starter Contact Kit, Starter Size 3, Three Poles
$893.24 each
In Stock
Get 1 by Fri, Oct 2
In Stock
Get 1 by Fri, Oct 2
Compare
Product Image of Contactor Suppressor Module for LC1D09-D38, LC1DT20-DT40, LP1D80, LP1D80-D115 and TeSys D, LA4DE2U
$35.03 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 2NO/2NC Auxiliary Contact, Side Mount, 49AB22
$447.56 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 208/230 Vac 3 Pole PowerPro Deluxe Definite Purpose Contactor w/ Lug Connectors, DP3075C5015
208/230 Vac 3 Pole PowerPro Deluxe Definite Purpose Contactor w/ Lug Connectors, DP3075C5015
SKU: DP3075C5015
Resideo
SKU: DP3075C5015
Brand: Resideo
$317.90 each
In Stock
Get 3 by Fri, Oct 2
In Stock
Get 3 by Fri, Oct 2
Compare
Product Image of Varistor Surge Suppressor for Mounting to Contactor
Varistor Surge Suppressor for Mounting to Contactor
SKU: 3RT2926-1BB00
Siemens
SKU: 3RT2926-1BB00
Brand: Siemens
$23.92 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 50 Amp 3-Pole NC & NO 24VDC IEC Contactor, LC1D50ABD
$416.39 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of Contact Repair Kit, NEMA Sz 3
Contact Repair Kit, NEMA Sz 3
SKU: 75HF14
Siemens
SKU: 75HF14
Brand: Siemens
$342.79 each
In Stock
Get 5 by Fri, Oct 2
In Stock
Get 5 by Fri, Oct 2
Compare
Product Image of 3 Pole Definite Purpose Starter, Enclosed (30A, 1PH, 208-240/220VAC Coil), 8911DPSG33V09
$549.07 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 3 Pole Contactor, NC & NO 120Vac at 50/60 Hz, Reversible, TeSys Deca, LC2D18G7V
$456.61 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 40 Amp 3-Pole NC & NO 220VAC 50/60 Hz IEC Contactor, LC1D40AM7
$352.89 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of Non-Reversing Oversized Contactor & Motor Starter Enclosure for NEMA Size 00, 0, 1 (Type S, 3A, NEMA 1), 9991SCG1
$331.19 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 1-Pole Definite Purpose Contactor (277V, 30 Amp)
1-Pole Definite Purpose Contactor (277V, 30 Amp)
SKU: C25CNB130H
Eaton
SKU: C25CNB130H
Brand: Eaton
$63.60 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 2 Pole Normally Open Push Button Contact Block
$67.07 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of Auxiliary Switch for Titan Max Contactor SPDT & Position 2
$20.58 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 3-Pole XT IEC Non-Reversing Contactor, Full Voltage, Size K (120/110V, 73 Amp)
$1,087.40 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 150 Amp 3-Pole NC & NO 480VAC 50/60 Hz IEC Contactor, LC1D150T7
$997.35 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of Contactor Main Contact Set for LC1D115, LA5D1158031
$355.74 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 12 Amp 3-Pole NC & NO 110VAC 50/60 Hz Reversing IEC Contactor, LC2D12F7
$464.06 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of Contactor Contact Block for TeSys D, LADR4
$197.91 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 115 Amp 3-Pole NC & NO 24VDC IEC Contactor, LC1D115BD
$631.83 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 8 Pole N/O Electrically Held Lighting Contactor, NEMA 1 (30A, 600V, 277VAC Coil), 8903LG80V04
$1,368.71 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 120V 1NO/2NC Aux Switch, FP S00/S0
120V 1NO/2NC Aux Switch, FP S00/S0
SKU: 3RH2911-1HA12
Siemens
SKU: 3RH2911-1HA12
Brand: Siemens
$36.66 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 4NO 24VDC Contactor Relay, Size S00, Screw Terminal
4NO 24VDC Contactor Relay, Size S00, Screw Terminal
SKU: 3RH2140-1BB40
Siemens
SKU: 3RH2140-1BB40
Brand: Siemens
$144.14 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 4 Pole Contactor (208/240V, 30 Amp)
$58.59 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of Contactor Suppressor Block for LX1F Coils and LX9F Coils, LA9D09980
$32.10 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of Contactor Thermal Unit (Type CC, Melting Alloy, Class 20), CC143.0
$50.34 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 24V 68 Amp 3P Contactor, AF65-30-00-11
24V 68 Amp 3P Contactor, AF65-30-00-11
SKU: AF65-30-00-11
ABB
SKU: AF65-30-00-11
Brand: ABB
$406.57 each
In Stock
Get 1 by Fri, Oct 2
In Stock
Get 1 by Fri, Oct 2
Compare
Product Image of 4 Pole Contactor, NC & NO 120Vac at 50/60 Hz, Reversible, TeSys Deca, LC2DT25G7
$531.32 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 2NO Freedom Auxiliary Contact, Side Mount
2NO Freedom Auxiliary Contact, Side Mount
SKU: C320KGS5
Eaton
SKU: C320KGS5
Brand: Eaton
$56.48 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 1 N.O./1 N.C. Auxiliary Contact Block Contactor , 10A (690V)
$90.72 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of Contactor Thermal Unit, A1.86
Contactor Thermal Unit, A1.86
SKU: A1.86
Square D
SKU: A1.86
Brand: Square D
$34.71 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of Contactor Coil for LC1D09-D38, LC1DT20-DT40 and TeSys D, LXD1U7
$35.85 each
In Stock
Get 1 by Mon, Oct 5 - Tue, Oct 6
In Stock
Get 1 by Mon, Oct 5 - Tue, Oct 6
Compare
Product Image of 38 Amp, 240V IEC Contactor
38 Amp, 240V IEC Contactor
SKU: 3RT1033-1AC20
Siemens
SKU: 3RT1033-1AC20
Brand: Siemens
$164.63 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 12 Pole N/O Electrically Held Lighting Contactor, NEMA 1 (30A, 600V, 110/120VAC Coil), 8903LG1200V02
$1,681.36 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of Reversing Contactor Kit for LC1D40A-D65A and Reversing Contactor, LAD9R3
$84.74 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 12-24V Contactor Suppressor Module For LC1, LP1 And TeSys K, LA4KE1B
$18.56 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 3 Pole, 12 Amp, 480V Power Contactor
3 Pole, 12 Amp, 480V Power Contactor
SKU: 3RT2017-1AV61
Siemens
SKU: 3RT2017-1AV61
Brand: Siemens
$120.91 each
In Stock
Get 2 by Fri, Oct 2
In Stock
Get 2 by Fri, Oct 2
Compare
Product Image of Contactor Coil For 8910DPA, 9998DA2V06
Contactor Coil For 8910DPA, 9998DA2V06
SKU: 9998DA2V06
Square D
SKU: 9998DA2V06
Brand: Square D
$50.26 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Compare
Product Image of 3 Pole Contactor, NC & NO 24Vac at 50/60 Hz, TeSys Deca, LC1D40A6B7
3 Pole Contactor, NC & NO 24Vac at 50/60 Hz, TeSys Deca, LC1D40A6B7
SKU: LC1D40A6B7
Schneider Electric
SKU: LC1D40A6B7
$365.61 each
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Backorder
Get it by Thu, Oct 29 - Fri, Nov 27
Resources
FAQs, Manuals & Videos
Articles
More About Contactors

Contactors are electromechanical switches that use a low-voltage control signal to open and close a higher-voltage power circuit, most commonly the circuit that feeds a compressor, condenser fan motor, or other large HVAC or electrical load. A thermostat or control board sends a small signal to energize the contactor's coil, which pulls a set of contacts together and completes the high-voltage circuit without routing that heavier current through the control wiring itself. HVAC technicians replace contactors more often than almost any other electrical component in a split system, since the contacts see repeated arcing every time the compressor or fan cycles on and off. A pitted, burned, or stuck contactor is a common cause of equipment that will not start, that hums without running, or that keeps running after the thermostat is satisfied. Contactors are sized by coil voltage, number of poles, and current rating, and matching all three to the application is what keeps a replacement working safely in place of the original.

Subcategories

  • Single-Pole Contactors: Single-pole contactors switch one leg of the power circuit while the other leg stays connected directly, a configuration common on smaller residential condensing units and single-phase loads. They cost less and take up less panel space than multi-pole versions, which makes them a common original-equipment choice on lighter-duty equipment. Technicians confirm the coil voltage and current rating match the original part before swapping one in, since an undersized contactor will fail quickly under the same load. Single-pole units are typically the most frequently replaced contactor type on residential service calls.
  • Double-Pole and Two-Pole Contactors: Double-pole contactors switch both legs of a two-wire power circuit simultaneously, fully disconnecting the load rather than leaving one leg energized. This configuration is common on larger residential and light commercial condensing units where fully isolating the compressor circuit is the standard design approach. Replacing a double-pole contactor with a single-pole unit is not a safe substitution even if the coil voltage matches, since the circuit design depends on both legs switching together. Technicians check the original wiring diagram when the pole configuration is not obvious from the failed part alone.
  • Three-Pole Contactors: Three-pole contactors switch all three legs of a three-phase power circuit, a configuration used almost exclusively on commercial and light industrial HVAC equipment rather than typical residential split systems. Failure symptoms mirror single and double-pole units, including pitted contacts, a stuck armature, or a coil that no longer pulls in reliably. Because three-phase equipment often carries higher current loads, three-pole contactors are built with heavier contact material to handle the added electrical stress. Matching current rating and coil voltage remains the deciding factor when selecting a replacement, the same as with lower pole-count contactors.
  • Definite Purpose Contactors: Definite purpose contactors are built specifically for a narrow range of applications, most often HVAC compressor and fan loads, rather than the broader industrial control uses that a general-purpose contactor covers. Their compact size and simplified mounting make them the standard choice for residential and light commercial condensing unit replacement work. Technicians stock definite purpose contactors in the most common voltage and pole configurations since these cover the large majority of service calls. Choosing a definite purpose model built for the specific application avoids paying for features meant for industrial control panels that a condensing unit will never use.

Buying Guide

Matching a replacement contactor to the failed original starts with three specifications: coil voltage, number of poles, and full-load or resistive current rating. Coil voltage refers to the low-voltage signal that energizes the contactor, commonly a value supplied by the control transformer, and it needs to match exactly since a contactor with the wrong coil voltage either will not pull in or will burn out quickly from overvoltage. Pole count determines how many legs of the power circuit the contactor switches, and current rating determines how much load the contacts can handle without excessive arcing or premature failure.

Physical size and terminal configuration matter for a clean installation, since Contactors mount inside a tight electrical compartment where a slightly larger or differently shaped replacement may not fit the existing bracket or wiring layout without modification. Comparing the physical footprint of a proposed replacement against the failed part before ordering avoids a return trip when the new contactor does not clear the panel enclosure.

Technicians working service routes across a mix of residential and light commercial equipment generally keep the most common single-pole and double-pole configurations on the truck, since these cover the majority of everyday calls. Three-pole contactors and less common voltage combinations are usually ordered once the specific unit's requirements are confirmed on site rather than stocked in bulk, since commercial three-phase equipment makes up a smaller share of most residential-focused service work.

Frequently Asked Questions

What are the signs that a contactor needs to be replaced?

A unit that hums but will not start, a compressor or fan that keeps running after the thermostat is satisfied, or visible pitting and burn marks on the contacts all point toward a failing contactor. A contactor that chatters or buzzes audibly when energized is also a common warning sign. Testing the coil for continuity and checking the contacts for excessive wear confirms the diagnosis before ordering a replacement.

How is coil voltage different from the contactor's power circuit voltage?

Coil voltage is the low-voltage signal, typically supplied through the control transformer, that energizes the contactor and pulls the contacts together. The power circuit voltage is the separate, usually much higher, voltage that the contacts switch on and off to run the compressor or fan motor. Both values need to be checked separately since matching one without the other will not produce a working replacement.

Can a single-pole contactor be replaced with a double-pole model?

A double-pole contactor can generally replace a single-pole unit as long as coil voltage and current rating match, since the extra pole simply switches the additional leg without disconnecting anything unusual. The reverse substitution, replacing a double-pole contactor with a single-pole unit, is not safe since it leaves one leg of the circuit energized when it should be fully disconnected. Checking the original wiring diagram before making the swap avoids this mistake.

Why do HVAC contactors fail more often than other electrical components?

Contactors switch a large electrical load every time the compressor or fan cycles on and off, and that repeated arcing gradually wears down the contact material until the connection becomes unreliable. Units that cycle frequently, such as during a hot summer with heavy air conditioning use, put more cumulative wear on the contactor than equipment that runs for longer, less frequent cycles. This wear pattern makes contactors one of the most commonly replaced parts in HVAC service work.

Is it safe to bypass a failed contactor temporarily?

Bypassing a contactor removes the low-voltage control point that allows the thermostat to safely start and stop the compressor or fan, which creates both a safety hazard and a risk of equipment damage from uncontrolled operation. A temporary bypass is not a substitute for a proper repair and should not be left in place beyond diagnosing the fault. Replacing the failed contactor with a correctly matched part is the only reliable fix.